Spectral propagation-based x-ray phase-contrast computed tomography

被引:1
作者
Schaff, Florian [1 ]
Pollock, James A. [1 ]
Morgan, Kaye S. [1 ]
Kitchen, Marcus J. [1 ,2 ]
机构
[1] Monash Univ, Sch Phys & Astron, Clayton, Vic, Australia
[2] Monash Univ, Ritchie Ctr, Clayton, Vic, Australia
基金
澳大利亚研究理事会;
关键词
x-ray phase contrast; computed tomography; spectral imaging; phase retrieval; electron density; effective atomic number; RETRIEVAL;
D O I
10.1117/1.JMI.9.3.031506
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Propagation-based x-ray imaging (PBI) is a phase-contrast technique that is employed in high-resolution imaging by introducing some distance between sample and detector. PBI causes characteristic intensity fringes that have to be processed with appropriate phase-retrieval algorithms, which has historically been a difficult task for objects composed of several different materials. Spectral x-ray imaging has been introduced to PBI to overcome this issue and to potentially utilize the spectral nature of the data for material-specific imaging. We aim to explore the potential of spectral PBI in three-dimensional computed tomography (CT) imaging in this work. Approach: We demonstrate phase-retrieval for experimental high-resolution spectral propagation-based CT data of a simple two-component sample, as well as a multimaterial capacitor test sample. Phase-retrieval was performed using an algorithm based on the Alvarez-Macovski model. Virtual monochromatic (VMI) and effective atomic number images were calculated after phase-retrieval. Results: Phase-retrieval results from the spectral data set show a distinct gray-level for each material with no residual phase-contrast fringes. Several representations of the phase-retrieved data are provided. The VMI is used to display an attenuation-equivalent image at a chosen display energy of 80 keV, to provide good separation of materials with minimal noise. The effective atomic number image shows the material composition of the sample. Conclusions: Spectral photon-counting detector technology has already been shown to be compatible with spectral PBI, and there is a foreseeable need for robust phase-retrieval in high-resolution, spectral x-ray CT in the future. Our results demonstrate the feasibility of phase-retrieval for spectral PBI CT. (C) 2022 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Revising the lower statistical limit of x-ray grating-based phase-contrast computed tomography
    Marschner, Mathias
    Birnbacher, Lorenz
    Willner, Marian
    Chabior, Michael
    Herzen, Julia
    Noel, Peter B.
    Pfeiffer, Franz
    PLOS ONE, 2017, 12 (09):
  • [42] Phase-contrast X-ray imaging based on interferometry
    Momose, A
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 136 - 142
  • [43] Wide-Cone Angle Phase-Contrast X-Ray Computed Tomography of Synthetic Polymer Materials
    Kalasova, Dominika
    Brinek, Adam
    Slouf, Miroslav
    Duskova-Smrckova, Miroslava
    Zikmund, Tomas
    Patakova, Zuzana
    Kaiser, Jozef
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (11) : 8910 - 8918
  • [44] Joint Reconstruction of Absorption and Refractive Properties in Propagation-Based X-ray Phase-Contrast Tomography via a Non-Linear Image Reconstruction Algorithm
    Chen, Yujia
    Wang, Kun
    Gursoy, Doga
    Soriano, Carmen
    De Carlo, Francesco
    Anastasio, Mark A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [45] Phase-contrast X-ray tomography using Teague's method
    Baillie, Thomas W.
    Gureyev, Timur E.
    Schmalz, Jelena A.
    Pavlov, Konstantin M.
    OPTICS EXPRESS, 2012, 20 (15): : 16913 - 16925
  • [46] Propagation-based x-ray phase contrast imaging using an iterative phase diversity technique
    Carroll, Aidan J.
    van Riessen, Grant A.
    Balaur, Eugeniu
    Dolbnya, Igor P.
    Tran, Giang N.
    Peele, Andrew G.
    JOURNAL OF OPTICS, 2018, 20 (03)
  • [47] Phase-contrast X-ray tomography: Contrast mechanism and roles of phase retrieval
    Wu, Xizeng
    Liu, Hong
    Yan, Amin
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : S8 - S12
  • [48] Investigation on the Dependency of Phase Retrieval Accuracy Versus Edge Enhancement to the Noise Ratio of X-ray Propagation-Based Phase-Contrast Imaging
    Zhang, Lin
    Zhao, Huijuan
    Jiang, Jingying
    Zhang, Limin
    Li, Jiao
    Gao, Feng
    Zhou, Zhongxing
    MICROSCOPY AND MICROANALYSIS, 2019, 25 (05) : 1201 - 1212
  • [49] Direct Conversion X-ray Detector with Micron-Scale Pixel Pitch for Edge-Illumination and Propagation-Based X-ray Phase-Contrast Imaging
    Pil-Ali, Abdollah
    Adnani, Sahar
    Scott, Christopher C.
    Karim, Karim S.
    SENSORS, 2022, 22 (15)
  • [50] Characterization of the microstructures of specialty optical fibers for electric-field sensing by propagation-based x-ray phase-contrast microtomography
    Colaco, Marcos, V
    Camara, Alexandre R.
    Nogueira, Liebert P.
    Carvalho, Isabel C. S.
    Margulis, Walter
    Barroso, Regina C.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (06)