A randomised comparison of two faecal immunochemical tests in population-based colorectal cancer screening

被引:33
作者
Grobbee, E. J. [1 ]
van der Vlugt, M. [2 ]
van Vuuren, A. J. [1 ]
Stroobants, A. K. [3 ]
Mundt, M. W. [4 ]
Spijker, W. J. [5 ]
Bongers, E. J. C. [6 ]
Kuipers, E. J.
Lansdorp-Vogelaar, I. [7 ]
Bossuyt, P. M. [8 ]
Dekker, E. [2 ]
Spaander, M. C. W. [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Gastroenterol & Hepatol, Room Hs-312,Gravendijkwal 230, NL-3015 CE Rotterdam, Netherlands
[2] Acad Med Ctr Amsterdam, Dept Gastroenterol & Hepatol, Amsterdam, Netherlands
[3] Acad Med Ctr Amsterdam, Dept Clin Chem, Amsterdam, Netherlands
[4] Flevoziekenhuis Almere, Dept Gastroenterol & Hepatol, Almere, Netherlands
[5] Reg Org Populat Screening South West Netherlands, Rotterdam, Netherlands
[6] Fdn Populat Screening Mid West, Amsterdam, Netherlands
[7] Erasmus Univ, Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
[8] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol Biostat & Bioinformat, Amsterdam, Netherlands
关键词
OCCULT BLOOD-TESTS; 3; ROUNDS; PERFORMANCE; HEMOGLOBIN; TRENDS; YIELD; RISK;
D O I
10.1136/gutjnl-2016-311819
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective Colorectal cancer screening programmes are implemented worldwide; many are based on faecal immunochemical testing (FIT). The aim of this study was to evaluate two frequently used FITs on participation, usability, positivity rate and diagnostic yield in population-based FIT screening. Design Comparison of two FITs was performed in a fourth round population-based FIT-screening cohort. Randomly selected individuals aged 50-74 were invited for FIT screening and were randomly allocated to receive an OC -Sensor (Eiken, Japan) or faecal occult blood (FOB)-Gold (Sentinel, Italy) test (March-December 2014). A cut-off of 10 mg haemoglobin (Hb)/g faeces (ie, 50 ng Hb/mL buffer for OC-Sensor and 59 ng Hb for FOB-Gold) was used for both FITs. Results In total, 19 291 eligible invitees were included (median age 61, IQR 57-67; 48% males): 9669 invitees received OC-Sensor and 9622 FOB-Gold; both tests were returned by 63% of invitees (p = 0.96). Tests were non-analysable in 0.7% of participants using OC-Sensor vs 2.0% using FOB-Gold (p < 0.001). Positivity rate was 7.9% for OC-Sensor, and 6.5% for FOB-Gold (p = 0.002). There was no significant difference in diagnostic yield of advanced neoplasia (1.4% for OC-Sensor vs 1.2% for FOB-Gold; p = 0.15) or positive predictive value (PPV; 31% vs 32%; p = 0.80). When comparing both tests at the same positivity rate instead of cut-off, they yielded similar PPV and detection rates. Conclusions The OC-Sensor and FOB-Gold were equally acceptable to a screening population. However, FOB-Gold was prone to more non-analysable tests. Comparison between FIT brands is usually done at the same Hb stool concentration. Our findings imply that for a fair comparison on diagnostic yield between FIT's positivity rate rather than Hb concentration should be used.
引用
收藏
页码:1975 / 1982
页数:8
相关论文
共 30 条
  • [1] Superior diagnostic performance of faecal immunochemical tests for haemoglobin in a head-to-head comparison with guaiac based faecal occult blood test among 2235 participants of screening colonoscopy
    Brenner, Hermann
    Tao, Sha
    [J]. EUROPEAN JOURNAL OF CANCER, 2013, 49 (14) : 3049 - 3054
  • [2] Carroll M., 2014, Evaluation of the quantitative faecal immunochemical tests for haemoglobin
  • [3] International Trends in Colorectal Cancer Incidence Rates
    Center, Melissa M.
    Jemal, Ahmedin
    Ward, Elizabeth
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2009, 18 (06) : 1688 - 1694
  • [4] Difference in Performance of Fecal Immunochemical Tests With the Same Hemoglobin Cutoff Concentration in a Nationwide Colorectal Cancer Screening Program
    Chiang, Tsung-Hsien
    Chuang, Shu-Lin
    Chen, Sam Li-Sheng
    Chiu, Han-Mo
    Yen, Amy Ming-Fang
    Chiu, Sherry Yueh-Hsia
    Fann, Jean Ching-Yuan
    Chou, Chu-Kuang
    Lee, Yi-Chia
    Wu, Ming-Shiang
    Chen, Hsiu-Hsi
    [J]. GASTROENTEROLOGY, 2014, 147 (06) : 1317 - 1326
  • [5] Lower Risk of Advanced Neoplasia Among Patients With a Previous Negative Result From a Fecal Test for Colorectal Cancer
    Denters, Maaike J.
    Deutekom, Marije
    Bossuyt, Patrick M.
    Stroobants, An K.
    Fockens, Paul
    Dekker, Evelien
    [J]. GASTROENTEROLOGY, 2012, 142 (03) : 497 - 504
  • [6] Implementation of population screening for colorectal cancer by repeated fecal occult blood test in the Netherlands
    Denters, Maaike J.
    Deutekom, Marije
    Fockens, Paul
    Bossuyt, Patrick M. M.
    Dekker, Evelien
    [J]. BMC GASTROENTEROLOGY, 2009, 9
  • [7] The American Joint Committee on Cancer: the 7th Edition of the AJCC Cancer Staging Manual and the Future of TNM
    Edge, Stephen B.
    Compton, Carolyn C.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2010, 17 (06) : 1471 - 1474
  • [8] Annual Report to the Nation on the Status of Cancer, 1975-2006, Featuring Colorectal Cancer Trends and Impact of Interventions (Risk Factors, Screening, and Treatment) to Reduce Future Rates
    Edwards, Brenda K.
    Ward, Elizabeth
    Kohler, Betsy A.
    Eheman, Christie
    Zauber, Ann G.
    Anderson, Robert N.
    Jemal, Ahmedin
    Schymura, Maria J.
    Lansdorp-Vogelaar, Iris
    Seeff, Laura C.
    van Ballegooijen, Marjolein
    Goede, S. Luuk
    Ries, Lynn A. G.
    [J]. CANCER, 2010, 116 (03) : 544 - 573
  • [9] Comparison between a guaiac and three immunochemical faecal occult blood tests in screening for colorectal cancer
    Faivre, J.
    Dancourt, V.
    Denis, B.
    Dorval, E.
    Piette, C.
    Perrin, Ph
    Bidan, J. M.
    Jard, C.
    Jung, S.
    Levillain, R.
    Viguier, J.
    Bretagne, J. F.
    [J]. EUROPEAN JOURNAL OF CANCER, 2012, 48 (16) : 2969 - 2976
  • [10] FOB-Gold, HB FEC IMM TEST SENT