On-Line Real-Time Monitoring of a Rapid Enzymatic Oil Degumming Process: A Feasibility Study Using Free-Run Near-Infrared Spectroscopy

被引:3
|
作者
Forsberg, Jakob [1 ]
Nielsen, Per Munk [2 ]
Engelsen, Soren Balling [1 ]
Sorensen, Klavs Martin [1 ]
机构
[1] Univ Copenhagen, Dept Food Sci, Food Analyt & Biotechnol, Rolighedsvej 26, DK-1958 Frederiksberg C, Denmark
[2] Novozymes, Oils & Fats Applicat Res, Biologiens Vej 2, DK-2800 Lyngby, Denmark
关键词
Near-infrared spectroscopy; process analytical technology (PAT); process control; processing technology; chemometrics; vegetable oil; oil refinement; variable selection; RAMAN-SPECTROSCOPY; TRANSESTERIFICATION; NIR;
D O I
10.3390/foods10102368
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Enzymatic degumming is a well established process in vegetable oil refinement, resulting in higher oil yield and a more stable downstream processing compared to traditional degumming methods using acid and water. During the reaction, phospholipids in the oil are hydrolyzed to free fatty acids and lyso-phospholipids. The process is typically monitored by off-line laboratory measurements of the free fatty acid content in the oil, and there is a demand for an automated on-line monitoring strategy to increase both yield and understanding of the process dynamics. This paper investigates the option of using Near-Infrared spectroscopy (NIRS) to monitor the enzymatic degumming reaction. A new method for balancing spectral noise and keeping the chemical information in the spectra obtained from a rapid changing chemical process is suggested. The effect of a varying measurement averaging window width (0 to 300 s), preprocessing method and variable selection algorithm is evaluated, aiming to obtain the most accurate and robust calibration model for prediction of the free fatty acid content (% (w/w)). The optimal Partial Least Squares (PLS) model includes eight wavelength variables, as found by rPLS (recursive PLS) calibration, and yields an RMSECV (Root Mean Square Error of Cross Validation) of 0.05% (w/w) free fatty acid using five latent variables.</p>
引用
收藏
页数:15
相关论文
共 50 条
  • [31] NIR spectroscopy as a process analytical technology (PAT) tool for on-line and real-time monitoring of an extraction process
    Wu, Yongjiang
    Jin, Ye
    Li, Yerui
    Sun, Di
    Liu, Xuesong
    Chen, Yong
    VIBRATIONAL SPECTROSCOPY, 2012, 58 : 109 - 118
  • [32] Real-time process monitoring in a semi-continuous fluid-bed dryer - microwave resonance technology versus near-infrared spectroscopy
    Peters, Johanna
    Teske, Andreas
    Taute, Wolfgang
    Doescher, Claas
    Hoeft, Michael
    Knoechel, Reinhard
    Breitkreutz, Joerg
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 537 (1-2) : 193 - 201
  • [33] In-line and Real-time Monitoring of Resonant Acoustic Mixing by Near-infrared Spectroscopy Combined with Chemometric Technology for Process Analytical Technology Applications in Pharmaceutical Powder Blending Systems
    Tanaka, Ryoma
    Takahashi, Naoyuki
    Nakamura, Yasuaki
    Hattori, Yusuke
    Ashizawa, Kazuhide
    Otsuka, Makoto
    ANALYTICAL SCIENCES, 2017, 33 (01) : 41 - 46
  • [34] In-line and Real-time Monitoring of Resonant Acoustic Mixing by Near-infrared Spectroscopy Combined with Chemometric Technology for Process Analytical Technology Applications in Pharmaceutical Powder Blending Systems
    Ryoma Tanaka
    Naoyuki Takahashi
    Yasuaki Nakamura
    Yusuke Hattori
    Kazuhide Ashizawa
    Makoto Otsuka
    Analytical Sciences, 2017, 33 : 41 - 46
  • [35] Quantitative monitoring of an activated sludge reactor using on-line UV-visible and near-infrared spectroscopy
    Mafalda C. Sarraguça
    Ana Paulo
    Madalena M. Alves
    Ana M. A. Dias
    João A. Lopes
    Eugénio C. Ferreira
    Analytical and Bioanalytical Chemistry, 2009, 395 : 1159 - 1166
  • [36] Quantitative monitoring of an activated sludge reactor using on-line UV-visible and near-infrared spectroscopy
    Sarraguca, Mafalda C.
    Paulo, Ana
    Alves, Madalena M.
    Dias, Ana M. A.
    Lopes, Joao A.
    Ferreira, Eugenio C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (04) : 1159 - 1166
  • [37] Development of a Rapid Process Monitoring Method for Dry-Coated Tableting Process by Using Near-Infrared Spectroscopy
    Ito, Masatomo
    Suzuki, Tatsuya
    Wakiyama, Naoki
    Teramoto, Hiroshi
    Yonemochi, Etsuo
    Terada, Katsuhide
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2011, 59 (07) : 868 - 873
  • [38] Real-time determination of critical quality attributes using near-infrared spectroscopy: A contribution for Process Analytical Technology (PAT)
    Rosas, Juan G.
    Blanco, Marcel
    Gonzalez, Josep M.
    Alcala, Mane
    TALANTA, 2012, 97 : 163 - 170
  • [39] Application of Near-Infrared Spectroscopy in Real-Time Monitoring of Product Attributes of Ribbed Roller Compacted Flakes
    Asim Kumar Samanta
    Atul D. Karande
    Ka Yun Ng
    Paul Wan Sia Heng
    AAPS PharmSciTech, 2013, 14 : 86 - 100
  • [40] Application of Near-Infrared Spectroscopy in Real-Time Monitoring of Product Attributes of Ribbed Roller Compacted Flakes
    Samanta, Asim Kumar
    Karande, Atul D.
    Ng, Ka Yun
    Heng, Paul Wan Sia
    AAPS PHARMSCITECH, 2013, 14 (01): : 86 - 100