Direct-coupled interstitial ultrasound applicators for simultaneous thermobrachytherapy: A feasibility study

被引:45
作者
Diederich, CJ
Khalil, IS
Stauffer, PR
Sneed, PK
Phillips, TL
机构
[1] University of California, S. Francisco-Radiat. Oncol. Dept., San Francisco
基金
美国国家卫生研究院;
关键词
hyperthermia; interstitial; ultrasound; multielement; simultaneous;
D O I
10.3109/02656739609022527
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study presents the design and performance evaluation of interstitial ultrasound applicators designed specifically for thermal therapy with simultaneous brachytherapy. The applicator consists of a multielement array of piezoceramic tubular radiators, each with separate power control, surrounded by thin layers of electrically-insulating and biocompatible coatings (less than or equal to 2.6 mm OD). A catheter which is compatible with remote afterloaders and standard brachytherapy technology forms the inner lumen. These 'direct-coupled interstitial ultrasound applicators' (DCIUA's) are placed within the tumour or target region, with the coated transducer surface forming the outer wall of the implant catheter. Thermocouple sensors embedded in the coating over each transducer can be used for continuous monitoring of the tissue/applicator interface temperatures for feedback control of power to each transducer segment. Theoretical acoustic power deposition and corresponding temperature distributions from thermal simulations have demonstrated that the radius of effective heating is highly dependent upon the acoustic efficiency of the piezoceramic transducers, with effective heating extending > 1-1.5 cm radially for typical DCIUA applicators that are 60-65% efficient. This exceeds the effective heating radius of both thermal conduction and RF heating technologies. Measurements with prototype multielement ultrasound applicators have demonstrated acoustic efficiencies between 60 and 65% and beam distributions which are fairly uniform and collimated to the transducer axial length. Thermal dosimetry measurements within in vivo tissues have demonstrated controllable therapeutic temperature rises at 1-1.5 cm radial depth from the applicators, which were in agreement with the simulations. This study demonstrates that direct-coupled ultrasound applicators, designed without an active cooling mechanism in order to accommodate the insertion of radiation sources, are practicable for simultaneous thermobrachytherapy and promises to give more adjustable heating patterns than current alternative techniques.
引用
收藏
页码:401 / 419
页数:19
相关论文
共 44 条
  • [1] RECENT DEVELOPMENTS IN MODELING HEAT-TRANSFER IN BLOOD-PERFUSED TISSUES
    ARKIN, H
    XU, LX
    HOLMES, KR
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (02) : 97 - 107
  • [2] THERMOTOLERANCE AND RADIATION SENSITIZING EFFECTS OF LONG-DURATION, MILD TEMPERATURE HYPERTHERMIA
    ARMOUR, E
    WANG, Z
    CORRY, P
    MARTINEZ, A
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1994, 10 (03) : 315 - 324
  • [3] EQUIVALENCE OF CONTINUOUS AND PULSE SIMULATED LOW-DOSE RATE IRRADIATION IN 9L GLIOSARCOMA CELLS AT 37-DEGREES-C AND 41-DEGREES-C
    ARMOUR, E
    WANG, ZH
    CORRY, P
    MARTINEZ, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01): : 109 - 114
  • [4] ARMOUR EP, 1993, CANCER RES, V53, P2740
  • [5] ARMOUR EP, 1991, CANCER RES, V51, P3088
  • [6] ARMOUR EP, 1993, INT J RADIAT ONCOL, V28, P171
  • [7] Chato J., 1990, Thermal Dosimetry and Treatment Planning (Clinical Thermology), P1
  • [8] CORRY PM, 1993, MED RADIOLOGY INTERS, P373
  • [9] DAHL O, 1990, INTRO PRACTICAL ASPE, P104
  • [10] DROOP - A RAPIDLY COMPUTABLE DESCRIPTOR OF LOCAL MINIMUM TISSUE TEMPERATURE DURING CONDUCTIVE INTERSTITIAL HYPERTHERMIA
    DEFORD, JA
    BABBS, CF
    PATEL, UH
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (03) : 333 - 342