Loop-mediated isothermal amplification targeting the apxIVA gene for detection of Actinobacillus pleuropneumoniae

被引:20
作者
Yang, Wang [1 ]
Pin, Chen [1 ]
Haibing, Guo [1 ]
Yang, Chen [1 ]
Hui, Liu [1 ]
Qigai, He [1 ]
机构
[1] Huazhong Agr Univ, State Key Lab Agr Microbiol, Div Anim Infect Dis, Wuhan 430070, Hubei, Peoples R China
关键词
Actinobacillus pleuropneumoniae; loop-mediated isothermal amplification; nested PCR; detection; field trial; PCR ASSAY; NUCLEOTIDE-SEQUENCE; RAPID DIAGNOSIS; IDENTIFICATION; INFECTION; VIRUS; PIGS;
D O I
10.1111/j.1574-6968.2009.01779.x
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method performed under isothermal conditions with high specificity and efficiency. We developed a diagnostic method based on LAMP for detection of Actinobacillus pleuropneumoniae. Using six specific primers targeting the apxIVA gene, the LAMP assay rapidly amplified the target gene within 30 min, requiring only a laboratory water bath for the reaction to occur. The resulting amplificon was visualized by adding SYBR Green I to the mixture. The results obtained from testing 15 A. pleuropneumoniae reference strains and other seven bacterial species strains showed that the LAMP was as specific as and 10 times more sensitive than nested PCR. Sixty-five tonsil samples were collected from 65 healthy pigs. All the samples were negative for A. pleuropneumoniae by immunomagnetic separation-based (IMS) bacterial isolation, nested PCR and LAMP, respectively. Meanwhile, 115 tonsil samples were also collected from 115 pigs with apparent respiratory problems. Twenty-two were positive by IMS bacterial isolation. All the samples that were positive by IMS bacterial isolation were also positive by nested PCR and LAMP. The LAMP assay demonstrated exceptionally higher sensitivity than nested PCR by picking up 14 additional positive cases (chi 2 test, P < 0.0001); we concluded that LAMP was a highly sensitive and reliable method for detection of A. pleuropneumoniae infection.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 50 条
  • [41] Development of loop-mediated isothermal amplification assay for detection of human coronavirus-NL63
    Pyrc, Krzysztof
    Milewska, Aleksandra
    Potempa, Jan
    JOURNAL OF VIROLOGICAL METHODS, 2011, 175 (01) : 133 - 136
  • [42] Application of loop-mediated isothermal amplification for detection of Yersinia enterocolitica in pork meat
    Gao, Hongwei
    Lei, Zhiwen
    Jia, Juntao
    Wang, Shufeng
    Chen, Ying
    Sun, Min
    Liang, Chengzhu
    JOURNAL OF MICROBIOLOGICAL METHODS, 2009, 77 (02) : 198 - 201
  • [43] Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Hepatitis C virus
    Kargar, Mohammad
    Askari, Ahzam
    Doosti, Abbas
    Ghorbani-Dalini, Sadegh
    INDIAN JOURNAL OF VIROLOGY, 2012, 23 (01): : 18 - 23
  • [44] Detection of Actinobacillus pleuropneumoniae through Duplex PCR Based on ApxIA and ApxIVA Genes
    Lin, Huayuan
    Mao, Huirong
    Cheng, Sufang
    Yi, Mengying
    Ruan, Yezhao
    Wu, Cong
    Xu, Zheng
    Hu, Guoliang
    Guo, Xiaoquan
    Cao, Huabin
    Li, Lin
    Han, Yinhua
    Liu, Ping
    PAKISTAN VETERINARY JOURNAL, 2018, 38 (03) : 276 - 280
  • [45] Detection of fish nocardiosis by loop-mediated isothermal amplification
    Itano, T.
    Kawakami, H.
    Kono, T.
    Sakai, M.
    JOURNAL OF APPLIED MICROBIOLOGY, 2006, 100 (06) : 1381 - 1387
  • [46] Loop-mediated isothermal amplification for the rapid detection of Salmonella
    Hara-Kudo, Y
    Yoshino, M
    Kojima, T
    Ikedo, M
    FEMS MICROBIOLOGY LETTERS, 2005, 253 (01) : 155 - 161
  • [47] Study on Loop-mediated Isothermal Amplification Assay for Detection of Salmonella in Meat Products
    Wang Yu
    Zhang Wei
    Yuan Yaowu
    Ma Xiaoyan
    Zhang Huiyan
    Su Xudong
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1779 - 1784
  • [48] Detection of Botrytis cinerea by loop-mediated isothermal amplification
    Tomlinson, J. A.
    Dickinson, M. J.
    Boonham, N.
    LETTERS IN APPLIED MICROBIOLOGY, 2010, 51 (06) : 650 - 657
  • [49] Loop-mediated isothermal amplification for the detection of goose circovirus
    Grzegorz Woźniakowski
    Wojciech Kozdruń
    Elżbieta Samorek-Salamonowicz
    Virology Journal, 9
  • [50] Rapid detection of Actinobacillus pleuropneumoniae targeting the apxIVA gene for diagnosis of contagious porcine pleuropneumonia in pigs by polymerase spiral reaction
    Sarkar, R.
    Roychoudhury, P.
    Kumar, S.
    Dutta, S.
    Konwar, N.
    Subudhi, P. K.
    Dutta, T. K.
    LETTERS IN APPLIED MICROBIOLOGY, 2022, 75 (02) : 442 - 449