HPLC method for levothyroxine quantification in long-acting drug delivery systems. Validation and evaluation of bovine serum albumin as levothyroxine stabilizer

被引:13
|
作者
Stewart, Sarah A. [1 ]
Waite, David [1 ]
Dominguez-Robles, Juan [1 ]
McAlister, Emma [1 ]
Permana, Andi Dian [2 ]
Donnelly, Ryan F. [1 ]
Larraneta, Eneko [1 ]
机构
[1] Queens Univ Belfast, Sch Pharm, Lisburn Rd 97, Belfast BT9 7BL, Antrim, North Ireland
[2] Univ Hasanuddin, Fac Pharm, Dept Pharmaceut, Makassar 90245, Indonesia
关键词
Levothyroxine; Implantable devices; drug stability; Hypothyroidism; Long acting drug delivery systems; high-performance liquid chromatography;
D O I
10.1016/j.jpba.2021.114182
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Deficiency of thyroid hormones (hypothyroidism) is treated with oral levothyroxine (LEVO). However, the effectiveness of oral administration is highly dependent on the co-administration of food and other drugs. This factor, in combination with the chronic nature of this condition, mean that there are concerns with patient compliance. Development of long acting formulations to treat hypothyroidism could potentially solve this problem. However, LEVO instability in solution could be problematic. In order to develop long acting LEVO delivery systems in vitro drug release experiments should be carried out. However, short term LEVO stability in aqueous solution will prevent this. BSA was used as a stabiliser for LEVO; extending the stability of the drug in aqueous solutions from a few hours to 2 weeks. In order to achieve this, the required concentration of the protein was 0.1% w/v. Subsequently, an HPLC method capable of separating LEVO from the protein was developed and validated following ICH guidelines. The analysis was carried out using a reverse phase HPLC method on an Agilent 1220 Infinity II LC system. The column used to achieve separation was a Zorbax Eclipse plus C18 (95 angstrom pore size, 250 mm length x 4.6 mm internal diameter; 5 mu m particle size). The mobile phase used was composed of acetonitrile and 0.1% trifluoroacetic acid at a ratio of 50:50% v/v. UV detection of LEVO sodium was carried out at 225 nm. The retention time for the drug was 6.6 minutes. The method showed a limit of detection of 0.03 mu g/mL and a limit of quantification of 0.09 mu g/mL. Finally, this method was used to evaluate the release from implants containing 20% w/w of LEVO. These devices were prepared using a solvent casting method with poly(caprolactone) and LEVO. These devices showed an initial burst release over the first 3 days. Subsequently, they were capable of providing a linear release rate over the following 25 days. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 2 条
  • [1] Development and validation of a high-performance liquid chromatography method for levothyroxine sodium quantification in plasma for pre-clinical evaluation of long-acting drug delivery systems
    Permana, Andi Dian
    Stewart, Sarah A.
    Dominguez-Robles, Juan
    Amir, Muh. Nur
    Bahar, Muh. Akbar
    Donnelly, Ryan F.
    Larraneta, Eneko
    ANALYTICAL METHODS, 2021, 13 (43) : 5204 - 5210
  • [2] Establishment of Optimal Drug Delivery System and Evaluation of Utilization of Hydrogel Contact Lens According to the Addition Method of Tretinoin and Bovine Serum Albumin
    Park, Hye-In
    Sung, A-Young
    POLYMERS, 2025, 17 (02)