Comparison of Unit Resolution Versus High-Resolution Accurate Mass for Parallel Reaction Monitoring

被引:19
|
作者
Heil, Lilian R. [1 ]
Remes, Philip M. [2 ]
MacCoss, Michael J. [1 ]
机构
[1] Univ Washington, Dept Genome Sci, Seattle, WA 98195 USA
[2] Thermo Fisher Sci, San Jose, CA 95134 USA
基金
美国国家卫生研究院;
关键词
parallel reaction monitoring; targeted proteomics; plasma; PROTEINS;
D O I
10.1021/acs.jproteome.1c00377
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Parallel reaction monitoring (PRM) is an increasingly popular alternative to selected reaction monitoring (SRM) for targeted proteomics. PRMs strengths over SRM are that it monitors all product ions in a single spectrum, thus eliminating the need to select interference-free product ions prior to data acquisition, and that it is most frequently performed on high-resolution instruments, such as quadrupole-orbitrap and quadrupole-time-of-flight instruments. Here, we show that the primary advantage of PRM is the ability to monitor all transitions in parallel and that high-resolution data are not necessary to obtain high-quality quantitative data. We run the same scheduled PRM assay, measuring 432 peptides from 126 plasma proteins, multiple times on an Orbitrap Eclipse Tribrid mass spectrometer, alternating separate liquid chromatography-tandem mass spectrometry runs between the high-resolution Orbitrap and the unit resolution linear ion trap for PRM. We find that both mass analyzers have similar technical precision and that the linear ion trap's superior sensitivity gives it better lower limits of quantitation for over 62% of peptides in the assay.
引用
收藏
页码:4435 / 4442
页数:8
相关论文
共 50 条
  • [21] Is it Time to Embrace High-Resolution, Accurate-Mass Mass Spectrometry for Pesticide Analysis?
    Fussell, Richard
    AMERICAN LABORATORY, 2016, 48 (01) : 37 - 39
  • [22] Illuminating the exposome with high-resolution accurate-mass mass spectrometry and nontargeted analysis
    Getzinger, Gordon J.
    Ferguson, P. Lee
    CURRENT OPINION IN ENVIRONMENTAL SCIENCE & HEALTH, 2020, 15 : 49 - 56
  • [23] CERVICAL RADICULOPATHY - COMPARISON OF HIGH-RESOLUTION CT VERSUS MYELOGRAPHY
    KASEFF, LG
    EATON, J
    BAIZ, T
    PITLYK, P
    IZZO, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1986, 7 (03) : 559 - 559
  • [24] Accurate and High-Resolution Particle Mass Measurement Using a Peak Filtering Algorithm
    Xiong, Caiqiao
    Pan, Yixin
    Fan, Jinghan
    Li, Yuze
    Wang, Jiyun
    Nie, Zongxiu
    ANALYTICAL CHEMISTRY, 2024, 96 (17) : 6511 - 6516
  • [25] In-Depth Glycoproteomic Characterization of γ-Conglutin by High-Resolution Accurate Mass Spectrometry
    Schiarea, Silvia
    Arnoldi, Lolita
    Fanelli, Roberto
    De Combarieu, Eric
    Chiabrando, Chiara
    PLOS ONE, 2013, 8 (09):
  • [26] pParse: A method for accurate determination of monoisotopic peaks in high-resolution mass spectra
    Yuan, Zuo-Fei
    Liu, Chao
    Wang, Hai-Peng
    Sun, Rui-Xiang
    Fu, Yan
    Zhang, Jing-Fen
    Wang, Le-Heng
    Chi, Hao
    Li, You
    Xiu, Li-Yun
    Wang, Wen-Ping
    He, Si-Min
    PROTEOMICS, 2012, 12 (02) : 226 - 235
  • [27] THE APPLICATION OF HIGH-RESOLUTION MASS-SPECTROMETRY TO SELECTED ION MONITORING
    HAZELBY, D
    TAYLOR, KT
    ANNALI DI CHIMICA, 1980, 70 (5-6) : 201 - 216
  • [28] Conventional high-resolution CT versus helical high-resolution MDCT in the detection of bronchiectasis
    Dodd, Jonathan D.
    Souza, Carolina A.
    Mueller, Nestor L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (02) : 414 - 420
  • [29] Untargeted Profiling of Shenfu Qiangxin Pills Based on High-Resolution Mass Spectrometry and Absolute Quantitation of Multiple Components Using Parallel Reaction Monitoring
    Gao, Yan
    Liang, Xv
    Zhang, Nihui
    Zhang, Xiangyang
    Li, Xia
    Gao, Wenyuan
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (23)
  • [30] Process Monitoring with High-Resolution CZT
    Wahl, Christopher G.
    Kaye, Willy
    Zhang, Feng
    Boucher, Y. Andy
    Jaworski, Jason
    Moran, Kevin
    Matthews, Thurston
    Tefft, David
    Yang, Hao
    Wang, Weiyi
    Kitchen, Brian
    Ulrich, Molly
    Slatina, Timothy
    Brown, Steven
    He, Zhong
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,