Comparative study of SmartAmp assay and reverse transcription-polymerase chain reaction by saliva specimen for the diagnosing COVID-19

被引:5
作者
Asai, Nobuhiro [1 ,2 ,3 ]
Nakamura, Akiko [1 ,2 ]
Sakanashi, Daisuke [1 ,2 ]
Koita, Isao [1 ,2 ]
Ohashi, Wataru [4 ]
Kawamoto, Yuzuka [1 ,2 ]
Miyazaki, Narimi [1 ,2 ]
Ohno, Tomoko [1 ,2 ]
Yamada, Atsuko [1 ,2 ]
Chida, Sumie [1 ,2 ]
Shibata, Yuichi [1 ,2 ]
Shiota, Arufumi [2 ]
Kato, Hideo [1 ,5 ,6 ]
Hagihara, Mao [1 ,7 ]
Yamagishi, Yuka [1 ,2 ]
Ohta, Hirotoshi [1 ,2 ]
Mikamo, Hiroshige [1 ,2 ]
机构
[1] Aichi Med Univ Hosp, Dept Clin Infect Dis, Nagakute, Aichi, Japan
[2] Aichi Med Univ Hosp, Dept Infect Control & Prevent, Nagakute, Aichi, Japan
[3] Univ Michigan, Dept Pathol, Ann Arbor, MI 48109 USA
[4] Aichi Med Univ Hosp, Clin Res Ctr, Div Biostat, Nagakute, Aichi, Japan
[5] Mie Univ Hosp, Dept Pharm, Tsu, Mie, Japan
[6] Mie Univ, Dept Clin Pharmaceut, Div Clin Med Sci, Grad Sch Med, Tsu, Mie, Japan
[7] Aichi Med Univ, Dept Mol Epidemiol & Biomed Sci, Nagakute, Aichi, Japan
关键词
SmartAmp; COVID-19; SARS-CoV-2; Reverse transcription-polymerase chain reaction; Coronavirus;
D O I
10.1016/j.jiac.2021.09.011
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Introduction: The pandemic of a novel coronavirus disease 2019 (COVID-19) caused by a severe acute respiratory coronavirus 2 (SARS-CoV-2) infection has been problematic worldwide. A new SARS-CoV-2 diagnostic test (SmartAmp) was licensed in Japan in July 2021. This method, which enables us to diagnose COVID-19 as well as a gene mutation on the virus, is promising to reduce medical costs and staff labor Patients and methods: To analyze the diagnostic accuracy of the SmartAmp assay for diagnosing COVID-19, we performed this retrospective study at our institute during April and May 2021. We compared the results of the SmartAmp assay and real-time reverse transcription-polymerase chain reaction (rRT-PCR) using a saliva sample from individuals suspected as having COVID-19. Results: Out of 70 samples tested, the SmartAmp assay had 50 (71%) positive and 20 (29%) negative results. Using rRT-PCR as a reference, the diagnostic accuracy displayed a sensitivity of 84%, a specificity of 95%, a positive predictive value of 97.7%, and a negative predictive value of 70.4%. On the other hand, false-negative cases were found in 7 (10%), and there was no significant difference of Ct-value between true positive and false negative cases (Mean Ct-value 25.2 vs. 27.5 cycles, p = 0.226 by Mann-Whitney U test). Conclusion: The SmartAmp assay is a valuable method to diagnose COVID-19 rapidly. However, the negative predictive value is not high enough to diagnose the disease, so that negative results should be considered for rRTPCR testing if patients are suspected of having COVID-19.
引用
收藏
页码:120 / 123
页数:4
相关论文
共 50 条
[41]   Screening of COVID-19 polymerase chain reaction tests using saliva for pregnant women and their partners in Himeji city [J].
Okamura, Shinsuke ;
Akamatsu, Nobuo ;
Kitajima, Takashi ;
Nakabayashi, Koji ;
Fukumoto, Shun ;
Katayama, Takaaki ;
Mizutani, Yasushi ;
Kiyomoto, Hideyasu ;
Yamada, Hideto .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2021, 47 (04) :1253-1255
[42]   Real-time reverse transcription-polymerase chain reaction assay panel for the detection of severe acute respiratory syndrome coronavirus 2 and its variants [J].
