Shear wave elastography using amplitude-modulated acoustic radiation force and phase-sensitive optical coherence tomography

被引:50
作者
Nguyen, Thu-Mai [1 ]
Arnal, Bastien [1 ]
Song, Shaozhen [1 ,2 ,3 ]
Huang, Zhihong [2 ,3 ]
Wang, Ruikang K. [1 ,4 ]
O'Donnell, Matthew [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98105 USA
[2] Univ Dundee, Sch Engn, Dept Phys, Dundee DD1 4HN, Scotland
[3] Univ Dundee, Sch Engn, Dept Math, Dundee DD1 4HN, Scotland
[4] Univ Washington, Dept Ophthalmol, Seattle, WA 98104 USA
关键词
optical coherence elastography; optical coherence tomography; shear wave elastography; ultrasound radiation force; pulse compression; coded excitation; PROPAGATION;
D O I
10.1117/1.JBO.20.1.016001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Investigating the elasticity of ocular tissue (cornea and intraocular lens) could help the understanding and management of pathologies related to biomechanical deficiency. In previous studies, we introduced a setup based on optical coherence tomography for shear wave elastography (SWE) with high resolution and high sensitivity. SWE determines tissue stiffness from the propagation speed of shear waves launched within tissue. We proposed acoustic radiation force to remotely induce shear waves by focusing an ultrasound (US) beam in tissue, similar to several elastography techniques. Minimizing the maximum US pressure is essential in ophthalmology for safety reasons. For this purpose, we propose a pulse compression approach. It utilizes coded US emissions to generate shear waves where the energy is spread over a long emission, and then numerically compressed into a short, localized, and high-energy pulse. We used a 7.5-MHz single-element focused transducer driven by coded excitations where the amplitude is modulated by a linear frequency-swept square wave (1 to 7 kHz). An inverse filter approach was used for compression. We demonstrate the feasibility of performing shear wave elastography measurements in tissue-mimicking phantoms at low US pressures (mechanical index < 0.6). (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 28 条
  • [1] Cookt C. E., 1959, P IRE, V31, P310
  • [2] QUANTITATIVE ASSESSMENT OF ARTERIAL WALL BIOMECHANICAL PROPERTIES USING SHEAR WAVE IMAGING
    Couade, Mathieu
    Pernot, Mathieu
    Prada, Claire
    Messas, Emmanuel
    Emmerich, Joseph
    Bruneval, Patrick
    Criton, Aline
    Fink, Mathias
    Tanter, Mickael
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (10) : 1662 - 1676
  • [3] The Variance of Quantitative Estimates in Shear Wave Imaging: Theory and Experiments
    Deffieux, Thomas
    Gennisson, Jean-Luc
    Larrat, Benoit
    Fink, Mathias
    Tanter, Mickael
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (11) : 2390 - 2410
  • [4] Method for optical coherence elastography of the cornea
    Ford, Matthew R.
    Dupps, William J., Jr.
    Rollins, Andrew M.
    Roy, Abhijit Sinha
    Hu, Zhilin
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
  • [5] Phantom materials for elastography
    Hall, TJ
    Bilgen, M
    Insana, MF
    Krouskop, TA
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) : 1355 - 1365
  • [6] In vivo three-dimensional optical coherence elastography
    Kennedy, Brendan F.
    Liang, Xing
    Adie, Steven G.
    Gerstmann, Derek K.
    Quirk, Bryden C.
    Boppart, Stephen A.
    Sampson, David D.
    [J]. OPTICS EXPRESS, 2011, 19 (07): : 6623 - 6634
  • [7] In vivo dynamic optical coherence elastography using a ring actuator
    Kennedy, Brendan F.
    Hillman, Timothy R.
    McLaughlin, Robert A.
    Quirk, Bryden C.
    Sampson, David D.
    [J]. OPTICS EXPRESS, 2009, 17 (24): : 21762 - 21772
  • [8] PULSE COMPRESSION BY MEANS OF LINEAR-PERIOD MODULATION
    KROSZCZYNSKI, JJ
    [J]. PROCEEDINGS OF THE IEEE, 1969, 57 (07) : 1260 - +
  • [9] Dynamic optical coherence tomography measurements of elastic wave propagation in tissue-mimicking phantoms and mouse cornea in vivo
    Li, Jiasong
    Wang, Shang
    Manapuram, Ravi Kiran
    Singh, Manmohan
    Menodiado, Floredes M.
    Aglyamov, Salavat
    Emelianov, Stanislav
    Twa, Michael D.
    Larin, Kirill V.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (12)
  • [10] Dynamic spectral-domain optical coherence elastography for tissue characterization
    Liang, Xing
    Adie, Steven G.
    John, Renu
    Boppart, Stephen A.
    [J]. OPTICS EXPRESS, 2010, 18 (13): : 14183 - 14190