The reliability and concurrent validity of the figure-of-eight method of measuring hand edema in patients with burns

被引:18
|
作者
Dewey, William S. [1 ]
Hedman, Travis L. [1 ]
Chapman, Ted T. [1 ]
Wolf, Steven E. [1 ]
Holcomb, John B. [1 ]
机构
[1] USA, Inst Surg Res, Burn Ctr, Ft Sam Houston, TX 78234 USA
来源
JOURNAL OF BURN CARE & RESEARCH | 2007年 / 28卷 / 01期
关键词
D O I
10.1097/BCR.0b013e31802c9eb9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Water volumetry is considered the "gold standard" for hand edema assessment. This technique requires considerable time, staff, and specialized equipment. The figure-of-eight method for hand edema assessment has been tested only in the orthopedic population. The objective of this study was to test the reliability. and concurrent validity of the figure-of-eight method of measuring hand edema in the burn patient population. Methods: We conducted a prospective blinded study with 20 burned patients (33 edematous hands) admitted from February to May 2005. Two testers performed three separate blinded measurements on each edematous hand, using the figure-of-eight technique. A third tester performed two measurements, using water volumetry. An independent investigator recorded all measurements. Intratester and intertester reliability were analyzed. Concurrent validity was examined and compared with water volumetry measurements. Results: Intraclass correlation coefficients (ICC) for the intratester reliability of the figure-of-eight method were 0.96 for tester 1 and 0.97 for tester 2. The ICC for intertester reliability of the figure-of-eight measurements was 0.94. The intratester ICC for volumetric measurements was 0.99. Correlation coefficient (Pearson's) for tester 1 was 0.83 (P < .01), and for tester 2, 0.89 (P < .01). Conclusion: The figure-of-eight technique is a reliable and valid measurement tool for measuring hand edema. This technique is a more clinically feasible tool than water volumetry in the burn patient population.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [1] Reliability and concurrent validity of the figure-of-eight method of measuring hand size in patients with hand pathology
    Leard, JS
    Breglio, L
    Fraga, L
    Ellrod, N
    Nadler, L
    Yasso, M
    Fay, E
    Ryan, K
    Pellecchia, GL
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2004, 34 (06): : 335 - 340
  • [2] Reliability and validity of the figure-of-eight method of measuring hand size in patients with breast cancer-related lymphoedema
    Borthwick, Y.
    Paul, L.
    Sneddon, M.
    McAlpine, L.
    Miller, C.
    EUROPEAN JOURNAL OF CANCER CARE, 2013, 22 (02) : 196 - 201
  • [3] Criterion-related validity of the figure-of-eight method of measuring ankle edema
    Mawdsley, RH
    Hoy, DK
    Erwin, PM
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2000, 30 (03): : 149 - 153
  • [4] Reliability, Validity, and Feasibility of Water Displacement Method, Figure-of-Eight Method, and Circumference Measurements in Determination of Ankle and Foot Edema
    Devoogdt, Nele
    Cavaggion, Claudia
    Van der Gucht, Elien
    Dams, Lore
    De Groef, An
    Meeus, Mira
    Van Hemelrijck, Roxane
    Heynen, Anneleen
    Thomis, Sarah
    Orhan, Ceren
    LYMPHATIC RESEARCH AND BIOLOGY, 2019, 17 (05) : 531 - 536
  • [5] Reliability of Occupational Therapy Students Using the Figure-of-eight Technique of Measuring Hand Volume
    Nadar, Mohammad Shaban
    Al-Kandari, Dua'a
    Taaqi, Maqdad
    HONG KONG JOURNAL OF OCCUPATIONAL THERAPY, 2013, 23 (01) : 20 - 25
  • [6] Reliability of Jeweler Rings and a Revised Figure-of-Eight Circumference Protocol for the Assessment of Finger and Hand Circumferences
    Gebruers, Nick
    Van Soom, Timia
    Verbelen, Hanne
    De Vrieze, Tessa
    LYMPHATIC RESEARCH AND BIOLOGY, 2021, 19 (06) : 580 - 584
  • [7] Digital assessment of walking ability: Validity and reliability of the automated figure-of-eight walk test in older adults
    Kong, Hyun-Ho
    Shin, Kwangsoo
    Yang, Dong-Seok
    Gu, Hye-Young
    Joo, Hyeon-Seong
    Shon, Hyun-Chul
    PLOS ONE, 2025, 20 (02):
  • [8] RESPONSIVENESS OF THE FIGURE-OF-EIGHT TAPE MEASUREMENT TO DETECT HAND SIZE CHANGES OF PATIENTS WITH ACUTE AND CHRONIC HAND PATHOLOGIES
    Leard, John S.
    Crane, Barbara A.
    Mayette, Darci L.
    Maritzer, Ashley K.
    Libman, Dmitry
    Silva, Bryan C.
    Failla, Mat J.
    HAND THERAPY, 2008, 13 (03) : 84 - 90
  • [9] Reliability and Concurrent Validity of the Ring Gauge Method and the Metacarpal Head Tape Measure Method of Measuring Hand Size
    Yamazaki, Hiroshi
    Sakurai, Toshiysasu
    Uchiyama, Shigeharu
    Kato, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2018, 23 (03): : 382 - 387
  • [10] Reliability and Concurrent Validity of the Perometer for Measuring Hand Volume in Women With and Without Lymphedema
    Lee, Mi-Joung
    Boland, Robert A.
    Czerniec, Sharon
    Kilbreath, Sharon L.
    LYMPHATIC RESEARCH AND BIOLOGY, 2011, 9 (01) : 13 - 18