Effects of prosthesis alignment on pressure distribution at the stump/socket interface in transtibial amputees during unsupported stance and gait

被引:35
|
作者
Seelen, HAM
Anemaat, S
Janssen, HMH
Deckers, JHM
机构
[1] Inst Rehabil Res, NL-6432 CC Hoensbroek, Netherlands
[2] Rehabil Fdn Limburg, Hoensbroek, Netherlands
[3] Maastricht Univ, Dept Movement Sci, Maastricht, Netherlands
关键词
D O I
10.1191/0269215503cr678oa
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the effects of antero-posterior realignment of the prosthesis on pressure distribution at the stump/socket interface in unilateral transtibial amputees during unsupported stance and gait. Design: Cross-sectional group study. Setting: Outpatient rehabilitation clinic. Subjects: Seventeen unilateral transtibial amputees. Intervention: Antero-posterior prosthesis realignment using 0.5 cm heel or forefoot wedging. Measures: Pressure distribution changes at several sites at the stump/socket interface, expressed as peak pressure, peak pressure time, sustained submaximal load (MP80+) and time period of MP80+ (TP80+). Results: During stance, heel wedging led to a 30.4% decrease in mean pressure near the patella tendon and a 40.0% increase near the distal tibia site, whereas forefoot wedging led to a 30.0% decrease in pressure in the tibial end region. Antero-posterior ankle realignment did not lead to significant changes near the fibular head. During gait only heel wedging led to a 11.5% increase in peak pressure in the tibia end region. Mean peak pressure time increased 22.7% using heel wedging and decreased 8.8% using forefoot wedging. MP80+ increased 23.8% in the tibia end region during heel wedging and 17.0% in the subpatellar region during forefoot wedging. Conclusions: Antero-posterior realignment of the ankle joint led to an inverse loading and unloading of the subpatellar region versus tibial end region. However, results indicate that stump/socket interface pressure during stance seems not to be highly predictive as to pressure behaviour during gait. Ankle joint realignment led to significant differences in temporal sequences of tissue (un-)loading in the subpatellar area during gait.
引用
收藏
页码:787 / 796
页数:10
相关论文
共 38 条
  • [1] The Need for Stump-Socket Interface Pressure Measurment during Bidirectionally Perturbed Stance in Transtibial Amputees: a case study
    Shirazi, S. Y.
    Fatouraee, N.
    Safaeepour, Z.
    2014 21TH IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2014, : 220 - 223
  • [2] Pressure Distribution in Transtibial Prostheses Socket and the Stump Interface
    Rajtukova, V
    Hudak, R.
    Zivcak, J.
    Halfarova, P.
    Kudrikova, R.
    MODELLING OF MECHANICAL AND MECHATRONIC SYSTEMS, 2014, 96 : 374 - 381
  • [3] Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road
    Dou, Peng
    Jia, Xiaohong
    Suo, Shuangfu
    Wang, Rencheng
    Zhang, Ming
    CLINICAL BIOMECHANICS, 2006, 21 (10) : 1067 - 1073
  • [4] Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot
    Wolf, Sebastian I.
    Alimusaj, Merkur
    Fradet, Laetitia
    Siegel, Johannes
    Braatz, Frank
    CLINICAL BIOMECHANICS, 2009, 24 (10) : 860 - 865
  • [5] Effect of transtibial prosthesis alignment changes on out-of-plane socket reaction moments during walking in amputees
    Kobayashi, Toshiki
    Orendurff, Michael S.
    Zhang, Ming
    Boone, David A.
    JOURNAL OF BIOMECHANICS, 2012, 45 (15) : 2603 - 2609
  • [6] Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis
    Pirouzi, Gh.
    Abu Osman, N. A.
    Eshraghi, A.
    Ali, S.
    Gholizadeh, H.
    Abas, W. A. B. Wan
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [7] Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses
    Boone, David A.
    Kobayashi, Toshiki
    Chou, Teri G.
    Arabian, Adam K.
    Coleman, Kim L.
    Orendurff, Michael S.
    Zhang, Ming
    GAIT & POSTURE, 2013, 37 (04) : 620 - 626
  • [8] THE GAIT ANALYSIS AND INTERFACE PRESSURE MEASUREMENT BETWEEN STUMP AND RESIN-REINFORCED RAPID PROTOTYPING TRANSTIBIAL SOCKET
    Chen, Y. T.
    Peng, H. K.
    Lu, C. T.
    Hsu, L. H.
    Huang, G. F.
    Shih, H. S.
    IMECE2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 2, 2010, : 63 - 71
  • [9] Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket
    Convery, P
    Buis, AWP
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1999, 23 (02) : 107 - 112
  • [10] Effects of alignment on interface pressure for transtibial amputee during walking
    Jia, Xiaohong
    Suo, Shuangfu
    Meng, Fan
    Wang, Rencheng
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2008, 3 (06) : 339 - 343