Comparison of enzyme immobilisation methods for potentiometric phosphate biosensors

被引:13
|
作者
Lawal, A. T. [1 ]
Adeloju, S. B. [1 ]
机构
[1] Monash Univ, NanoSci & Sensor Technol Res Grp, Sch Engn & Appl Sci, Churchill, Vic 3842, Australia
关键词
Immobilisation methods; Polypyrrole; Potentiometric detection; Phosphate; Biosensor; FLOW-INJECTION SYSTEM; GUIDE CAPILLARY CELL; PYRUVATE OXIDASE; AMPEROMETRIC DETERMINATION; ALKALINE-PHOSPHATASE; SPECTROPHOTOMETRIC DETERMINATION; NANOMOLAR CONCENTRATIONS; IMPROVED SENSITIVITY; INORGANIC-PHOSPHATE; FIA BIOSENSOR;
D O I
10.1016/j.bios.2009.07.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of two phosphate biosensors is described and compared for potentiometric detection of phosphate. Purine nucleoside phosphorylase (PNP) and xanthine oxidase (XOD) were co-immobilised by chemical cross-linking with glutaraldehyde (GLA) and bovine serum albumin (BSA), and via entrapment into polypyrrole (PPy) films by galvanostatic polymerisation. The BSA-GLA film was made with 4.5% v/v GLA and 6.8% w/v BSA with a drying time of 30 min, while polypyrrole entrapment was achieved with 0.5 M pyrrole by using a polymerisation time of 200 s. A mote ratio of 1:8 (6.2 U/mL XOD: 49.6 U/mL PNP) was used for both methods of enzyme immobilisation. Sensitive potentiometric measurements obtained for phosphate with the BSA-GLA-PNP-XOD biosensor were compared with those of PPy-PNP-XOD-Fe(CN)(6)(4-) biosensor. A minimum detectable concentration of 0.1 mg/L phosphate and a linear concentration range of 0.5-2.5 mg/L were achieved with the PPy-PNP-XOD-Fe(CN)(6)(4-) biosensor. In comparison, a minimum detectable concentration of 2 mg/L and a linear concentration range of 4-12 mg/L were achieved with the BSA-GLA immobilisation. The presence of uric and ascorbic acids had the least effect on the performance of the PPy-PNP-XOD-Fe(CN)(6)(4-) biosensor, but will not have any effect on phosphate measurement with both biosensors at levels normally present in water. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:406 / 410
页数:5
相关论文
共 50 条
  • [1] Polypyrrole based amperometric and potentiometric phosphate biosensors: A comparative study B
    Lawal, Abdulazeez T.
    Adeloju, Samuel B.
    BIOSENSORS & BIOELECTRONICS, 2013, 40 (01) : 377 - 384
  • [2] Polypyrrole based amperometric and potentiometric phosphate biosensors: A comparative study
    Lawal, Abdulazeez T.
    Adeloju, Samuel B.
    Journal of Applied Sciences, 2012, 12 (04) : 315 - 325
  • [3] Polypyrrole-based potentiometric phosphate biosensor
    Lawal, A. T.
    Adeloju, S. B.
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2010, 63 (1-2) : 45 - 49
  • [4] Recent advances in phosphate biosensors
    Upadhyay, Lata Sheo Bachan
    Verma, Nishant
    BIOTECHNOLOGY LETTERS, 2015, 37 (07) : 1335 - 1345
  • [5] Fabrication of a bilayer potentiometric phosphate biosensor by cross-link immobilization with bovine serum albumin and glutaraldehyde
    Adeloju, Samuel B.
    Lawal, Abdulazeez T.
    ANALYTICA CHIMICA ACTA, 2011, 691 (1-2) : 89 - 94
  • [6] Immobilisation of enzyme throughout a polytyramine matrix: a versatile procedure for fabricating biosensors
    Situmorang, M
    Gooding, JJ
    Hibbert, DB
    ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) : 211 - 223
  • [7] A critical perspective on the applied potential in amperometric phosphate biosensors
    Uru, Seyda Korkut
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 58
  • [8] Potentiometric urea biosensors
    Ozbek, Oguz
    Berkel, Caglar
    Isildak, Omer
    Isildak, Ibrahim
    CLINICA CHIMICA ACTA, 2022, 524 : 154 - 163
  • [9] Studies on the construction and operation of miniaturized potentiometric biosensors
    Konopinska, Kamila
    Pietrzak, Mariusz
    Malinowska, Elzbieta
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (06) : 1665 - 1675
  • [10] Studies on the construction and operation of miniaturized potentiometric biosensors
    Kamila Konopińska
    Mariusz Pietrzak
    Elżbieta Malinowska
    Journal of Solid State Electrochemistry, 2013, 17 : 1665 - 1675