The reliability and concurrent validity of the figure-of-eight method of measuring hand edema in patients with burns

被引:18
|
作者
Dewey, William S. [1 ]
Hedman, Travis L. [1 ]
Chapman, Ted T. [1 ]
Wolf, Steven E. [1 ]
Holcomb, John B. [1 ]
机构
[1] USA, Inst Surg Res, Burn Ctr, Ft Sam Houston, TX 78234 USA
来源
JOURNAL OF BURN CARE & RESEARCH | 2007年 / 28卷 / 01期
关键词
D O I
10.1097/BCR.0b013e31802c9eb9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Water volumetry is considered the "gold standard" for hand edema assessment. This technique requires considerable time, staff, and specialized equipment. The figure-of-eight method for hand edema assessment has been tested only in the orthopedic population. The objective of this study was to test the reliability. and concurrent validity of the figure-of-eight method of measuring hand edema in the burn patient population. Methods: We conducted a prospective blinded study with 20 burned patients (33 edematous hands) admitted from February to May 2005. Two testers performed three separate blinded measurements on each edematous hand, using the figure-of-eight technique. A third tester performed two measurements, using water volumetry. An independent investigator recorded all measurements. Intratester and intertester reliability were analyzed. Concurrent validity was examined and compared with water volumetry measurements. Results: Intraclass correlation coefficients (ICC) for the intratester reliability of the figure-of-eight method were 0.96 for tester 1 and 0.97 for tester 2. The ICC for intertester reliability of the figure-of-eight measurements was 0.94. The intratester ICC for volumetric measurements was 0.99. Correlation coefficient (Pearson's) for tester 1 was 0.83 (P < .01), and for tester 2, 0.89 (P < .01). Conclusion: The figure-of-eight technique is a reliable and valid measurement tool for measuring hand edema. This technique is a more clinically feasible tool than water volumetry in the burn patient population.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [21] Validity and reliability of the block method for measuring thoracic hyperkyphosis
    Chokphukiao, Pakwipa
    Wiyanad, Arpassanan
    Suwannarat, Patcharawan
    Amatachaya, Sugalya
    Mato, Lugkana
    Wattanapan, Pattra
    Gaogasigam, Chitanongk
    Thaweewannakij, Thiwabhorn
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (13) : 3037 - 3044
  • [22] Reliability And Validity Of A Method For Measuring Dynamic Muscular Effort
    Gregory, Robert
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S320 - S320
  • [23] Reliability of water volumetry and the figure of eight method on subjects with ankle joint swelling
    Petersen, EJ
    Irish, SM
    Lyons, CL
    Miklaski, SF
    Bryan, JM
    Henderson, NE
    Masullo, LN
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1999, 29 (10): : 609 - 615
  • [24] Concurrent Validity and Reliability of a Handheld Dynamometer in Measuring Isometric Shoulder Rotational Strength
    Chen, Bin
    Liu, Lifen
    Chen, Lincoln Bin
    Cao, Xianxin
    Han, Peng
    Wang, Chenhao
    Qi, Qi
    JOURNAL OF SPORT REHABILITATION, 2021, 30 (06) : 965 - 968
  • [25] Comparison of figure-of-eight and simple wire sternal closure techniques in patients with non-microbial sternal dehiscence
    Tekumit, Hayrettin
    Cenal, Ali Riza
    Tataroglu, Cenk
    Uzun, Kemal
    Akinci, Esat
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2009, 9 (05): : 411 - 416
  • [26] CONCURRENT VALIDITY OF HAND-HELD SPHYGMOMANOMETER DYNAMOMETRY FOR MEASURING THIGH MUSCLE STRENGTHS
    Wood, Laurence R.
    Hay, Elaine M.
    Sim, Julius
    RHEUMATOLOGY, 2009, 48 : I159 - I159
  • [27] Response to the Letter to the Editor "Selection of Appropriate Patients for Figure-of-Eight Suturing During Removal of Large Bore Transfemoral Sheaths"
    Kiani, Soroosh
    El-Chami, Mikhael F.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (10) : 2182 - 2182
  • [28] Reliability, Concurrent Validity, and Minimal Detectable Change of a Smartphone Application for Measuring Thoracic Kyphosis
    Sahinoglu, Ertan
    Ergin, Gulbin
    Bakirhan, Serkan
    Unver, Bayram
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2023, 13 (03): : 511 - 516
  • [29] Concurrent validity and intratester reliability of the video-based system for measuring gait poststroke
    Aung, Nilar
    Bovonsunthonchai, Sunee
    Hiengkaew, Vimonwan
    Tretriluxana, Jarugool
    Rojasavastera, Rom Manee
    Pheung-Phrarattanatrai, Anuchai
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2020, 25 (01)
  • [30] The Validity and Reliability of Navicular Angle Method in Measuring Foot Arch
    Yuan, Zhang J.
    Lin, Hui-Mei
    Tseng, Yu-Hua
    Fu, Szu-Kai
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 53 - 53