In Vivo High-Frequency, Contrast-Enhanced Ultrasonography of Uveal Melanoma in Mice: Imaging Features and Histopathologic Correlations

被引:24
作者
Zhang, Qing [4 ]
Yang, Hua
Kang, Shin J.
Wang, Yanggan [2 ,7 ]
Wang, Geoffrey D. [5 ]
Coulthard, Tonya [6 ]
Grossniklaus, Hans E. [1 ,3 ]
机构
[1] Emory Univ, Sch Med, Dept Ophthalmol, LF Montgomery Ophthalm Pathol Lab,Emory Eye Ctr B, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Pediat, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Pathol, Atlanta, GA 30322 USA
[4] Cent S Univ Second Xiangya Hosp, Dept Ophthalmol, Changsha, Hunan, Peoples R China
[5] Univ Georgia, Dept Pharmaceut & Biomed Sci, Athens, GA 30602 USA
[6] VisualSonics, Toronto, ON, Canada
[7] Emory Univ, Sch Med, Childrens Healthcare Atlanta, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
FOCAL LIVER-LESIONS; CHOROIDAL MELANOMA; 3-DIMENSIONAL ULTRASOUND; CLINICAL-APPLICATIONS; PROGNOSTIC FACTORS; VOLUME; AGENTS; EFFICACY; THERAPY; SAFETY;
D O I
10.1167/iovs.10-6794
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the usefulness of in vivo imaging of uveal melanoma in mice using high-frequency contrast-enhanced ultrasound (HF-CE-US) with 2D or 3D modes and to correlate the sonographic findings with histopathologic characteristics. METHODS. Fourteen 12-week-old C57BL6 mice were inoculated into their right eyes with aliquots of 5 x 10(5)/2.5 mu L B16LS9 melanoma cells and were randomly assigned to either of two groups. At 7 days after inoculation, tumor-bearing eyes in group 1 (n = 8) were imaged using HF-CE-US to determine the 2D tumor size and relative blood volume; eyes in group 2 (n = 6) were imaged by 3D microbubble contrast-enhanced ultrasound, and the tumor volume was determined. Histologic tumor burden was quantified in enucleated eyes by image processing software, and microvascular density was determined by counting von Willebrand factor-positive vascular channels. Ultrasound images were evaluated and compared with histopathologic findings. RESULTS. Using HF-CE-US, melanomas were visualized as relatively hyperechoic regions. The intraobserver variability of sonographic measurements was 9.65% +/- 7.89%, and the coefficient of variation for multiple measurements was 7.33% +/- 5.71%. The correlation coefficient of sonographic volume or size and histologic area was 0.71 (P = 0.11) and 0.79 (P = 0.32). The relative blood volume within the tumor demonstrated sonographically correlated significantly with histologic tumor vascularity (r = 0.83; P < 0.001). CONCLUSIONS. There was a positive linear correlation between sonographic tumor measurements and histologic tumor burden in the mouse ocular melanoma model. Contrast-enhanced intensity corresponded with microvascular density and blood volume. HF-CE-US is a real-time, noninvasive, reliable method for in vivo evaluation of experimental intraocular melanoma tumor area and relative blood volume. (Invest Ophthalmol Vis Sci. 2011;52:2662-2668) DOI:10.1167/iovs.10-6794
引用
收藏
页码:2662 / 2668
页数:7
相关论文
共 40 条
  • [1] Boldt HC, 2008, OPHTHALMOLOGY, V115, P1390, DOI [10.1016/j.ophtha.2007, 10.1016/j.ophtha.2007.12.015]
  • [2] Three-dimensional ultrasound assessment of fetal liver volume in normal pregnancy: A comparison of reproducibility with two-dimensional ultrasound and a search for a volume constant
    Chang, FM
    Hsu, KF
    Ko, HC
    Yao, BL
    Chang, CH
    Yu, CH
    Chen, HY
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) : 381 - 389
  • [3] CORRELATIONS OF ACOUSTIC TISSUE TYPING OF MALIGNANT-MELANOMA AND HISTOPATHOLOGIC FEATURES AS A PREDICTOR OF DEATH
    COLEMAN, DJ
    SILVERMAN, RH
    RONDEAU, MJ
    LIZZI, FL
    MCLEAN, JW
    JAKOBIEC, FA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (04) : 380 - 388
  • [4] Three-dimensional ultrasound imaging -: Clinical applications
    Cusumano, A
    Coleman, DJ
    Silverman, RH
    Reinstein, DZ
    Rondeau, MJ
    Ursea, R
    Daly, SM
    Lloyd, HO
    [J]. OPHTHALMOLOGY, 1998, 105 (02) : 300 - 306
  • [5] EPIDEMIOLOGIC ASPECTS OF UVEAL MELANOMA
    EGAN, KM
    SEDDON, JM
    GLYNN, RJ
    GRAGOUDAS, ES
    ALBERT, DM
    [J]. SURVEY OF OPHTHALMOLOGY, 1988, 32 (04) : 239 - 251
  • [6] Ultrasound microbubble contrast agents: Fundamentals and application to gene and drug delivery
    Ferrara, Katherine
    Pollard, Rachel
    Borden, Mark
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2007, 9 : 415 - 447
  • [7] Radiation therapy for choroidal melanoma
    Finger, PT
    [J]. SURVEY OF OPHTHALMOLOGY, 1997, 42 (03) : 215 - 232
  • [8] A new ultrasound instrument for in vivo microimaging of mice
    Foster, FS
    Zhang, MY
    Zhou, YQ
    Liu, G
    Mehi, J
    Cherin, E
    Harasiewicz, KA
    Starkoski, BG
    Zan, L
    Knapik, DA
    Adamson, SL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (09) : 1165 - 1172
  • [9] GASS JDM, 1985, ARCH OPHTHALMOL-CHIC, V103, P924
  • [10] IN-VITRO EVALUATION OF 3-DIMENSIONAL ULTRASONOGRAPHY IN VOLUME ESTIMATION OF ABDOMINAL ORGANS
    GILJA, OH
    THUNE, N
    MATRE, K
    HAUSKEN, T
    ODEGAARD, S
    BERSTAD, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (02) : 157 - 165