Impact of beating heart left atrial ablation on left-sided heart mechanics

被引:3
作者
Ota, Takeyoshi
Schwartzman, David
Francischelli, David
Hettrick, Douglas A.
Zenati, Marco A.
机构
[1] Univ Pittsburgh, Div Cardiac Surg, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Cardiovasc Inst, Pittsburgh, PA 15213 USA
[3] Medtronic Inc, Minneapolis, MN USA
关键词
D O I
10.1016/j.jtcvs.2007.04.063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The cut-and-sew Cox-Maze procedure is the gold standard for surgical treatment of atrial fibrillation, but it is associated with long-term impairment of left atrial mechanical function. We developed a bipolar, irrigated radiofrequency ablation device. We hypothesized that beating heart radiofrequency left atrial ablation would result in minimal acute changes in left atrial hemodynamics. Methods: Six healthy subjects were studied. Combination pressure-conductance catheters were inserted into the left atrium and ventricle. With the use of the device, atrial ablation was performed on the beating heart without cardiopulmonary bypass, including electrical isolation of the posterior left atrium and atrial appendage myocardium. Simultaneous left-sided heart pressure-volume and intracardiac echocardiography data were acquired before ablation, after left atrial appendage ablation alone, and after all ablation (with and without appendage occlusion). The derived indices of left-sided heart mechanical function were examined. Results: Relative to baseline, no significant diminishment in pressure-volume or intracardiac echocardiography- derived indices of global left-sided heart mechanical function were observed after ablation, with or without appendage occlusion. Mitral valve morphology and function were not significantly altered. A significant diminishment of atrial appendage systolic flow was noted after appendage ablation in association with spontaneous echocardiographic contrast in this region. Conclusions: In this model, ablation does not seem to compromise global left-sided heart mechanical function. However, these findings mask regional diminishment in atrial appendage systolic function. This observation demonstrates that electrical isolation of the appendage should be accompanied by its occlusion or excision. Appendage occlusion after ablation does not seem to compromise left- sided heart mechanical function.
引用
收藏
页码:982 / 988
页数:7
相关论文
共 21 条
  • [1] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [2] QUANTITATION OF MITRAL REGURGITATION BY DOPPLER ECHOCARDIOGRAPHY
    BLUMLEIN, S
    BOUCHARD, A
    SCHILLER, NB
    DAE, M
    BYRD, BF
    PORTS, T
    BOTVINICK, EH
    [J]. CIRCULATION, 1986, 74 (02) : 306 - 314
  • [3] A new device for beating heart bipolar radio frequency atrial ablation
    Bonanomi, G
    Schwartzman, D
    Francischelli, D
    Hebsgaard, K
    Zenati, MA
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (06) : 1859 - 1866
  • [4] MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT ATRIAL APPENDAGE ANATOMY AND FUNCTION
    CHAN, SK
    KANNAM, JP
    DOUGLAS, PS
    MANNING, WJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (07) : 528 - &
  • [5] COMPLIANCE OF LEFT ATRIUM WITH AND WITHOUT LEFT ATRIUM APPENDAGE
    DAVIS, CA
    REMBERT, JC
    GREENFIELD, JC
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (04): : H1006 - H1008
  • [6] Left atrial mechanical adaptation to long-standing hemodynamic loads based on pressure-volume relations
    Dernellis, JM
    Stefanadis, CI
    Zacharoulis, AA
    Toutouzas, PK
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (09) : 1138 - 1143
  • [7] FEINBERG MS, 1994, CIRCULATION, V90, P285
  • [8] ALTERED LEFT ATRIAL COMPLIANCE AFTER ATRIAL APPENDECTOMY - INFLUENCE ON LEFT ATRIAL AND VENTRICULAR FILLING
    HOIT, BD
    SHAO, YF
    TSAI, LM
    PATEL, R
    GABEL, M
    WALSH, RA
    [J]. CIRCULATION RESEARCH, 1993, 72 (01) : 167 - 175
  • [9] Jue J, 1993, J Am Soc Echocardiogr, V6, P237
  • [10] Validation of a left atrial lesion pattern for intraoperative ablation of atrial fibrillation
    Kress, DC
    Krum, D
    Chekanov, V
    Hare, J
    Michaud, N
    Akhtar, M
    Sra, J
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (04) : 1160 - 1168