An audit of high dose-rate prostate brachytherapy treatment planning at six Swedish clinics

被引:1
|
作者
Dohlmar, Frida [1 ]
Johansson, Sakarias [2 ]
Larsson, Torbjorn [3 ]
Sandborg, Michael [1 ,4 ]
Tedgren, Asa Carlsson [1 ,4 ,5 ,6 ]
机构
[1] Linkoping Univ, Dept Hlth Med & Caring Sci, Med Radiat Phys, Linkoping, Sweden
[2] Karolinska Univ Hosp, Dept Oncol, Stockholm, Sweden
[3] Linkoping Univ, Dept Math, Linkoping, Sweden
[4] Linkoping Univ, CMIV, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[5] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
[6] Karolinska Inst, Dept Oncol Pathol, Stockholm, Sweden
关键词
brachytherapy; audit; dosimetric indices; EXTERNAL-BEAM RADIOTHERAPY; RATE IR-192 BRACHYTHERAPY; OPTIMIZATION ALGORITHMS; INVERSE OPTIMIZATION; GEOMETRIC OPTIMIZATION; GRAPHICAL OPTIMIZATION; CANCER; IRRADIATION; DOSIMETRY; IPSA;
D O I
10.5114/jcb.2021.103588
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: High dose-rate prostate brachytherapy has been implemented in Sweden in the late 1980s and early 1990s in six clinics using the same schedule: 20 Gy in two fractions combined with 50 Gy in 25 fractions with external beam radiation therapy. Thirty years have passed and during these years, various aspects of the treatment process have developed, such as ultrasound-guided imaging and treatment planning system. An audit was conducted, including a questionnaire and treatment planning, which aimed to gather knowledge about treatment planning methods in Swedish clinics. Material and methods: A questionnaire and a treatment planning case (non-anatomical images) were sent to six Swedish clinics, in which high-dose-rate prostate brachytherapy is performed. Treatment plans were compared using dosimetric indices and equivalent 2 Gy doses (EQD(2)). Treatment planning system report was used to compare dwell positions and dwell times. Results: For all the clinics, the planning aim for the target was 10.0 Gy, but the volume to receive the dose differed from 95% to 100%. Dose constraints for organs at risk varied with up to 2 Gy. The dose to 90% of target volume ranged from 10.0 Gy to 11.1 Gy, equivalent to 26.0 Gy EQD(2) and 31.3 Gy EQD(2), respectively. Dose non-homogeneity ratio differed from 0.18 to 0.32 for clinical target volume (CTV) in treatment plans and conformity index ranged from 0.52 to 0.59 for CTV. Conclusions: Dose constraints for the organs at risk are showing a larger variation than that reflected in compared treatments plans. In all treatment plans in our audit, at least 10 Gy was administered giving a total treatment of 102 Gy EQD(2), which is in the upper part of the prescription doses published in the GEC/ESTRO recommendations.
引用
收藏
页码:59 / 71
页数:13
相关论文
共 50 条
  • [31] Postoperative endoscopic retrograde high dose-rate brachytherapy for cholangiocarcinoma
    Ove, R
    Kennedy, A
    Darwin, P
    Haluszka, O
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2000, 23 (06): : 559 - 561
  • [32] High dose rate brachytherapy as a boost for the treatment of localized prostate cancer
    Phan, Thinh P.
    Syed, A. M. Nisar
    Puthawala, Ajmel
    Sharma, Anil
    Khan, Farhan
    JOURNAL OF UROLOGY, 2007, 177 (01) : 123 - 127
  • [33] FRACTIONATED HIGH DOSE-RATE VERSUS LOW DOSE-RATE REGIMENS FOR INTRACAVITARY BRACHYTHERAPY OF THE CERVIX - EQUIVALENT REGIMENS FOR COMBINED BRACHYTHERAPY AND EXTERNAL IRRADIATION
    BRENNER, DJ
    HUANG, Y
    HALL, EJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (06): : 1415 - 1423
  • [34] High dose rate brachytherapy for prostate cancer
    Hoskin, P.
    CANCER RADIOTHERAPIE, 2008, 12 (6-7): : 512 - 514
  • [35] Application and benchmarking of multi-objective evolutionary algorithms on high-dose-rate brachytherapy planning for prostate cancer treatment
    Ngoc Hoang Luong
    Alderliesten, Tanja
    Bel, Arjan
    Niatsetski, Yury
    Bosman, Peter A. N.
    SWARM AND EVOLUTIONARY COMPUTATION, 2018, 40 : 37 - 52
  • [36] OPTIMIZATION OF HIGH DOSE-RATE CERVIX BRACHYTHERAPY .1. DOSE DISTRIBUTION
    HOUDEK, PV
    SCHWADE, JG
    ABITBOL, AA
    PISCIOTTA, V
    WU, XD
    SERAGO, CF
    MARKOE, AM
    LEWIN, AA
    AVERETTE, HE
    SEVIN, BU
    BRANDON, AH
    FIEDLER, JA
    COHEN, AM
    FAYAD, F
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (06): : 1621 - 1625
  • [37] Decision regret after external beam radiotherapy and high dose-rate brachytherapy boost for prostate cancer
    Lars Haack
    David Krug
    Severin Rodler
    Philipp Nuhn
    Christof van der Horst
    Christian Schulz
    Olaf Wittenstein
    Claudia Schmalz
    Oliver Blanck
    Frank-André Siebert
    Alexander Fabian
    World Journal of Urology, 43 (1)
  • [38] Accuracy in catheter reconstruction in computed tomography planning of high dose rate prostate brachytherapy
    Fung, AYC
    Zaider, M
    MEDICAL PHYSICS, 2000, 27 (09) : 2165 - 2167
  • [39] Accuracy in catheter reconstruction in computed tomography planning of high dose rate prostate brachytherapy
    Fung, AYC
    Zaider, M
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2685 - 2688
  • [40] Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy: Feasibility and Initial Experiences Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy
    Lakosi, Ferenc
    Antal, Gergely
    Vandulek, Csaba
    Kovacs, Arpad
    Toller, Gabor L.
    Rakasz, Istvan
    Bajzik, Gabor
    Hadjiev, Janaki
    Bogner, Peter
    Repa, Imre
    PATHOLOGY & ONCOLOGY RESEARCH, 2011, 17 (02) : 315 - 324