A general dual-bolus approach for quantitative DCE-MRI

被引:29
作者
Kershaw, Lucy E.
Cheng, Hai-Ling Margaret [1 ,2 ]
机构
[1] Hosp Sick Children, Dept Diagnost Imaging, Res Inst & Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Dual bolus; Prebolus; DCE-MRI; TRICKS; AIF; CONTRAST-ENHANCED MRI; TISSUE HOMOGENEITY MODEL; MYOCARDIAL-PERFUSION; BLOOD-FLOW; SINGLE-BOLUS; T-1;
D O I
10.1016/j.mri.2010.08.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a dual-bolus technique for quantitative dynamic contrast-enhanced MRI (DCE-MRI) and show that it can give an arterial input function (AIF) measurement equivalent to that from a single-bolus protocol. Methods: Five rabbits were imaged using a dual-bolus technique applicable for high-resolution DCE-MRI, incorporating a time resolved imaging of contrast kinetics (TRICKS) sequence for rapid temporal sampling. AIFs were measured from both the low-dose prebolus and the high-dose main bolus in the abdominal aorta. In one animal, TRICKS and fast spoiled gradient echo (FSPGR) acquisitions were compared. Results: The scaled prebolus AIF was shown to match the main bolus AIF, with 95% confidence intervals overlapping for fits of gamma-variate functions to the first pass and linear fits to the washout phase, with the exception of one case. The AIFs measured using TRICKS and FSPGR were shown to be equivalent in one animal. Conclusion: The proposed technique can capture even the rapid circulation kinetics in the rabbit aorta, and the scaled prebolus AIF is equivalent to the AIF from a high-dose injection. This allows separate measurements of the AIF and tissue uptake curves, meaning that each curve can then be acquired using a protocol tailored to its specific requirements. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:160 / 166
页数:7
相关论文
共 19 条
[1]  
Brookes JA, 1999, JMRI-J MAGN RESON IM, V9, P163, DOI 10.1002/(SICI)1522-2586(199902)9:2<163::AID-JMRI3>3.0.CO
[2]  
2-L
[3]   T1 measurement of flowing blood and arterial input function determination for quantitative 3D T1-weighted DCE-MRI [J].
Cheng, Hai-Ling Margaret .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (05) :1073-1078
[4]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[5]   Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method [J].
Christian, Timothy F. ;
Aletras, Anthony H. ;
Arai, Andrew E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) :1271-1277
[6]   pO2 and regional blood flow in a rabbit model of limb ischemia [J].
Grinberg, OY ;
Hou, HG ;
Grinberg, SA ;
Moodie, KL ;
Demidenko, E ;
Friedman, BJ ;
Post, MJ ;
Swartz, HM .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (03) :659-670
[7]   Temporal sampling requirements for the tracer kinetics modeling of breast disease [J].
Henderson, E ;
Rutt, BK ;
Lee, TY .
MAGNETIC RESONANCE IMAGING, 1998, 16 (09) :1057-1073
[8]   Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans [J].
Hsu, LY ;
Rhoads, KL ;
Holly, JE ;
Kellman, P ;
Aletras, AH ;
Arai, AE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) :315-322
[9]   Precision in measurements of perfusion and microvascular permeability with T1-weighted dynamic contrast-enhanced MRI [J].
Kershaw, Lucy E. ;
Buckley, David L. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :986-992
[10]   Benign Prostatic Hyperplasia: Evaluation of T1, T2, and Microvascular Characteristics With T1-Weighted Dynamic Contrast-Enhanced MRI [J].
Kershaw, Lucy E. ;
Hutchinson, Charles E. ;
Buckley, David L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (03) :641-648