Twenty-Four-Hour Real-Time Continuous Monitoring of Cerebral Edema in Rabbits Based on a Noninvasive and Noncontact System of Magnetic Induction

被引:23
|
作者
Li, Gen [1 ,2 ]
Ma, Ke [1 ]
Sun, Jian [1 ,3 ]
Jin, Gui [1 ]
Qin, Mingxin [1 ]
Feng, Hua [3 ]
机构
[1] Third Mil Med Univ, Coll Biomed Engn, Chongqing 400038, Peoples R China
[2] Chongqing Univ, Coll Bioengn, Chongqing 400030, Peoples R China
[3] Southwest Hosp, Dept Neurosurg, Chongqing 400038, Peoples R China
基金
中国国家自然科学基金;
关键词
cerebral edema; noncontact; magnetic induction; intracranial pressure; real-time monitoring; TRAUMATIC BRAIN-INJURY; INTRACRANIAL-PRESSURE; PHASE-SHIFT; HEMORRHAGE; TOMOGRAPHY; RATS; SPECTROSCOPY; ISCHEMIA; TISSUE;
D O I
10.3390/s17030537
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cerebral edema is a common disease, secondary to craniocerebral injury, and real-time continuous monitoring of cerebral edema is crucial for treating patients after traumatic brain injury. This work established a noninvasive and noncontact system by monitoring the magnetic induction phase shift (MIPS) which is associated with brain tissue conductivity. Sixteen rabbits (experimental group n = 10, control group, n = 6) were used to perform a 24 h MIPS and intracranial pressure (ICP) simultaneously monitored experimental study. For the experimental group, after the establishment of epidural freeze-induced cerebral edema models, the MIPS presented a downward trend within 24 h, with a change magnitude of -13.1121 +/- 2.3953 degrees; the ICP presented an upward trend within 24 h, with a change magnitude of 12-41 mmHg. The ICP was negatively correlated with the MIPS. In the control group, the MIPS change amplitude was -0.87795 +/- 1.5146 without obvious changes; the ICP fluctuated only slightly at the initial value of 12 mmHg. MIPS had a more sensitive performance than ICP in the early stage of cerebral edema. These results showed that this system is basically capable of monitoring gradual increases in the cerebral edema solution volume. To some extent, the MIPS has the potential to reflect the ICP changes.
引用
收藏
页数:12
相关论文
共 7 条
  • [1] Twenty-four-hour real-time continuous monitoring of acute focal cerebral ischemia in rabbits based on magnetic inductive phase shift
    Zhao, Shuang-Lin
    Jin, Gui
    Bai, Ze-Lin
    Chen, Jing-Bo
    Li, Meng-Wei
    Li, Gen
    Zhuang, Wei
    Liu, Yue-Ning
    Qin, Ming-Xin
    BIOMEDICAL ENGINEERING ONLINE, 2020, 19 (01)
  • [2] A noninvasive flexible conformal sensor for accurate real-time monitoring of local cerebral edema based on electromagnetic induction
    Chen, Jingbo
    Li, Gen
    Chen, Mingsheng
    Jin, Gui
    Zhao, Shuanglin
    Bai, Zelin
    Yang, Jun
    Liang, Huayou
    Xu, Jia
    Sun, Jian
    Qin, Mingxin
    PEERJ, 2020, 8
  • [3] A non-invasive real-time monitoring system for cytotoxic brain edema in post ischemic stroke based on near-field coupling
    Li, Gen
    Zhang, Bo
    Zhang, Maoting
    Liu, Qi
    Luo, Jie
    Liao, Qi
    Tan, Mei
    Bai, Zelin
    Xu, Jia
    Sun, Jian
    Chen, Mingsheng
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (05) : 963 - 978
  • [4] Noninvasive real-time detection of cerebral blood perfusion in hemorrhagic shock rabbits based on whole-brain magnetic induction phase shift: an experimental study
    Pan, Wencai
    Zhuang, Wei
    Chong, Yinbao
    Qin, Mingxin
    Li, Yang
    Xiao, Jingjing
    Wang, Qing
    Zhang, Shihui
    Zhao, Shuanglin
    Zhao, Peng
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (09)
  • [5] Real-time detection of cerebral edema in mice based on low-field nuclear magnetic resonance
    He, Yu
    Rao, Xiaoyong
    Zhan, Yang
    Tao, Qing
    He, Yan
    Fu, Xiaoming
    Zeng, Yan
    Luo, Xiaojian
    Lu, Haowei
    Liu, Wei
    MICROCHEMICAL JOURNAL, 2024, 207
  • [6] A Clinical Research on Real-Time Monitoring of Cerebral Edema After Basal Ganglia Hemorrhage Based on Near-Field Coupling Phase Shift Technology
    Sun, Jian
    Chen, Jingbo
    Li, Gen
    Xu, Lin
    Ren, Jian
    Chen, Mingsheng
    Xu, Jia
    Bai, Zeling
    Yang, Jun
    Chen, Yujie
    Qin, Mingxin
    Leung, Kwok-Wa
    IEEE ACCESS, 2019, 7 : 123736 - 123745
  • [7] A Non-Invasive Non-Contact Continuous Monitoring System of Brain Edema Based on Magnetic Induction Phase Shift and Computer Programming
    Li, Gen
    Zheng, Xiaolin
    Sun, Jian
    Ma, Ke
    Jin, Gui
    Feng, Hua
    Qin, Mingxin
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2017, 9 (10) : 1470 - 1477