Development of a qualitative/quantitative strategy for comprehensive determination of polar lipids by LC-MS/MS in human plasma

被引:13
|
作者
Lopez-Bascon, M. A. [1 ,2 ,3 ,4 ]
Calderon-Santiago, M. [1 ,2 ,3 ,4 ]
Diaz-Lozano, A. [1 ,2 ,3 ,4 ]
Camargo, A. [2 ,5 ]
Lopez-Miranda, J. [2 ,5 ]
Priego-Capote, F. [1 ,2 ,3 ,4 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
[2] Univ Cordoba, Maimonides Inst Biomed Res IMIBIC, Reina Sofia Univ Hosp, E-14004 Cordoba, Spain
[3] Univ Cordoba, CeiA3 Agroalimentary Excellence Campus, E-14071 Cordoba, Spain
[4] Inst Salud Carlos III, CIBERfes, Madrid 28220, Spain
[5] Inst Salud Carlos III, CIBER Fisiopatol Obesidad & Nutr CIBEROBN, Madrid 28220, Spain
基金
欧盟地平线“2020”;
关键词
Lipidomics; Polar lipids; LC; MS; Plasma; Multiple reaction monitoring; TANDEM MASS-SPECTROMETRY; PHASE LIQUID-CHROMATOGRAPHY; ELECTROSPRAY-IONIZATION; LIPIDOMICS ANALYSIS; FATTY-ACID; LYSOPHOSPHOLIPIDS; QUANTIFICATION; IDENTIFICATION; GLYCEROPHOSPHOLIPIDS; SPHINGOMYELINS;
D O I
10.1007/s00216-019-02261-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polar lipids, especially glycerophospholipids, constitute the main components of cell membranes and are precursors of signaling molecules in many cellular and physiological processes. For this reason, the development of methods with high capability for detection of polar lipids in biological samples is required. In this research, the objective was to develop a method for comprehensive qualitative/quantitative determination of polar lipids in plasma by a combination of acquisition methods with a triple quadrupole mass analyzer. The strategy was optimized in two steps: (a) a first step for detection of lipids by monitoring selective fragmentation patterns representative of each lipid family and (b) a second step for confirmation of lipid species by detection and identification of product ions associated with the conjugated fatty acids. The acquisition list was divided into two multiple reaction monitoring (MRM) methods to ensure the detection of all transitions with suited instrumental sensitivity according to chromatographic retention time and relative abundance in plasma. The combination of the two MRM methods allowed the detection of 398 polar lipids in plasma in 64 min. Precision, estimated as within-day variability, was below 6.8% for all determined lipid families, while between-day variability was below 24.0%. This strategy has been applied to a cohort formed by 384 individuals in order to obtain a qualitative and quantitative distribution of polar lipids in human plasma. The most concentrated lipid families in relative terms were lysophospholipids, plasmalogens, and phosphatydilcholines, with mean relative concentration of 58.0, 17.1, and 8.3%, respectively. Then, sphingomyelins and phosphatidylethanolamines reported a relative concentration of 2.0%, followed by phosphatidylserines, with 1.1%.
引用
收藏
页码:489 / 498
页数:10
相关论文
共 50 条
  • [21] Determination of penicillins in milk using LC-UV, LC-MS and LC-MS/MS
    Martinez-Huelamo, Miriam
    Jimenez-Gamez, Esther
    Pilar Hermo, Maria
    Barron, Dolores
    Barbosa, Jose
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (14) : 2385 - 2393
  • [22] Protein Precipitation Method for Determination of Zileuton in Human Plasma by LC-MS/MS
    Armoudjian, Yeghig
    Mikayelyan, Astghik
    Zakaryan, Hasmik
    Aleksanyan, Armine
    Alaverdyan, Harutyun
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2020, 15 (04) : 581 - 590
  • [23] Analytical Challenges: Determination of Tetrodotoxin in Human Urine and Plasma by LC-MS/MS
    Leung, Kelvin Sze-Yin
    Fong, Bonnie Mei-Wah
    Tsoi, Yeuk-Ki
    MARINE DRUGS, 2011, 9 (11): : 2291 - 2303
  • [24] Development and validation of a sensitive LC-MS/MS method for the determination of D-serine in human plasma
    Xie, Y.
    Alexander, G. M.
    Schwartzman, R. J.
    Singh, N.
    Torjman, M. C.
    Goldberg, M. E.
    Wainer, I. W.
    Moaddel, R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 : 1 - 5
  • [25] Validated LC-MS/MS assay for the quantitative determination of vardenafil in human plasma and its application to a pharmacokinetic study
    Lake, Simon T.
    Altman, Phillip M.
    Vaisman, Jack
    Addison, Russell S.
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (08) : 846 - 851
  • [26] Development of a LC-MS/MS Method for the Determination of Dasatinib in Rat Plasma
    Cao, Shan-feng
    Wang, Xiao-min
    Zheng, Liu-chuang
    Sun, Ming
    Wang, Ying-fei
    Fan, Rui-tai
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (03): : 542 - 546
  • [27] Development and validation of LC-MS/MS method for determination of plasma apixaban
    Dzudovic, Jelena
    Sakac, Milkica Crevar
    Antunovic, Marko
    Repic, Aleksandra
    Obradovic, Slobodan
    Djordjevic, Snezana
    Savic, Jelena
    Dzudovic, Boris
    ACTA CHROMATOGRAPHICA, 2022, 34 (03) : 332 - 337
  • [28] LC-MS-MS Development and Validation for Quantitative Determination of Methoxsalen in Human Plasma
    Gomes, Noel Alex
    Vaidya, Vikas V.
    Pudage, Ashutosh M.
    Joshi, Santosh S.
    Laud, Avdhoot M.
    Basagare, Snehal
    Tandel, Jayram A.
    CHROMATOGRAPHIA, 2009, 69 (9-10) : 1061 - 1065
  • [29] Development and validation of a novel LC-MS/MS method for simultaneous quantitative determination of tyrosine kinase inhibitors in human plasma
    Lou, Yutao
    Qin, Hui
    Hu, Qing
    Chai, Yitao
    Zhou, Hongying
    Chen, Mengting
    Wang, Qiyue
    Huang, Ping
    Gu, Jinping
    Zhang, Yiwen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1208
  • [30] LC-MS-MS Development and Validation for Quantitative Determination of Methoxsalen in Human Plasma
    Noel Alex Gomes
    Vikas V. Vaidya
    Ashutosh M. Pudage
    Santosh S. Joshi
    Avdhoot M. Laud
    Snehal Basagare
    Jayram A. Tandel
    Chromatographia, 2009, 69 : 1061 - 1065