Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study

被引:121
作者
Tabassum, Afsheen [1 ]
Meijer, Gert J. [1 ]
Wolke, Johannes G. C. [1 ]
Jansen, John A. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Periodontol & Biomat, NL-6500 HB Nijmegen, Netherlands
关键词
cortical thickness; dental implants; primary stability; surface roughness; surgical technique; OSSEOINTEGRATED ORAL IMPLANTS; DENTAL QUANTITATIVE CT; ACID-ETCHED SURFACE; IN-VITRO; TITANIUM IMPLANTS; MINERAL DENSITY; MANDIBULAR BONE; FINITE-ELEMENT; PLACEMENT; INSERTION;
D O I
10.1111/j.1600-0501.2009.01823.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The aim of this biomechanical study was to assess the interrelated effect of both surface roughness and surgical technique on the primary stability of dental implants. Material and methods For the experiment, 160 screw-designed implants (Biocomp (R)), with either a machined or an etched surface topography, were inserted into polyurethane foam blocks (Sawbones (R)). As an equivalent of trabecular bone, a density of 0.48 g/cm3 was chosen. To mimic the cortical layer, on top of these blocks short-fibre-filled epoxy sheets were attached with a thickness varying from 0 to 2.5 mm. The implant sites were prepared using either a press-fit or an undersized technique. To measure the primary stability of the implant, both the insertion and the removal torques were scored. Results Independent of the surgical technique used, both implant types showed an increased insertion and removal torque values with increasing cortical thickness, although > 2 mm cortical layer no further increase in insertion torque was observed. In the models with only trabecular bone (without cortical layer) and with a 1 mm cortical layer, both implant types showed a statistically higher insertion and removal torque values for undersized compared with the press-fit technique. In addition, etched implants showed a statistically higher insertion and removal torque mean values compared with machined implants. In the models with 2 and 2.5 mm cortical layers, with respect to the insertion torque values, no effect of either implantation technique or implant surface topography could be observed. Conclusion The placement of etched implants in synthetic bone models using an undersized preparation technique resulted in enhanced primary implant stability. A correlation was found between the primary stability and the cortical thickness. However, at or above a cortical thickness of 2 mm, the effect of both an undersized surgical approach, as also the presence of a roughened (etched) implant surface, had no extra effect. Besides the mechanical aspects, the biological effect of undersized drilling, i.e. the bone response on the extra insertion torque forces should also be elucidated. Therefore, additional in vivo studies are needed. To cite this article:Tabassum A, Meijer GJ, Wolke JGC, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.Clin. Oral Impl. Res. 21, 2010; 213-220.doi: 10.1111/j.1600-0501.2009.01823.x.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 55 条
  • [31] Significance of primary stability for osseointegration of dental implants
    Lioubavina-Hack, N
    Lang, NP
    Karring, T
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (03) : 244 - 250
  • [32] Meredith N, 1998, INT J PROSTHODONT, V11, P491
  • [33] Influence of cortical bone thickness and implant length on implant stability at the time of surgery - clinical, prospective, biomechanical, and imaging study
    Miyamoto, I
    Tsuboi, Y
    Wada, E
    Suwa, H
    Iizuka, T
    [J]. BONE, 2005, 37 (06) : 776 - 780
  • [34] Motoyoshi M, 2007, INT J ORAL MAX IMPL, V22, P779
  • [35] Effects of titanium surfaces blasted with TiO2 particles on the initial attachment of cells derived from human mandibular bone -: A scanning electron microscopic and histomorphometric analysis
    Mustafa, K
    Wroblewski, J
    Hultenby, K
    Lopez, BS
    Arvidson, K
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (02) : 116 - 128
  • [36] Implant stability and histomorphometry:: a correlation study in human cadavers using stepped cylinder implants
    Nkenke, E
    Hahn, M
    Weinzierl, K
    Radespiel-Tröger, M
    Neukam, FW
    Engelke, K
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (05) : 601 - 609
  • [37] Bone classification: an objective scale of bone density using the computerized tomography scan
    Norton, MR
    Gamble, C
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) : 79 - 84
  • [38] O'Sullivan Dominic, 2004, Clin Implant Dent Relat Res, V6, P48, DOI 10.1111/j.1708-8208.2004.tb00027.x
  • [39] Saadoun Andre P, 2004, Pract Proced Aesthet Dent, V16, P529
  • [40] SAADOUN AP, 2004, PRACTICAL PROCEDURES, V16, P521