Comparison of Azure Kinect overground gait spatiotemporal parameters to marker based optical motion capture

被引:28
|
作者
Guess, Trent M. [1 ,2 ,4 ]
Bliss, Rebecca [1 ]
Hall, Jamie B. [1 ]
Kiselica, Andrew M. [3 ]
机构
[1] Univ Missouri, Dept Phys Therapy, Columbia, MO USA
[2] Univ Missouri, Dept Orthopaed Surg, Columbia, MO USA
[3] Univ Missouri, Dept Hlth Psychol, Columbia, MO USA
[4] Univ Missouri, Columbia, MO 65211 USA
关键词
Azure Kinect; Spatiotemporal; Dual task; Motion capture; Walking; DUAL-TASK PERFORMANCE; PARKINSONS-DISEASE; FORMAL METHODS; SINGLE-TASK; IMPAIRMENT;
D O I
10.1016/j.gaitpost.2022.05.021
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Instrumented measurement of spatiotemporal parameters during walking can provide valuable information on an individual's overall function and health. Efficient, inexpensive, and accurate measurement of overground walking spatiotemporal parameters would be a critical component of providing point-of-care assessments of gait function, concussion recovery, fall-risk, and cognitive decline. Depth cameras combined with skeleton pose tracking algorithms, such as the Microsoft Kinect with body tracking software, have been used to measure walking spatiotemporal parameters. However, the ability of the latest generation Microsoft Kinect sensor, the Azure Kinect, to accurately measure overground walking spatiotemporal parameters has not been evaluated in the literature.Research question: The purpose of this work was to compare overground walking spatiotemporal parameters measurements from a 12 camera Vicon optical motion capture system to measurements of a single Azure Kinect with body tracking SDK (software development kit). Methods: Spatiotemporal parameters of overground walking were simultaneously collected on twenty young healthy participants. Stride length, stride time, step length and step width were derived from ankle joint center locations and measurements from the two instruments were compared using descriptive statistics, scatter plots, Pearson correlation analyses, and Bland-Altman analyses.Results: Pearson correlation coefficients were greater than 0.87 for all spatiotemporal parameters with most parameters demonstrating very strong (> 0.9) agreement. The mean of the differences for stride length between measurements was 35.6 mm for the left limb and 39.1 mm for the right limb, both of which are less than 3% of average stride length. Mean of the differences for step width and stride time were less than 2% and 1% of their averages respectively.Significance: A single Microsoft Azure Kinect with body tracking SDK can provide clinically relevant measurement of walking spatiotemporal parameters, providing accessible and objective measurements that can improve clinical decision making across a variety of patient populations.
引用
收藏
页码:130 / 136
页数:7
相关论文
共 50 条
  • [31] Influence Of Sex On Marker To Marker-less Motion Capture Evaluations Of Gait Biomechanics
    Wills, Neil A.
    Pamukoff, Derek N.
    Eghobamien, Iwi J.
    Nwaokoro, Vital I.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 989 - 990
  • [32] Comparison of 3D Joint Angles Measured With the Kinect 2.0 Skeletal Tracker Versus a Marker-Based Motion Capture System
    Guess, Trent M.
    Razu, Swithin
    Jahandar, Amirhossein
    Skubic, Marjorie
    Huo, Zhiyu
    JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (02) : 176 - 181
  • [33] Spatial accuracy and reliability of the Microsoft Kinect V2 in the assessment of joint movement in comparison to marker-based motion capture (Vicon)
    Otte, K.
    Kayser, B.
    Mansow-Model, S.
    Brandt, A. U.
    Verrel, J.
    Schmitz-Huebsch, T.
    MOVEMENT DISORDERS, 2016, 31 : S188 - S189
  • [34] Comparison of marker-less and marker-based motion capture for baseball pitching kinematics
    Fleisig, Glenn S.
    Slowik, Jonathan S.
    Wassom, Derek
    Yanagita, Yuki
    Bishop, Jasper
    Diffendaffer, Alek
    SPORTS BIOMECHANICS, 2024, 23 (12) : 2950 - 2959
  • [35] Motion Capture and Reconstruction Based on Depth Information Using Kinect
    Zeng, Ming
    Liu, Zhengcun
    Meng, Qinghao
    Bai, Zhengbiao
    Jia, Haiyan
    2012 5TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), 2012, : 1381 - 1385
  • [36] Motion Capture of Maintenance Personnel Based on Multi-Kinect
    Han, Guozhu
    Song, Wu
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, RISK, MAINTENANCE, AND SAFETY ENGINEERING (QR2MSE), VOLS I-IV, 2013, : 1297 - 1299
  • [37] Feasibility of a low-cost system based on the Microsoft Kinect to investigate spatiotemporal gait parameters in people with Multiple Sclerosis
    Marti, Veronica G. Garcia
    Latorre, Jorge
    Ortu, Elena
    Llorens, Roberto
    Coghe, Giancarlo
    Pau, Massimiliano
    Cocco, Eleonora
    MULTIPLE SCLEROSIS JOURNAL, 2019, 25 (07) : 1054 - 1054
  • [38] Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters
    Dolatabadi, Elham
    Taati, Babak
    Mihailidis, Alex
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (09) : 952 - 958
  • [39] A new illuminated contour-based marker system for optical motion capture
    Barca, Jan Carlo
    Rumantir, Grace
    Li, Raymond Koon
    2006 INNOVATIONS IN INFORMATION TECHNOLOGY, 2006, : 532 - +
  • [40] Comparison of the Performance of the Leap Motion ControllerTM with a Standard Marker-Based Motion Capture System
    Ganguly, Amartya
    Rashidi, Gabriel
    Mombaur, Katja
    SENSORS, 2021, 21 (05) : 1 - 16