MR imaging of soft tissues adjacent to orthopaedic hardware: Techniques to minimize susceptibility artefact

被引:44
作者
Eustace, S
Goldberg, R
Williamson, D
Melhem, ER
Oladipo, O
Yucel, EK
Jara, H
机构
[1] BOSTON MED CTR,DEPT RADIOL,BOSTON,MA
[2] BOSTON MED CTR,DEPT ORTHOPED,BOSTON,MA
关键词
D O I
10.1016/S0009-9260(97)80250-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article demonstrates and compares imaging of orthopaedic hardware (fixation plates, screws, Kischner wire and prostheses) using gradient-echo, spin-echo and fast spin-echo sequences, It describes simple techniques which minimize susceptibility artefact induced by these components at magnetic resonance (MR) imaging, allowing visualization of adjacent soft tissues, The article emphasizes the importance of selecting the appropriate imaging plane in order to avoid hardware distortion of slice select gradients, emphasizes the importance of selecting frequency encoding gradient axes in order to orientate the long axis of the artefact away from the tissue of interest and, finally, compares the marked susceptibility artefact observed adjacent to hardware using gradient-echo with the artefact reduction achieved by using fast spin-echo sequences.
引用
收藏
页码:589 / 594
页数:6
相关论文
共 9 条
  • [1] SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING
    CONSTABLE, RT
    SMITH, RC
    GORE, JC
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) : 41 - 47
  • [2] CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P1149
  • [3] EFFECT OF FIELD-STRENGTH ON SUSCEPTIBILITY ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    FARAHANI, K
    SINHA, U
    SINHA, S
    CHIU, LCL
    LUFKIN, RB
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (06) : 409 - 413
  • [4] RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR
    HENNIG, J
    NAUERTH, A
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 823 - 833
  • [5] MR IMAGING IN PATIENTS WITH METALLIC IMPLANTS
    LAAKMAN, RW
    KAUFMAN, B
    HAN, JS
    NELSON, AD
    CLAMPITT, M
    OBLOCK, AM
    HAAGA, JR
    ALFIDI, RJ
    [J]. RADIOLOGY, 1985, 157 (03) : 711 - 714
  • [6] CONTRAST MANIPULATION AND ARTIFACT ASSESSMENT OF 2D AND 3D RARE SEQUENCES
    MULKERN, RV
    WONG, STS
    WINALSKI, C
    JOLESZ, FA
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (05) : 557 - 566
  • [7] Optimizing imaging parameters for MR evaluation of the spine with titanium pedicle screws
    Petersilge, CA
    Lewin, JS
    Duerk, JL
    Yoo, JU
    Ghaneyem, AJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1213 - 1218
  • [8] SKINNER HB, 1993, OPERATIVE ORTHOPEDIC, P167
  • [9] METALLIC ARTIFACTS ON MR-IMAGES OF THE POSTOPERATIVE SPINE - REDUCTION WITH FAST SPIN-ECHO TECHNIQUES
    TARTAGLINO, LM
    FLANDERS, AE
    VINITSKI, S
    FRIEDMAN, DP
    [J]. RADIOLOGY, 1994, 190 (02) : 565 - 569