A novel chip device based on wired capillary packed with high performance polymer-based monolith for HPLC: Reproducibility in preparation processes to obtain long columns

被引:16
作者
Hosoya, Ken [1 ]
Sakamoto, Mari [1 ]
Akai, Kunihiko [2 ]
Mori, Tomoko [1 ]
Kubo, Takuya [1 ]
Kaya, Kunimitsu [1 ]
Okada, Kazuma [3 ]
Tsujioka, Norio [3 ]
Tanaka, Nobuo [3 ]
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Sendai, Miyagi 9808579, Japan
[2] Hitachi Chem Co, Chikusei, Ibaraki 3088521, Japan
[3] Kyoto Inst Technol, Grad Sch Sci & Technol, Sakyo Ku, Kyoto 6068585, Japan
关键词
D O I
10.2116/analsci.24.149
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes the development of novel wired chip devices for mu-HPLC analyses. The monolithic capillary column to be wired was prepared using a tri-functional epoxy monomer, tris(2,3-epoxypropyl)isocyanurate with a diamine, 4-[(4-aminocyclohexyl)methyl]cyclohexylamine. The prepared column was evaluated by SEM observation of the sectional structure of column and mu-HPLC. In addition, the reproducibility in the preparation of long capillary columns having nearly I in length was extensively examined for applications of novel wired chip devices. The authors demonstrated that the monolithic structure of the prepared long capillary could be finely controlled under the strictly maintained operational conditions and thus the relative standard deviation (RSD) of the column properties such as the number of theoretical plates, retention factor, and permeability could be well controlled to become less than 10%. Furthermore, the wired chip device column showed that its high performance was kept even after chip preparation.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 16 条
  • [1] Preparation of glycerol dimethacrylate-based polymer monolith with unusual porous properties achieved via viscoelastic phase separation induced by monodisperse ultra high molecular weight poly(styrene) as a porogen
    Aoki, Hiroshi
    Kubo, Takuya
    Ikegami, Tohru
    Tanaka, Nobuo
    Hosoya, Ken
    Tokuda, Daisuke
    Ishizuka, Norio
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1119 (1-2) : 66 - 79
  • [2] Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography
    Claessens, HA
    van Straten, MA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) : 23 - 41
  • [3] Fabrication of high-permeability and high-capacity monolith for protein chromatography
    Du, Kai-Feng
    Yang, Dong
    Sun, Yan
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1163 (1-2) : 212 - 218
  • [4] FRECHET JMJ, 1965, Patent No. 5344310
  • [5] Analytical methods in environmental effects-directed investigations of effluents
    Hewitt, LM
    Marvin, CH
    [J]. MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH, 2005, 589 (03) : 208 - 232
  • [6] High-performance polymer-based monolithic capillary column
    Hosoya, Ken
    Hira, Natsuki
    Yamamoto, Katsuya
    Nishimura, Masaru
    Tanaka, Nobuo
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (16) : 5729 - 5735
  • [7] Monolithic bioreactor immobilizing trypsin for high-throughput analysis
    Kato, M
    Inuzuka, K
    Sakai-Kato, K
    Toyo'oka, T
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (06) : 1813 - 1818
  • [8] Properties of monolithic silica columns for HPLC
    Kobayashi, H
    Ikegami, T
    Kimura, H
    Hara, T
    Tokuda, D
    Tanaka, N
    [J]. ANALYTICAL SCIENCES, 2006, 22 (04) : 491 - 501
  • [9] A graphitized-carbon monolithic column
    Liang, CD
    Dai, S
    Guiochon, G
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (18) : 4904 - 4912
  • [10] Comparison of conventional microparticulate and a monolithic reversed-phase column for high-efficiency fast liquid chromatography of basic compounds
    McCalley, DV
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) : 51 - 64