Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study

被引:121
作者
Tabassum, Afsheen [1 ]
Meijer, Gert J. [1 ]
Wolke, Johannes G. C. [1 ]
Jansen, John A. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Periodontol & Biomat, NL-6500 HB Nijmegen, Netherlands
关键词
cortical thickness; dental implants; primary stability; surface roughness; surgical technique; OSSEOINTEGRATED ORAL IMPLANTS; DENTAL QUANTITATIVE CT; ACID-ETCHED SURFACE; IN-VITRO; TITANIUM IMPLANTS; MINERAL DENSITY; MANDIBULAR BONE; FINITE-ELEMENT; PLACEMENT; INSERTION;
D O I
10.1111/j.1600-0501.2009.01823.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The aim of this biomechanical study was to assess the interrelated effect of both surface roughness and surgical technique on the primary stability of dental implants. Material and methods For the experiment, 160 screw-designed implants (Biocomp (R)), with either a machined or an etched surface topography, were inserted into polyurethane foam blocks (Sawbones (R)). As an equivalent of trabecular bone, a density of 0.48 g/cm3 was chosen. To mimic the cortical layer, on top of these blocks short-fibre-filled epoxy sheets were attached with a thickness varying from 0 to 2.5 mm. The implant sites were prepared using either a press-fit or an undersized technique. To measure the primary stability of the implant, both the insertion and the removal torques were scored. Results Independent of the surgical technique used, both implant types showed an increased insertion and removal torque values with increasing cortical thickness, although > 2 mm cortical layer no further increase in insertion torque was observed. In the models with only trabecular bone (without cortical layer) and with a 1 mm cortical layer, both implant types showed a statistically higher insertion and removal torque values for undersized compared with the press-fit technique. In addition, etched implants showed a statistically higher insertion and removal torque mean values compared with machined implants. In the models with 2 and 2.5 mm cortical layers, with respect to the insertion torque values, no effect of either implantation technique or implant surface topography could be observed. Conclusion The placement of etched implants in synthetic bone models using an undersized preparation technique resulted in enhanced primary implant stability. A correlation was found between the primary stability and the cortical thickness. However, at or above a cortical thickness of 2 mm, the effect of both an undersized surgical approach, as also the presence of a roughened (etched) implant surface, had no extra effect. Besides the mechanical aspects, the biological effect of undersized drilling, i.e. the bone response on the extra insertion torque forces should also be elucidated. Therefore, additional in vivo studies are needed. To cite this article:Tabassum A, Meijer GJ, Wolke JGC, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.Clin. Oral Impl. Res. 21, 2010; 213-220.doi: 10.1111/j.1600-0501.2009.01823.x.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 55 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model
    Al-Nawas, B.
    Groetz, K. A.
    Goetz, H.
    Duschner, H.
    Wagner, W.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (01) : 1 - 8
  • [3] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [4] Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection
    Alsaadi, Ghada
    Quirynen, Marc
    Komarek, Arnost
    van Steenberghe, Daniel
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (07) : 610 - 617
  • [5] A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment
    Alsaadi, Ghada
    Quirynen, Marc
    Michiels, Katleen
    Jacobs, Reinhilde
    van Steenberghe, Daniel
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) : 359 - 366
  • [6] Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
  • [7] Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible
    Beer, A
    Gahleitner, A
    Holm, A
    Tschabitscher, M
    Homolka, P
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (05) : 616 - 620
  • [8] Adapted preparation technique for screw-type implants:: explorative in vitro pilot study in a porcine bone model
    Beer, Andreas
    Gahleitner, Andre
    Holm, Anders
    Birkfellner, Wolfgang
    Homolka, Peter
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (01) : 103 - 107
  • [9] Physical characterization of different-roughness titanium surfaces, with and without hydroxyapatite coating, and their effect on human osteoblast-like cells
    Borsari, V
    Giavaresi, G
    Fini, M
    Torricelli, P
    Salito, A
    Chiesa, R
    Chiusoli, L
    Volpert, A
    Rimondini, L
    Giardino, R
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) : 359 - 368
  • [10] Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1