Modeling and simulation of flexible needles

被引:63
作者
Goksel, Orcun [1 ]
Dehghan, Ehsan [1 ]
Salcudean, Septimiu E. [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Flexible needles; Modeling bending; Twisting/torsion; Angular springs; Brachytherapy simulation; INSERTION; DEFLECTION;
D O I
10.1016/j.medengphy.2009.07.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Needle insertion is performed in many clinical and therapeutic procedures. Tissue displacement and needle bending which result from needle-tissue interaction make accurate targeting difficult. For performing physicians to gain essential needle targeting skills, needle insertion simulators can be used for training. An accurate needle bending model is essential for such simulators. These bending models are also needed for needle path planning. In this paper, three different models are presented to simulate the deformations of a needle. The first two models use the finite element method and take the geometric nonlinearity into account. The third model is a series of rigid bars connected by angular springs. The models were compared to recorded deformations during experiments of applying lateral tip forces on a brachytherapy needle. The model parameters were identified and the simulation results were compared to the experimental data. The results show that the angular spring model, which is computationally the most efficient model, is also the most accurate in modeling the bending of the brachytherapy needle. (C) 2009 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1069 / 1078
页数:10
相关论文
共 28 条
[1]   Minimization of needte deflection in robot-assisted percutaneous therapy [J].
Abolhassani, Niki ;
Patel, Rajni V. ;
Ayazi, Farzam .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (02) :140-148
[2]   Motion Planning Under Uncertainty for Image-guided Medical Needle Steering [J].
Alterovitz, Ron ;
Branicky, Michael ;
Goldberg, Ken .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2008, 27 (11-12) :1361-1374
[3]  
[Anonymous], ACM SIGGRAPH COMPUT
[4]  
[Anonymous], 2000, METHODS
[5]  
[Anonymous], 2004, INTRO NONLINEAR FINI, DOI DOI 10.1093/ACPROF:OSO/978019-8525295.003.0002
[6]  
Bro-Nielsen M., 1996, COMPUT GRAPH FORUM, P57, DOI DOI 10.1111/1467-8659.1530057
[7]  
Crouch JR, 2005, LECT NOTES COMPUT SC, V3750, P624, DOI 10.1007/11566489_77
[8]   Needle-tissue interaction modeling using ultrasound-based motion estimation: Phantom study [J].
Dehghan, Ehsan ;
Wen, Xu ;
Zahiri-Azar, Reza ;
Marchal, Maud ;
Salcudean, Septimiu E. .
COMPUTER AIDED SURGERY, 2008, 13 (05) :265-280
[9]  
Dehghan E, 2006, LECT NOTES COMPUT SC, V4190, P305
[10]   Needle Insertion Parameter Optimization for Brachytherapy [J].
Dehghan, Ehsan ;
Salcudean, Septimiu E. .
IEEE TRANSACTIONS ON ROBOTICS, 2009, 25 (02) :303-315