Inorganic arsenic speciation in water and seawater by anodic stripping voltammetry with a gold microelectrode

被引:160
作者
Salaun, Pascal
Planer-Friedrich, Britta
van den Berg, Constant M. G. [1 ]
机构
[1] Univ Liverpool, Dept Earth & Ocean Sci, Liverpool L69 3GP, Merseyside, England
[2] Tech Univ Bergakad Freiberg, Dept Geol, D-09599 Freiberg, Germany
关键词
arsenic; speciation; seawater; anodic stripping voltammetry; microelectrode; microwire electrode;
D O I
10.1016/j.aca.2006.12.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of arsenic in sea and freshwater by anodic stripping voltammetry (ASV) was revisited because of problems related to unstable peaks and inconveniently strong acidic conditions used by existing methods. Contrary to previous work it was found, that As(III) can be determined by ASV using a gold microwire electrode at any pH including the neutral pH typical for natural waters. As(V) on the other hand, requires acidification to pH 1, but this is still a much milder condition than used previously. This is the basis of a new method for the chemical speciation of arsenic in natural waters. The limits of detection are 0.2 nM As(III) at pH 8 and 0.3 nM combined arsenic (III + V) at pH 1 with a 30 s deposition time. These limits are lowered by extending the deposition time. The detection step at pH 8 was stripping chronopotentiometry (SC) as this was found to give a lower detection limit than ASV. Copper is co-determined simultaneously with arsenic. The method was applied successfully to the determination of arsenic as well as copper in samples from the Irish Sea, mineral water and tap water. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:312 / 322
页数:11
相关论文
共 59 条
[1]   High resolution monitoring of dissolved Cu and Co in coastal surface waters of the Western North Sea [J].
Achterberg, EP ;
van den Berg, CMG ;
Colombo, C .
CONTINENTAL SHELF RESEARCH, 2003, 23 (06) :611-623
[2]  
Adeloju SB, 1997, ANAL LETT, V30, P147, DOI 10.1080/00032719708002297
[3]   Constant current cathodic stripping potentiometric determination of arsenic on a mercury film electrode in the presence of copper ions [J].
Adeloju, SB ;
Young, TM ;
Jagner, D ;
Batley, GE .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :207-213
[4]   Flow injection method for the determination of arsenic(III) at trace levels in alkaline media [J].
Aldstadt, JH ;
Martin, AF .
ANALYST, 1996, 121 (10) :1387-1391
[5]   ARSENIC SPECIATION IN SEAWATER AND INTERSTITIAL WATERS - INFLUENCE OF BIOLOGICAL-CHEMICAL INTERACTIONS ON THE CHEMISTRY OF A TRACE-ELEMENT [J].
ANDREAE, MO .
LIMNOLOGY AND OCEANOGRAPHY, 1979, 24 (03) :440-452
[6]  
Barra CM, 2001, ELECTROANAL, V13, P1098, DOI 10.1002/1521-4109(200109)13:13<1098::AID-ELAN1098>3.0.CO
[7]  
2-I
[8]   TRACE DETERMINATION OF AS(III) AND AS(V) IN NATURAL-WATERS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
BODEWIG, FG ;
VALENTA, P ;
NURNBERG, HW .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 311 (03) :187-191
[9]   Arsenic at very low concentrations alters glucocorticoid receptor (GR)-mediated gene activation but not GR-mediated gene repression: Complex dose-response effects are closely correlated with levels of activated GR and require a functional GR DNA binding domain [J].
Bodwell, JE ;
Kingsley, LA ;
Hamilton, JW .
CHEMICAL RESEARCH IN TOXICOLOGY, 2004, 17 (08) :1064-1076
[10]   Determination of sub-μg 1-1 concentrations of copper by anodic stripping voltammetry at the gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 1999, 387 (01) :85-95