An audit of high dose-rate prostate brachytherapy treatment planning at six Swedish clinics

被引:1
|
作者
Dohlmar, Frida [1 ]
Johansson, Sakarias [2 ]
Larsson, Torbjorn [3 ]
Sandborg, Michael [1 ,4 ]
Tedgren, Asa Carlsson [1 ,4 ,5 ,6 ]
机构
[1] Linkoping Univ, Dept Hlth Med & Caring Sci, Med Radiat Phys, Linkoping, Sweden
[2] Karolinska Univ Hosp, Dept Oncol, Stockholm, Sweden
[3] Linkoping Univ, Dept Math, Linkoping, Sweden
[4] Linkoping Univ, CMIV, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[5] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
[6] Karolinska Inst, Dept Oncol Pathol, Stockholm, Sweden
关键词
brachytherapy; audit; dosimetric indices; EXTERNAL-BEAM RADIOTHERAPY; RATE IR-192 BRACHYTHERAPY; OPTIMIZATION ALGORITHMS; INVERSE OPTIMIZATION; GEOMETRIC OPTIMIZATION; GRAPHICAL OPTIMIZATION; CANCER; IRRADIATION; DOSIMETRY; IPSA;
D O I
10.5114/jcb.2021.103588
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: High dose-rate prostate brachytherapy has been implemented in Sweden in the late 1980s and early 1990s in six clinics using the same schedule: 20 Gy in two fractions combined with 50 Gy in 25 fractions with external beam radiation therapy. Thirty years have passed and during these years, various aspects of the treatment process have developed, such as ultrasound-guided imaging and treatment planning system. An audit was conducted, including a questionnaire and treatment planning, which aimed to gather knowledge about treatment planning methods in Swedish clinics. Material and methods: A questionnaire and a treatment planning case (non-anatomical images) were sent to six Swedish clinics, in which high-dose-rate prostate brachytherapy is performed. Treatment plans were compared using dosimetric indices and equivalent 2 Gy doses (EQD(2)). Treatment planning system report was used to compare dwell positions and dwell times. Results: For all the clinics, the planning aim for the target was 10.0 Gy, but the volume to receive the dose differed from 95% to 100%. Dose constraints for organs at risk varied with up to 2 Gy. The dose to 90% of target volume ranged from 10.0 Gy to 11.1 Gy, equivalent to 26.0 Gy EQD(2) and 31.3 Gy EQD(2), respectively. Dose non-homogeneity ratio differed from 0.18 to 0.32 for clinical target volume (CTV) in treatment plans and conformity index ranged from 0.52 to 0.59 for CTV. Conclusions: Dose constraints for the organs at risk are showing a larger variation than that reflected in compared treatments plans. In all treatment plans in our audit, at least 10 Gy was administered giving a total treatment of 102 Gy EQD(2), which is in the upper part of the prescription doses published in the GEC/ESTRO recommendations.
引用
收藏
页码:59 / 71
页数:13
相关论文
共 50 条
  • [1] High dose-rate brachytherapy in the treatment of prostate cancer
    Mendez, Lucas C.
    Morton, Gerard C.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2018, 7 (03) : 357 - 370
  • [2] Dose Distribution of High Dose-Rate and Low Dose-Rate Prostate Brachytherapy at Different Intervals-Impact of a Hydrogel Spacer and Prostate Volume
    Haddad, Hathal
    Hermani, Horst
    Hanitzsch, Herbert
    Heidrich, Albert
    Pinkawa, Michael
    CANCERS, 2023, 15 (05)
  • [3] High dose rate prostate brachytherapy
    Nickers, P.
    Blanchard, P.
    Hannoun-Levi, J-M
    Bossi, A.
    Chapet, O.
    Guerif, S.
    CANCER RADIOTHERAPIE, 2013, 17 (02): : 118 - 124
  • [4] Prostate cancer high dose-rate brachytherapy: review of evidence and current perspectives
    Dutta, Sunil W.
    Alonso, Clayton E.
    Libby, Bruce
    Showalter, Timothy N.
    EXPERT REVIEW OF MEDICAL DEVICES, 2018, 15 (01) : 71 - 79
  • [5] Personalised in silico biomechanical modelling towards the optimisation of high dose-rate brachytherapy planning and treatment against prostate cancer
    Hadjicharalambous, Myrianthi
    Roussakis, Yiannis
    Bourantas, George
    Ioannou, Eleftherios
    Miller, Karol
    Doolan, Paul
    Strouthos, Iosif
    Zamboglou, Constantinos
    Vavourakis, Vasileios
    FRONTIERS IN PHYSIOLOGY, 2024, 15
  • [6] DOSE DETERMINATION IN HIGH DOSE-RATE BRACHYTHERAPY
    HOUDEK, PV
    SCHWADE, JG
    WU, XD
    PISCIOTTA, V
    FIEDLER, JA
    SERAGO, CF
    MARKOE, AM
    ABITBOL, AA
    LEWIN, AA
    BRAUNSCHWEIGER, PG
    SKLAR, MD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (04): : 795 - 801
  • [7] Salvage high dose-rate brachytherapy for local recurrence of prostate cancer after different types of radical treatment
    Solodkiy, V. A.
    Pavlov, A. Yu
    Tsybulskiy, A. D.
    Dzidzariya, A. G.
    Pchelintsev, A. S.
    ONKOUROLOGIYA, 2019, 15 (02): : 73 - 76
  • [8] High dose-rate afterloading 192Iridium prostate brachytherapy:: Feasibility report
    Mate, TP
    Gottesman, JE
    Hatton, J
    Gribble, M
    Van Hollebeke, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03): : 525 - 533
  • [9] High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer
    Ghadjar, Pirus
    Bojaxhiu, Beat
    Simcock, Mathew
    Terribilini, Dario
    Isaak, Bernhard
    Gut, Philipp
    Wolfensberger, Patrick
    Broemme, Jens O.
    Geretschlaeger, Andreas
    Behrensmeier, Frank
    Pica, Alessia
    Aebersold, Daniel M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04): : 1205 - 1212
  • [10] Biologic treatment planning for high-dose-rate brachytherapy
    Manning, MA
    Zwicker, RD
    Arthur, DW
    Arnfield, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 839 - 845