Comparison of enzyme immobilisation methods for potentiometric phosphate biosensors

被引:13
|
作者
Lawal, A. T. [1 ]
Adeloju, S. B. [1 ]
机构
[1] Monash Univ, NanoSci & Sensor Technol Res Grp, Sch Engn & Appl Sci, Churchill, Vic 3842, Australia
关键词
Immobilisation methods; Polypyrrole; Potentiometric detection; Phosphate; Biosensor; FLOW-INJECTION SYSTEM; GUIDE CAPILLARY CELL; PYRUVATE OXIDASE; AMPEROMETRIC DETERMINATION; ALKALINE-PHOSPHATASE; SPECTROPHOTOMETRIC DETERMINATION; NANOMOLAR CONCENTRATIONS; IMPROVED SENSITIVITY; INORGANIC-PHOSPHATE; FIA BIOSENSOR;
D O I
10.1016/j.bios.2009.07.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of two phosphate biosensors is described and compared for potentiometric detection of phosphate. Purine nucleoside phosphorylase (PNP) and xanthine oxidase (XOD) were co-immobilised by chemical cross-linking with glutaraldehyde (GLA) and bovine serum albumin (BSA), and via entrapment into polypyrrole (PPy) films by galvanostatic polymerisation. The BSA-GLA film was made with 4.5% v/v GLA and 6.8% w/v BSA with a drying time of 30 min, while polypyrrole entrapment was achieved with 0.5 M pyrrole by using a polymerisation time of 200 s. A mote ratio of 1:8 (6.2 U/mL XOD: 49.6 U/mL PNP) was used for both methods of enzyme immobilisation. Sensitive potentiometric measurements obtained for phosphate with the BSA-GLA-PNP-XOD biosensor were compared with those of PPy-PNP-XOD-Fe(CN)(6)(4-) biosensor. A minimum detectable concentration of 0.1 mg/L phosphate and a linear concentration range of 0.5-2.5 mg/L were achieved with the PPy-PNP-XOD-Fe(CN)(6)(4-) biosensor. In comparison, a minimum detectable concentration of 2 mg/L and a linear concentration range of 4-12 mg/L were achieved with the BSA-GLA immobilisation. The presence of uric and ascorbic acids had the least effect on the performance of the PPy-PNP-XOD-Fe(CN)(6)(4-) biosensor, but will not have any effect on phosphate measurement with both biosensors at levels normally present in water. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:406 / 410
页数:5
相关论文
共 50 条
  • [11] Recent advances in potentiometric biosensors
    Ding, Jiawang
    Qin, Wei
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 124
  • [12] Immobilisation of actinides in phosphate matrices
    Dacheux, N
    Clavier, N
    Robisson, AC
    Terra, O
    Audubert, F
    Lartigue, JÉ
    Guy, C
    COMPTES RENDUS CHIMIE, 2004, 7 (12) : 1141 - 1152
  • [13] Enzyme Immobilization by Inkjet Printing on Reagentless Biosensors for Electrochemical Phosphate Detection
    Zhang, Dongxing
    Bai, Yang
    Niu, Haoran
    Chen, Lingyun
    Xiao, Junfeng
    Guo, Qiuquan
    Jia, Peipei
    BIOSENSORS-BASEL, 2024, 14 (04):
  • [14] Comparison of Various Phosphate Stabilisation Agents for the Immobilisation of Ni and Zn in Sewage Sludge
    Marija Zupančič
    Nataša Bukovec
    Radmila Milačič
    Janez Ščančar
    Water, Air, and Soil Pollution, 2004, 156 : 57 - 69
  • [15] Comparison of various phosphate stabilisation agents for the immobilisation of Ni and Zn in sewage sludge
    Zupancic, M
    Bukovec, N
    Milacic, R
    Scancar, J
    WATER AIR AND SOIL POLLUTION, 2004, 156 (1-4) : 57 - 69
  • [16] Polypyrrole-based bilayer biosensor for potentiometric determination of phosphate in natural waters
    Adeloju, SB
    Lawal, A
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2005, 85 (9-11) : 771 - 780
  • [17] Potentiometric biosensors based on polyaniline semiconductor films
    Karyakin, AA
    Bobrova, OA
    Luckachova, LV
    Karyakina, EE
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) : 34 - 38
  • [18] Potentiometric biosensors based on silicon and porous silicon
    Basu, I
    Subramanian, RV
    Mathew, A
    Chadha, A
    Bhattacharya, E
    NSTI NANOTECH 2004, VOL 1, TECHNICAL PROCEEDINGS, 2004, : 224 - 227
  • [19] Computational Modelling of the Behaviour of Potentiometric Membrane Biosensors
    R. Baronas
    F. Ivanauskas
    J. Kulys
    Journal of Mathematical Chemistry, 2007, 42 : 321 - 336
  • [20] Computational modelling of the behaviour of potentiometric membrane biosensors
    Baronas, R.
    Ivanauskas, F.
    Kulys, J.
    JOURNAL OF MATHEMATICAL CHEMISTRY, 2007, 42 (03) : 321 - 336