The reliability and concurrent validity of the figure-of-eight method of measuring hand edema in patients with burns

被引:18
作者
Dewey, William S. [1 ]
Hedman, Travis L. [1 ]
Chapman, Ted T. [1 ]
Wolf, Steven E. [1 ]
Holcomb, John B. [1 ]
机构
[1] USA, Inst Surg Res, Burn Ctr, Ft Sam Houston, TX 78234 USA
关键词
D O I
10.1097/BCR.0b013e31802c9eb9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Water volumetry is considered the "gold standard" for hand edema assessment. This technique requires considerable time, staff, and specialized equipment. The figure-of-eight method for hand edema assessment has been tested only in the orthopedic population. The objective of this study was to test the reliability. and concurrent validity of the figure-of-eight method of measuring hand edema in the burn patient population. Methods: We conducted a prospective blinded study with 20 burned patients (33 edematous hands) admitted from February to May 2005. Two testers performed three separate blinded measurements on each edematous hand, using the figure-of-eight technique. A third tester performed two measurements, using water volumetry. An independent investigator recorded all measurements. Intratester and intertester reliability were analyzed. Concurrent validity was examined and compared with water volumetry measurements. Results: Intraclass correlation coefficients (ICC) for the intratester reliability of the figure-of-eight method were 0.96 for tester 1 and 0.97 for tester 2. The ICC for intertester reliability of the figure-of-eight measurements was 0.94. The intratester ICC for volumetric measurements was 0.99. Correlation coefficient (Pearson's) for tester 1 was 0.83 (P < .01), and for tester 2, 0.89 (P < .01). Conclusion: The figure-of-eight technique is a reliable and valid measurement tool for measuring hand edema. This technique is a more clinically feasible tool than water volumetry in the burn patient population.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 13 条
  • [1] [Anonymous], 1991, J Hand Ther
  • [2] DEVORE GL, 1968, AM J OCCUP THER, V22, P16
  • [3] THE NEED FOR RELIABILITY AND VALIDITY IN HAND ASSESSMENT INSTRUMENTS
    FESS, EE
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1986, 11A (05): : 621 - 623
  • [4] King T I 2nd, 1993, J Hand Ther, V6, P202
  • [5] Reliability and concurrent validity of the figure-of-eight method of measuring hand size in patients with hand pathology
    Leard, JS
    Breglio, L
    Fraga, L
    Ellrod, N
    Nadler, L
    Yasso, M
    Fay, E
    Ryan, K
    Pellecchia, GL
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2004, 34 (06) : 335 - 340
  • [6] Maihafer George C, 2003, J Hand Ther, V16, P305, DOI 10.1197/S0894-1130(03)00155-8
  • [7] MOBERG E, 1960, SURG CLIN N AM, V40, P367
  • [8] Munro B.H., 2000, STAT METHODS HLTH CA, P235
  • [9] Pellecchia Geraldine L, 2003, J Hand Ther, V16, P300, DOI 10.1197/S0894-1130(03)00154-6
  • [10] PORTNEY LG, 1993, FDN CLIN RES APPL PR, P58