An audit of high dose-rate prostate brachytherapy treatment planning at six Swedish clinics

被引:1
|
作者
Dohlmar, Frida [1 ]
Johansson, Sakarias [2 ]
Larsson, Torbjorn [3 ]
Sandborg, Michael [1 ,4 ]
Tedgren, Asa Carlsson [1 ,4 ,5 ,6 ]
机构
[1] Linkoping Univ, Dept Hlth Med & Caring Sci, Med Radiat Phys, Linkoping, Sweden
[2] Karolinska Univ Hosp, Dept Oncol, Stockholm, Sweden
[3] Linkoping Univ, Dept Math, Linkoping, Sweden
[4] Linkoping Univ, CMIV, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[5] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
[6] Karolinska Inst, Dept Oncol Pathol, Stockholm, Sweden
关键词
brachytherapy; audit; dosimetric indices; EXTERNAL-BEAM RADIOTHERAPY; RATE IR-192 BRACHYTHERAPY; OPTIMIZATION ALGORITHMS; INVERSE OPTIMIZATION; GEOMETRIC OPTIMIZATION; GRAPHICAL OPTIMIZATION; CANCER; IRRADIATION; DOSIMETRY; IPSA;
D O I
10.5114/jcb.2021.103588
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: High dose-rate prostate brachytherapy has been implemented in Sweden in the late 1980s and early 1990s in six clinics using the same schedule: 20 Gy in two fractions combined with 50 Gy in 25 fractions with external beam radiation therapy. Thirty years have passed and during these years, various aspects of the treatment process have developed, such as ultrasound-guided imaging and treatment planning system. An audit was conducted, including a questionnaire and treatment planning, which aimed to gather knowledge about treatment planning methods in Swedish clinics. Material and methods: A questionnaire and a treatment planning case (non-anatomical images) were sent to six Swedish clinics, in which high-dose-rate prostate brachytherapy is performed. Treatment plans were compared using dosimetric indices and equivalent 2 Gy doses (EQD(2)). Treatment planning system report was used to compare dwell positions and dwell times. Results: For all the clinics, the planning aim for the target was 10.0 Gy, but the volume to receive the dose differed from 95% to 100%. Dose constraints for organs at risk varied with up to 2 Gy. The dose to 90% of target volume ranged from 10.0 Gy to 11.1 Gy, equivalent to 26.0 Gy EQD(2) and 31.3 Gy EQD(2), respectively. Dose non-homogeneity ratio differed from 0.18 to 0.32 for clinical target volume (CTV) in treatment plans and conformity index ranged from 0.52 to 0.59 for CTV. Conclusions: Dose constraints for the organs at risk are showing a larger variation than that reflected in compared treatments plans. In all treatment plans in our audit, at least 10 Gy was administered giving a total treatment of 102 Gy EQD(2), which is in the upper part of the prescription doses published in the GEC/ESTRO recommendations.
引用
收藏
页码:59 / 71
页数:13
相关论文
共 50 条
  • [21] Prostate segmentation accuracy using synthetic MRI for high-dose-rate prostate brachytherapy treatment planning
    Kang, Hyejoo
    Podgorsak, Alexander R.
    Venkatesulu, Bhanu Prasad
    Saripalli, Anjali L.
    Chou, Brian
    Solanki, Abhishek A.
    Harkenrider, Matthew
    Shea, Steven
    Roeske, John C.
    Abuhamad, Mohammed
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (15)
  • [22] Role of high dose rate brachytherapy in the treatment of prostate cancer
    Ghilezan, M.
    CANCER RADIOTHERAPIE, 2012, 16 (5-6): : 418 - 422
  • [23] Exploration of gynaecological cancer high dose-rate brachytherapy treatment: a pilot study
    Ehlers, Alicia
    Makanjee, Chandra Rekha
    PAN AFRICAN MEDICAL JOURNAL, 2018, 30
  • [24] Fricke gel-layer dosimetry in high dose-rate brachytherapy
    Carrara, M.
    Fallai, C.
    Gambarini, G.
    Negri, A.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 722 - 725
  • [25] Overview of treatment plan quality in a high dose rate prostate brachytherapy workflow
    Panetta, J. V.
    Veltchev, I.
    Horwitz, E.
    Hallman, M.
    Wong, K.
    Price, R. A.
    Ma, C. M. C.
    BRACHYTHERAPY, 2024, 23 (06) : 698 - 704
  • [26] Automatic bi-objective parameter tuning for inverse planning of high-dose-rate prostate brachytherapy
    Maree, S. C.
    Bosman, P. A. N.
    van Wieringen, N.
    Niatsetski, Y.
    Pieters, B. R.
    Bel, A.
    Alderliesten, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (07)
  • [27] Knowledge-based inverse treatment planning for low-dose-rate prostate brachytherapy
    Guthier, Christian V.
    Orio, Peter F., III
    Buzurovic, Ivan
    Cormack, Robert A.
    MEDICAL PHYSICS, 2021, 48 (05) : 2108 - 2117
  • [28] Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy
    Poulin, Eric
    Varfalvy, Nicolas
    Aubin, Sylviane
    Beaulieu, Luc
    BRACHYTHERAPY, 2016, 15 (01) : 102 - 111
  • [29] Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements
    Poder, Joel
    Whitaker, May
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (03) : 203 - 209
  • [30] Physics of Pulsed Dose-Rate brachytherapy
    Hensley, FW
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2305 - 2307