Determination of rhodium and platinum by electrothermal atomic absorption Spectrometry after preconcentration with a chelating resin

被引:0
作者
Rojas, F. Sanchez [1 ]
Ojeda, C. Bosch [1 ]
Pavon, J. M. Cano [1 ]
机构
[1] Univ Malaga, Fac Sci, Dept Analyt Chem, E-29071 Malaga, Spain
关键词
rhodium; platinum; electrothermal atomic absorption spectrometry; preconcentration; flow injection;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The present publication describes a separation/preconcentration procedure for the subsequent trace analysis of rhodium and platinum in environmental samples. A chelating ion-exchange resin was employed for this purpose and an automatic on-line flow injection electrothermal atomic absorption spectrometry (FI-ET-AAS) method was used for the determination of trace amounts of Rh and Pt in different materials. The solutions are simultaneously treated and the ions determined sequentially. Detection limits of rhodium and platinum are 0.8 and 1.0 ng mL(-1), respectively. Linearity was obtained in the range 0-50 ng mL(-1) for rhodium and 0-100 ng mL(-1) for platinum. The relative standard deviations were 1.8% for 10 ng mL(-1) of Rh and 1.6% for 10 ng mL(-1) of Pt. Enrichment factors were 20 for Rh and 14 for Pt.
引用
收藏
页码:1270 / 1275
页数:6
相关论文
共 31 条
[1]   Methods for the determination of platinum group elements originating from the abrasion of automotive catalytic converters [J].
Bencs, L ;
Ravindra, K ;
Van Grieken, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (10) :1723-1755
[2]  
Canada Rudner P., 1998, Talanta, V46, P1095, DOI 10.1016/S0039-9140(97)00389-5
[3]   ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE PLATINUM BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
CANTARERO, A ;
GOMEZ, MM ;
CAMARA, C ;
PALACIOS, MA .
ANALYTICA CHIMICA ACTA, 1994, 296 (02) :205-211
[4]  
CHANG XJ, 1991, ANAL CHIM ACTA, V245, P13
[5]   DETERMINATION OF THE NOBLE-METALS IN CHROMITES AND OTHER GEOLOGICAL-MATERIALS BY RADIOCHEMICAL NEUTRON-ACTIVATION ANALYSIS [J].
COCHERIE, A ;
VOLFINGER, M ;
MEYER, G .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 113 (01) :133-143
[6]   Preconcentration and matrix separation of precious metals in geological and related materials using metalfix-chelamine resin prior to inductively coupled plasma mass spectrometry [J].
Coedo, AG ;
Dorado, MT ;
Padilla, I ;
Alguacil, F .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :31-40
[7]   Levels and risk assessment for humans and ecosystems of platinum-group elements in the airborne particles and road dust of some European cities [J].
Gómez, B ;
Palacios, MA ;
Gómez, M ;
Sanchez, JL ;
Morrison, G ;
Rauch, S ;
McLeod, C ;
Ma, R ;
Caroli, S ;
Alimonti, A ;
Petrucci, F ;
Bocca, B ;
Schramel, P ;
Zischka, M ;
Petterson, C ;
Wass, U .
SCIENCE OF THE TOTAL ENVIRONMENT, 2002, 299 (1-3) :1-19
[8]  
Gonzalez Garcia M. M., 2003, Analytical and Bioanalytical Chemistry, V375, P1229
[9]   ION-EXCHANGE RESINS CONTAINING S-BONDED DITHIZONE AND DEHYDRODITHIZONE AS FUNCTIONAL-GROUPS .1. PREPARATION OF THE RESINS AND INVESTIGATION OF THE SORPTION OF NOBLE-METALS AND BASE METALS [J].
GROTE, M ;
KETTRUP, A .
ANALYTICA CHIMICA ACTA, 1985, 172 (JUN) :223-239
[10]   FORMAZANS AS FUNCTIONAL-GROUPS OF CHELATING ION-EXCHANGERS .3. PROPERTIES AND ANALYTICAL APPLICATION OF FORMAZAN-LOADED ANION-EXCHANGERS [J].
GROTE, M ;
WIGGE, P ;
KETTRUP, A .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 310 (05) :369-377