Agreement in component size between preoperative measurement, navigation and final implant in total knee replacement

被引:4
作者
Hernandez-Vaquero, Daniel [1 ]
Noriega-Fernandez, Alfonso [2 ]
Roncero-Gonzalez, Sergio [2 ]
Perez-Coto, Ivan [2 ]
Sierra-Pereira, Andres A. [2 ]
Sandoval-Garcia, Manuel A. [2 ]
机构
[1] Univ Oviedo, Dept Orthopaed, Sch Med, Asturias, Spain
[2] St Agustin Univ Hosp, Dept Orthopaed, Aviles, Spain
关键词
Component size; Digital templating; Navigation; Total knee replacement; ANTERIOR FEMORAL CORTEX; TIBIAL COMPONENT; TOTAL HIP; ARTHROPLASTY; RISK; RELIABILITY; OVERHANG; INSTRUMENTATION; METAANALYSIS; ALIGNMENT;
D O I
10.1016/j.jot.2018.10.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: One of the possible causes of dissatisfaction reported by many patients after total knee replacement (TKR) is the lack of agreement between component size and bone structure. To avoid this complication and facilitate the procedure, preoperative planning with digitized templates is recommended. Surgical navigation indicates the best position and the most adequate size of arthroplasty and may therefore replace preoperative radiographic measurement. The objective of the study was to check agreement between the sizes of TKR components measured before surgery with digitized templates, the size recommended by the navigation and sizes actually implanted. Methods: In 103 patients scheduled for TKR, preoperative full-limb radiography was performed to measure the mechanical and anatomical axes of the limb, femur and tibia. The most adequate size of the femoral and tibial components was planned by superimposing digitized templates. The size recommended in navigation and the size of the finally implanted components were also recorded. Results: A high level of agreement was found between the sizes of femoral and tibial components measured by X-rays and in navigation (0.750 and 0.772, respectively) (intraclass correlation and Cronbach's alpha). Agreement between the sizes recommended by X-rays and navigation and those finally implanted was 0.886 for the femur and 0.891 for the tibia. Agreement levels were not different in cases with prior deformities of limb axis. Conclusions: The high level of agreement found in component sizes between radiographic measurement with digitized templates and navigation suggests that preoperative X-ray measurement is not needed when navigation is used for placement of implants during TKR. (C) 2018 The Authors. Published by Elsevier (Singapore) Pte Ltd on behalf of Chinese Speaking Orthopaedic Society.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 39 条
  • [1] Aslam Nadim, 2004, Acta Orthop Belg, V70, P560
  • [2] Barrett WP, 2006, ORTHOPEDICS, V29, pS53
  • [3] Determining Femoral Component Position Using CAS and Measured Resection
    Benjamin, James
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) : 2745 - 2750
  • [4] Oversizing the tibial component in TKAs: incidence, consequences and risk factors
    Bonnin, Michel P.
    Saffarini, Mo
    Shepherd, David
    Bossard, Nadine
    Dantony, Emmanuelle
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2532 - 2540
  • [5] Mediolateral oversizing influences pain, function, and flexion after TKA
    Bonnin, Michel P.
    Schmidt, Axel
    Basiglini, Luca
    Bossard, Nadine
    Dantony, Emmanuelle
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2314 - 2324
  • [6] Patient Satisfaction after Total Knee Arthroplasty Who is Satisfied and Who is Not?
    Bourne, Robert B.
    Chesworth, Bert M.
    Davis, Aileen M.
    Mahomed, Nizar N.
    Charron, Kory D. J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 57 - 63
  • [7] Knee replacement
    Carr, Andrew J.
    Robertsson, Otto
    Graves, Stephen
    Price, Andrew J.
    Arden, Nigel K.
    Judge, Andrew
    Beard, David J.
    [J]. LANCET, 2012, 379 (9823) : 1331 - 1340
  • [8] Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    Haaker, RG
    Stockheim, M
    Kamp, M
    Proff, G
    Breitenfelder, J
    Ottersbach, A
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) : 152 - 159
  • [9] Hernandez-Vaquero D, 2017, Rev Esp Cir Ortop Traumatol, V61, P313, DOI 10.1016/j.recot.2017.03.007
  • [10] Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty
    Hernandez-Vaquero, Daniel
    Abat, Ferran
    Sarasquete, Juan
    Carlos Monllau, Juan
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2013, 4 (04): : 287 - 290