Optimizing the frame duration for data-driven rigid motion estimation in brain PET imaging

被引:10
|
作者
Spangler-Bickell, Matthew G. [1 ,2 ]
Hurley, Samuel A. [1 ]
Deller, Timothy W. [2 ]
Jansen, Floris [2 ]
Bettinardi, Valentino [3 ]
Carlson, Mackenzie [4 ]
Zeineh, Michael [4 ]
Zaharchuk, Greg [4 ]
McMillan, Alan B. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] GE Healthcare, PET MR Engn, Waukesha, WI 53188 USA
[3] Nucl Med Unit, IRCCS Osped San Raffaele, Milan, Italy
[4] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
brain imaging; data-driven motion estimation; list-mode; PET reconstruction; rigid motion correction; ultrashort frames; HEAD MOTION; REGISTRATION; RECONSTRUCTION; PERFORMANCE; IMAGES;
D O I
10.1002/mp.14889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Data-driven rigid motion estimation for PET brain imaging is usually performed using data frames sampled at low temporal resolution to reduce the overall computation time and to provide adequate signal-to-noise ratio in the frames. In recent work it has been demonstrated that list-mode reconstructions of ultrashort frames are sufficient for motion estimation and can be performed very quickly. In this work we take the approach of using image-based registration of reconstructions of very short frames for data-driven motion estimation, and optimize a number of reconstruction and registration parameters (frame duration, MLEM iterations, image pixel size, post-smoothing filter, reference image creation, and registration metric) to ensure accurate registrations while maximizing temporal resolution and minimizing total computation time. Methods: Data from F-18-fluorodeoxyglucose (FDG) and F-18-florbetaben (FBB) tracer studies with varying count rates are analyzed, for PET/MR and PET/CT scanners. For framed reconstructions using various parameter combinations interframe motion is simulated and image-based registrations are performed to estimate that motion. Results: For FDG and FBB tracers using 4 x 10(5) true and scattered coincidence events per frame ensures that 95% of the registrations will be accurate to within 1 mm of the ground truth. This corresponds to a frame duration of 0.5-1 sec for typical clinical PET activity levels. Using four MLEM iterations with no subsets, a transaxial pixel size of 4 mm, a post-smoothing filter with 4-6 mm full width at half maximum, and averaging two or more frames to create the reference image provides an optimal set of parameters to produce accurate registrations while keeping the reconstruction and processing time low. Conclusions: It is shown that very short frames (<= 1 sec) can be used to provide accurate and quick data-driven rigid motion estimates for use in an event-by-event motion corrected reconstruction. (C) 2021 American Association of Physicists in Medicine
引用
收藏
页码:3031 / 3041
页数:11
相关论文
共 50 条
  • [21] Fast dynamic brain PET imaging using stochastic variational prediction for recurrent frame generation
    Sanaat, Amirhossein
    Mirsadeghi, Ehsan
    Razeghi, Behrooz
    Ginovart, Nathalie
    Zaidi, Habib
    MEDICAL PHYSICS, 2021, 48 (09) : 5059 - 5071
  • [22] Impact of acquisition time and misregistration with CT on data-driven gated PET
    Thomas, M. Allan
    Meier, Joseph G.
    Mawlawi, Osama R.
    Sun, Peng
    Pan, Tinsu
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (08)
  • [23] Marker-less Multi-frame Motion Tracking and Compensation in PET-Brain Imaging
    Lindsay, C.
    Mukherjee, J. M.
    Johnson, K.
    Olivier, P.
    Song, X.
    Shao, L.
    King, M. A.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [24] Data-driven estimation of expected photovoltaic generation
    Amaro e Silva, R.
    Monteiro Baptista, J.
    Brito, M. C.
    SOLAR ENERGY, 2018, 166 : 116 - 122
  • [25] Retrospective data-driven respiratory gating for PET/CT
    Schleyer, Paul J.
    O'Doherty, Michael J.
    Barrington, Sally F.
    Marsden, Paul K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) : 1935 - 1950
  • [26] Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT
    Pan, Tinsu
    Thomas, M. Allan
    Luo, Dershan
    MEDICAL PHYSICS, 2022, 49 (06) : 3597 - 3611
  • [27] Phase retrieval: A data-driven wavelet frame based approach
    Pang, Tongyao
    Li, Qingna
    Wen, Zaiwen
    Shen, Zuowei
    APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2020, 49 (03) : 971 - 1000
  • [28] Variational bimodal image fusion with data-driven tight frame
    Zhang, Ying
    Zhang, Xiaoqun
    INFORMATION FUSION, 2020, 55 (55) : 164 - 172
  • [29] Direct Parametric Reconstruction With Joint Motion Estimation/Correction for Dynamic Brain PET Data
    Jiao, Jieqing
    Bousse, Alexandre
    Thielemans, Kris
    Burgos, Ninon
    Weston, Philip S. J.
    Schott, Jonathan M.
    Atkinson, David
    Arridge, Simon R.
    Hutton, Brian F.
    Markiewicz, Pawel
    Ourselin, Sebastien
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) : 203 - 213
  • [30] DATA-DRIVEN APPROACH FOR RESPIRATORY MOTION CORRECTION IN CARDIAC SPECT DATA
    Garmendia, Andoni, I
    Yang, Yongyi
    Song, Chao
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 1420 - 1423