Evaluation of dose from kV cone-beam computed tomography during radiotherapy: a comparison of methodologies

被引:0
作者
Buckley, J. [1 ]
Wilkinson, D. [2 ]
Malaroda, A. [1 ]
Metcalfe, P. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[2] Wollongong Hosp, Illawarra Canc Care Ctr, Wollongong, NSW 2500, Australia
来源
MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016) | 2017年 / 777卷
关键词
CT; DOSIMETRY;
D O I
10.1088/1742-6596/777/1/012003
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Three alternative methodologies to the Computed-Tomography Dose Index for the evaluation of Cone-Beam Computed Tomography dose are compared, the Cone-Beam Dose Index, IAEA Human Health Report No. 5 recommended methodology and the AAPM Task Group 111 recommended methodology. The protocols were evaluated for Pelvis and Thorax scan modes on Varian (R) On-Board Imager and Truebeam kV XI imaging systems. The weighted planar average dose was highest for the AAPM methodology across all scans, with the CBDI being the second highest overall. A 17.96% and 1.14% decrease from the TG-111 protocol to the IAEA and CBDI protocols for the Pelvis mode and 18.15% and 13.10% decrease for the Thorax mode were observed for the XI system. For the OBI system, the variation was 16.46% and 7.14% for Pelvis mode and 15.93% to the CBDI protocol in Thorax mode respectively.
引用
收藏
页数:4
相关论文
共 14 条
[1]   Imaging doses from the Elekta Synergy X-ray cone beam CT system [J].
Amer, A. ;
Marchant, T. ;
Sykes, J. ;
Czajka, J. ;
Moore, C. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954) :476-482
[2]  
[Anonymous], 2010, Comprehensive methodology for the evaluation of radiation dose in xray computed tomography (111)
[3]  
Boda-Heggermann J, 2011, J STRAH ONKOL, V187, P284
[4]   The trouble with CTDI100 [J].
Boone, John M. .
MEDICAL PHYSICS, 2007, 34 (04) :1364-1371
[5]  
Dixon RL, 2003, MED PHYS, V30, P1272, DOI 10.1118/1.1576952
[6]   Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams [J].
Greer, Peter B. ;
Vial, Philip ;
Oliver, Lyn ;
Baldock, Clive .
MEDICAL PHYSICS, 2007, 34 (11) :4389-4398
[7]   Polymer gel dosimetry on a multislice computed tomography scanner: Effect of changing parameters on CTDI [J].
Hill, B. ;
Venning, A. J. ;
Baldock, C. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (03) :149-158
[8]   A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners [J].
Hill, B ;
Venning, AJ ;
Baldock, C .
MEDICAL PHYSICS, 2005, 32 (06) :1589-1597
[9]  
IAEA, 2011, HUM HLTH REP SER
[10]  
Kim D, 2013, HEALTH PHYS, V104, P999