Cone beam computed tomography and image registration based on target area for stereotactic body radiation therapy of lung cancer

被引:1
|
作者
Gui, Long-Gang [1 ]
Shi, Miao [1 ]
Li, Jun [1 ]
机构
[1] Northern Jiangsu Peoples Hosp, Radiotherapy Ctr, Yangzhou 225001, Jiangsu, Peoples R China
关键词
Lung cancer; SBRT; CBCT; image registration; dosimetric parameter; INTENSITY-MODULATED RADIOTHERAPY; CLINICAL-OUTCOMES; DIAGNOSTIC-VALUE; CT; IRRADIATION;
D O I
10.1080/16878507.2021.1981754
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper aims to compare the dosimetric parameters of the original plan and the simulated plan to explore the clinical value of cone beam CT and planned CT image registration based on the target area. The results showed that Dmax, Dmin, dmean and V60 of PTV in the original plan were (108.3 +/- 1.1)%, (97.2 +/- 0.3)%, (102.6 +/- 0.6)% and (95.2 +/- 0.6)% respectively. The Dmax of spinal cord was (9.6 +/- 1.8) gy, the V20 of lung was (5.2 +/- 1.9)%, and the dmean of lung was (- 3.7 +/- 1.5) gy; however, when the target area was translated in the three directions of the patient's back, right side and foot, the dosimetric parameters of the target area (Dmax, Dmin and V60), dmean and V20 of lung and Dmax of spinal cord showed slight differences, which all met the limit requirements of target area and dangerous organs (OARs) (RTOG) 0915 report. Therefore, target based image registration is feasible. If the registration translation error is less than or equal to 1 cm, there is no need to re move the treatment bed according to the registration error.
引用
收藏
页码:404 / 411
页数:8
相关论文
共 50 条
  • [21] Advances in Stereotactic Body Radiation Therapy for Lung Cancer
    Lee, Katie N.
    Owen, Dawn
    CANCER JOURNAL, 2024, 30 (06) : 401 - 406
  • [22] Dosimetric Uncertainties Resulting From Interfractional Anatomic Variations for Patients Receiving Pancreas Stereotactic Body Radiation Therapy and Cone Beam Computed Tomography Image Guidance
    Niedzielski, Joshua S.
    Liu, Yufei
    Ng, Sylvia S. W.
    Martin, Rachael M.
    Perles, Luis A.
    Beddar, Sam
    Rebueno, Neal
    Koay, Eugene J.
    Taniguchi, Cullen
    Holliday, Emma B.
    Das, Prajnan
    Smith, Grace L.
    Minsky, Bruce D.
    Ludmir, Ethan B.
    Herman, Joseph M.
    Koong, Albert
    Sawakuchi, Gabriel O.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (05): : 1298 - 1309
  • [23] Interinstitutional variations in planning for stereotactic body radiation therapy for lung cancer
    Matsuo, Yukinori
    Takayama, Kenji
    Nagata, Yasushi
    Kunieda, Etsuo
    Tateoka, Kunihiko
    Ishizuka, Naoki
    Mizowaki, Takashi
    Norihisa, Yoshiki
    Sakamoto, Masato
    Narita, Yuichiro
    Ishikura, Satoshi
    Hiraoka, Masahiro
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02): : 416 - 425
  • [24] Optimization of four-dimensional cone-beam computed tomography in image-guided radiation therapy of the lung
    Ahmad, Moiz
    Pan, Tinsu
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [25] Evaluation of Image Enhancement Method on Target Registration Using Cone Beam CT in Radiation Therapy
    Yan, Hui
    Lei, Ren
    Wu, Jackie
    Di, Fu
    Yin, Fang-Fang
    CLINICAL MEDICINE INSIGHTS-ONCOLOGY, 2008, 2 : 289 - 299
  • [26] Comparison between manual and automatic image registration in image-guided radiation therapy using megavoltage cone-beam computed tomography with an imaging beam line for prostate cancer
    Hashido T.
    Nakasone S.
    Fukao M.
    Ota S.
    Inoue S.
    Radiological Physics and Technology, 2018, 11 (4) : 392 - 405
  • [27] Inter-scan and inter-observer tumour volume delineation variability on cone beam computed tomography in patients treated with stereotactic body radiation therapy for early-stage non-small cell lung cancer
    Hou, Ying
    Lee, Stephanie
    Agrawal, Vishesh
    Romano, John
    Baldini, Elizabeth H.
    Chen, Aileen B.
    Kozono, David E.
    Killoran, Joseph H.
    Wagar, Matthew
    Hacker, Fred L.
    Aerts, Hugo J. W. L.
    Lewis, John H.
    Mak, Raymond H.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (01) : 93 - 98
  • [28] Intrafractional motion in stereotactic body radiotherapy of spinal metastases utilizing cone beam computed tomography image guidance
    Svestad, Jorund Graadal
    Ramberg, Christina
    Skar, Birgitte
    Hellebust, Taran Paulsen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 12 : 1 - 6
  • [29] Comparison of different registration methods in cone-beam computed tomography for breast boost radiation therapy
    Lastrucci, A.
    Fedeli, L.
    Marciello, L.
    Serventi, E.
    Segnini, S.
    Meucci, F.
    Bernardi, L.
    Ricci, R.
    Marzano, S.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [30] Absorbed dose measurements for kV-cone beam computed tomography in image-guided radiation therapy
    Hioki, Kazunari
    Araki, Fujio
    Ohno, Takeshi
    Nakaguchi, Yuji
    Tomiyama, Yuuki
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7297 - 7313