Characteristics of hydroxyapatite coated titanium porous coatings on Ti-6Al-4V substrates by plasma sprayed method

被引:21
作者
Yang, C. Y.
Chen, C. R.
Chang, E.
Lee, T. M. [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Orthoped, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Dept Mat Sci & Engn, Tainan 701, Taiwan
[3] Natl Chung Cheng Univ, Inst Oral Med, Tainan 701, Taiwan
关键词
hydroxyapatite; titanium; porous coating; plasma sprayed;
D O I
10.1002/jbm.b.30750
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A porous metal coating applied to solid substrate implants has been shown, in vivo, to anchor implants by bone ingrowth. Calcium phosphate ceramics, in particular hydroxyapatite [Ca-10(PO4)(6)(OH)(2), HA], are bioactive ceramics, which are known to be biocompatible and osteoconductive, and these ceramics deposited on to porous-coated devices may enhance bone ingrowth and implant fixation. In this study, bi-feedstock of the titanium powder and composite (Na2CO3/HA) powder were simultaneously deposited on a Ti-6AI-4V substrate by a plasma sprayed method. At high temperature of plasma torch, the solid state of Na2CO3 would decompose to release CO2 gas and then eject the molten Ti powder to induce the interconnected pores in the coatings. After cleaning and soaking in deionized water, the residual Na2CO3 in the coating would dissolve to form the open pores, and the HA would exist at the surface of pores in the inner coatings. By varying the particle size of the composite powder, the porosity of porous coating could be varied from 25.0 to 34.0%, and the average pore size of the porous coating could be varied to range between 158.5 and 202.0 mu m. Using a standard adhesive test (ASTM C-633), the bonding strength of the coating is between 27.3 and 38.2 MPa. By SEM, the HA was observed at the surface of inner pore in the porous coating. These results suggest that the method exhibits the potential to manufacture the bioactive ceramics on to porous-coated specimen to achieve bone ingrowth fixation for biomedical applications. (C) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:450 / 459
页数:10
相关论文
共 27 条
[1]   Effects of fluid flow on the in vitro degradation kinetics of biodegradable scaffolds for tissue engineering [J].
Agrawal, CM ;
McKinney, JS ;
Lanctot, D ;
Athanasiou, KA .
BIOMATERIALS, 2000, 21 (23) :2443-2452
[2]  
Andersen P., 1985, QUANTITATIVE CHARACT, P7
[3]  
Berger RA, 2001, CLIN ORTHOP RELAT R, P196
[4]  
BOBYN JD, 1980, CLIN ORTHOP RELAT R, P263
[5]   THE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS - 2-YEAR RESULTS OF A PROSPECTIVE CONSECUTIVE SERIES [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :337-346
[6]   ENHANCED INGROWTH OF POROUS-COATED COCR IMPLANTS PLASMA-SPRAYED WITH TRICALCIUM PHOSPHATE [J].
CHAE, JC ;
COLLIER, JP ;
MAYOR, MB ;
SURPRENANT, VA ;
DAUPHINAIS, LA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (01) :93-102
[7]   Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components [J].
Coathup, MJ ;
Blackburn, J ;
Goodship, AE ;
Cunningham, JL ;
Smith, T ;
Blunn, GW .
BIOMATERIALS, 2005, 26 (19) :4161-4169
[8]   A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem [J].
Coathup, MJ ;
Blunn, GW ;
Flynn, N ;
Williams, C ;
Thomas, NP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :118-123
[9]  
COLLIER JP, 1988, CLIN ORTHOP RELAT R, P173
[10]  
COOK SD, 1988, CLIN ORTHOP RELAT R, P90