Standardized anthropological measurement of postcranial bones using three-dimensional models in CAD software

被引:12
作者
Reynolds, Mikaela S. [1 ]
MacGregor, Donna M. [1 ]
Barry, Mark D. [2 ]
Lottering, Nicolene [3 ]
Schmutz, Beat [4 ]
Wilson, Lance J. [5 ]
Meredith, Matthew [6 ]
Gregory, Laura S. [1 ]
机构
[1] Queensland Univ Technol, Fac Hlth, Sch Biomed Sci, Brisbane, Qld, Australia
[2] Univ Sunshine Coast, Fac Sci Hlth Educ & Engn, Visualisat Facil, Sippy Downs, Qld, Australia
[3] Univ Adelaide, Sch Med, Adelaide, SA, Australia
[4] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld, Australia
[5] Monash Univ, Multimodal Australian Sci Imaging & Visualisat En, Clayton, Vic, Australia
[6] Queensland Hlth Forens & Sci Serv, Forens Pathol, Coopers Plains, Qld, Australia
关键词
Forensic anthropology; Multi-slice computed tomography; Reverse engineering; Technical error of measurement; Precision; Observer-agreement; MULTIDETECTOR COMPUTED-TOMOGRAPHY; LEG LENGTH DISCREPANCY; RELIABILITY; CT; ACCURACY; LIMB; AGE;
D O I
10.1016/j.forsciint.2017.07.015
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
This study introduces a standardized protocol for conducting linear measurements of postcranial skeletal elements using three-dimensional (3D) models constructed from post-mortem computed tomography (PMCT) scans. Using femoral DICOM datasets, reference planes were generated and plane-to-plane measurements were conducted on 3D surface rendered models. Bicondylar length, epicondylar breadth, anterior-posterior (AP) diameter, medial-lateral (ML) diameter and cortical area at the midshaft were measured by four observers to test the measurement error variance and observer agreement of the protocol (n = 6). Intra-observer error resulted in a mean relative technical error of measurement (%TEM) of 0.11 and an intraclass correlation coefficient (ICC) of 0.999 (CI = 0.998-1.000); inter-observer error resulted in a mean %TEM of 0.54 and ICC of 0.996 (CI = 0.979-1.000) for bicondylar length. Epicondylar breadth, AP diameter, ML diameter and cortical area also yielded minimal error. Precision testing demonstrated that the approach is highly repeatable and is recommended for implementation in anthropological investigation and research. This study exploits the benefits of virtual anthropology, introducing an innovative, standardized alternative to dry bone osteometric measurements. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 50 条
  • [21] A novel standardized distraction test to evaluate lower eyelid tension using three-dimensional stereophotogrammetry
    Hou, Xiaoyi
    Rokohl, Alexander C.
    Meinke, Marius M.
    Li, Senmao
    Liu, Jinhua
    Fan, Wanlin
    Lin, Ming
    Jia, Renbing
    Guo, Yongwei
    Heindl, Ludwig M.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (08) : 3735 - 3748
  • [22] Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
    Gihyeon Kim
    Ho-Joong Jung
    Han-Jun Lee
    Jae-Sung Lee
    Seungbum Koo
    Seung-Hwan Chang
    Journal of Digital Imaging, 2012, 25 : 486 - 491
  • [23] Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
    Kim, Gihyeon
    Jung, Ho-Joong
    Lee, Han-Jun
    Lee, Jae-Sung
    Koo, Seungbum
    Chang, Seung-Hwan
    JOURNAL OF DIGITAL IMAGING, 2012, 25 (04) : 486 - 491
  • [24] Measurement consistency and three-dimensional electromechanical anthropometry
    Feathers, DJ
    Paquet, VL
    Drury, CG
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2004, 33 (03) : 181 - 190
  • [25] Digital Photogrammetry for Assessing Medial Canthal Tendon Laxity: Novel Standardized Three-Dimensional Versus Traditional Two-Dimensional Lateral Distraction Test
    Hou, Xiaoyi
    Rokohl, Alexander C.
    Meinke, Marius M.
    Zhang, Ming
    Guo, Yongwei
    Heindl, Ludwig M.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 80 (06) : 1033 - 1039
  • [26] Comparative Study of Cranial Anthropometric Measurement by Traditional Calipers to Computed Tomography and Three-dimensional Photogrammetry
    Mendonca, Derick A.
    Naidoo, Sybill D.
    Skolnick, Gary
    Skladman, Rachel
    Woo, Albert S.
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (04) : 1106 - 1110
  • [27] Three-dimensional surface models of the facial soft tissues acquired with a low-cost scanner
    Maues, C. P. R.
    Casagrande, M. V. S.
    Almeida, R. C. C.
    Almeida, M. A. O.
    Carvalho, F. A. R.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 47 (09) : 1219 - 1225
  • [28] Reliability and reproducibility of three-dimensional cephalometric landmarks using CBCT: a systematic review
    Lisboa, Cinthia de Oliveira
    Masterson, Daniele
    Jardim da Motta, Andrea Fonseca
    Motta, Alexandre Trindade
    JOURNAL OF APPLIED ORAL SCIENCE, 2015, 23 (02) : 112 - 119
  • [29] Anthropometric Evaluation of Periorbital Region and Facial Projection Using Three-Dimensional Photogrammetry
    Jodeh, Diana S.
    Curtis, Heather
    Cray, James J.
    Ford, Jonathan
    Decker, Summer
    Rottgers, S. Alex
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2017 - 2020
  • [30] Three-Dimensional Spinal Evaluation Using Rasterstereography in Patients with Adolescent Idiopathic Scoliosis: Is It Closer to Three-Dimensional or Two-Dimensional Radiography?
    Tabard-Fougere, Anne
    de Bodman, Charlotte
    Dhouib, Amira
    Bonnefoy-Mazure, Alice
    Armand, Stephane
    Dayer, Romain
    DIAGNOSTICS, 2023, 13 (14)