Anatomic relations of the thoracic pedicle to the adjacent neural structures

被引:166
作者
Ebraheim, NA [1 ]
Jabaly, G [1 ]
Xu, RM [1 ]
Yeasting, RA [1 ]
机构
[1] MED COLL OHIO, DEPT ANAT, TOLEDO, OH 43699 USA
关键词
anatomy; nerve root; pedicular screw placement; thoracic spine;
D O I
10.1097/00007632-199707150-00002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This study analyzed anatomic parameters between the thoracic pedicles and the spinal nerve roots. Objectives. To quantitatively determine the anatomic relations of the thoracic pedicle to the adjacent neural structures. Summary of Background Data. Pedicular screw placement carries with it potential hazard to the sur rounding neural structures, especially in the thoracic spine. No studies exist regarding the anatomic relations of the thoracic pedicle to the adjacent nerve roots. Methods. Fifteen cadavers were obtained for study of the thoracic spine. All soft tissue was dissected off the thoracic spine. Laminectomy and total removal of the superior and inferior articular facets was then per formed on C7-T1 through T12-L1 to expose the pedicles, nerve roots, and dura. Measurements were taken from the pedicle to the nerve root superiorly and inferiorly as well as between the pedicles. Also, the superoinferior diameter of the nerve root and the frontal angle of the nerve root were measured. Symmetrical structures were measured bilaterally. Results. The results showed that no epidural space could be found between the dural sac and the pedicle in all 15 cadavers. The average distances from the thoracic pedicle to the adjacent nerve roots superiorly or inferiorly at all levels ranged from 1.9 to 3.9 mm and from 1.7 to 2.8 mm, with a minimum of 1.3 mm, respectively. The interpedicular distance increased from T1 (13.8 mm) to T3, slightly decreased in T4-T5, then gradually increased to T12 (16.6 mm). The superoinferior diameter of the nerve root increased consistently from 2.9 mm at T1 to 4.6 mm at T11. The frontal nerve root angle decreased consistently from T1 (120.1 degrees) to T12 (57.1 degrees), except at T4-T5. Conclusions. This study suggested that more care be taken into consideration in placing a transpedicular screw in the transverse plane than in placing a screw in the sagittal plane in the thoracic spine.
引用
收藏
页码:1553 / 1556
页数:4
相关论文
共 18 条
  • [1] BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL
    ASHMAN, RB
    GALPIN, RD
    CORIN, JD
    JOHNSTON, CE
    [J]. SPINE, 1989, 14 (12) : 1398 - 1405
  • [2] A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE
    BERRY, JL
    MORAN, JM
    BERG, WS
    STEFFEE, AD
    [J]. SPINE, 1987, 12 (04) : 362 - 367
  • [3] DENIS F, 1988, ORTHOP CLIN N AM, V19, P291
  • [4] COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS
    ESSES, SI
    SACHS, BL
    DREYZIN, V
    [J]. SPINE, 1993, 18 (15) : 2231 - 2239
  • [5] HARRINGTON INSTRUMENTATION AND SPINE FUSION FOR UNSTABLE FRACTURES AND FRACTURE-DISLOCATIONS OF THORACIC AND LUMBAR SPINE
    FLESCH, JR
    LEIDER, LL
    ERICKSON, DL
    CHOU, SN
    BRADFORD, DS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (02) : 143 - 153
  • [6] PEDICLE MORPHOLOGY OF THE LOWER THORACIC AND LUMBAR SPINE IN A CHINESE POPULATION
    HOU, SX
    HU, R
    SHI, YM
    [J]. SPINE, 1993, 18 (13) : 1850 - 1855
  • [7] JACOBS RR, 1984, CLIN ORTHOP RELAT R, V189, P168
  • [8] Krag M H, 1988, J Spinal Disord, V1, P287
  • [9] MORPHOMETRY OF THE THORACIC AND LUMBAR SPINE RELATED TO TRANSPEDICULAR SCREW PLACEMENT FOR SURGICAL SPINAL FIXATION
    KRAG, MH
    WEAVER, DL
    BEYNNON, BD
    HAUGH, LD
    [J]. SPINE, 1988, 13 (01) : 27 - 32
  • [10] LOUIS R, 1986, CLIN ORTHOP RELAT R, V203, P18