Lu Rou-Jian ;
Zhao Li ;
Huang Bao-Ying ;
Ye Fei ;
Wang Wen-Ling ;
Tan Wen-Jie .
中华医学杂志英文版, 2021, 134 (17) :2048-2053
[43]   Real-time reverse transcription-polymerase chain reaction assay panel for the detection of severe acute respiratory syndrome coronavirus 2 and its variants [J].
Lu, Rou-Jian ;
Zhao, Li ;
Huang, Bao-Ying ;
Ye, Fei ;
Wang, Wen-Ling ;
Tan, Wen-Jie .
CHINESE MEDICAL JOURNAL, 2021, 134 (17) :2048-2053
[44]   Persistent Positive Real-Time Reverse Transcription Polymerase Chain Reaction (RT-PCR) Results in Recovered COVID-19 Hospital Patients: Implications for Interpretation [J].
Hur, Jian ;
Kim, Dong -Min ;
Park, Donghwi ;
Chang, Min Cheol .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
[45]   Exogenous reference gene normalization for real-time reverse transcription-polymerase chain reaction analysis under dynamic endogenous transcription [J].
Johnston, Stephen ;
Gallaher, Zachary ;
Czaja, Krzysztof .
NEURAL REGENERATION RESEARCH, 2012, 7 (14) :1064-1072
[46]   Exogenous reference gene normalization for real-time reverse transcription-polymerase chain reaction analysis under dynamic endogenous transcription [J].
Stephen Johnston ;
Zachary Gallaher ;
Krzysztof Czaja .
Neural Regeneration Research, 2012, 7 (14) :1064-1072
[47]   Reverse transcription-polymerase chain reaction in situ hybridization for SYT-SSX fusion gene transcripts in synovial sarcomas [J].
Kawauchi, S ;
Fukuda, T ;
Chochi, Y ;
Kondo, T ;
Oga, A ;
Sasaki, K .
INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2005, 16 (04) :763-766
[48]   Dynamics of Reverse Transcription-Polymerase Chain Reaction and Serologic Test Results in Children with SARS-CoV-2 Infection [J].
Tagarro, Alfredo ;
Jose Sanz-Santaeufemia, Francisco ;
Grasa, Carlos ;
Cobos, Elena ;
Yebra, Julia ;
Antonio Alonso-Cadenas, Jose ;
Baquero-Artigao, Fernando ;
Miguel Mesa-Guzman, Juan ;
Perez-Seoane, Beatriz ;
Calvo, Cristina ;
Luisa Herreros, Maria ;
Epalza, Cristina ;
Melendo, Susana ;
Dominguez-Rodriguez, Sara ;
Vidal, Paula ;
Pacheco, Monica ;
Ballesteros, Alvaro ;
Bernardino, Maria ;
Villanueva-Medina, Sara ;
Rodriguez-Molino, Paula ;
Miragaya Castro, Sandra ;
Riviere, Jacques ;
Garces, Rosa ;
Santiago, Begona ;
Fumado, Victoria ;
Urretavizcaya-Martinez, Maria ;
Luz Garcia-Garcia, Maria ;
Penin, Maria ;
Cava, Fernando ;
Saez, Elena ;
Isabel Iglesias-Bouzas, Maria ;
Herrero, Blanca ;
de Jesus Reinoso, Teresa ;
Moraleda, Cinta .
JOURNAL OF PEDIATRICS, 2022, 241 :126-132
[49]   High sensitivity analysis of gene expression in single embryonic somites using coupled reverse transcription-polymerase chain reaction [J].
James F. Sanzo ;
Rocky S. Tuan .
Molecular Biotechnology, 1998, 9 :7-15
[50]   Reverse transcription-polymerase chain reaction amplification of respiratory syncytial virus genome from neonatal nasal swab samples [J].
Yoshio, H ;
Yamada, M ;
Nii, S .
ACTA PAEDIATRICA JAPONICA, 1996, 38 (05) :429-433