The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time

被引:31
|
作者
Yousefian, Peyman [1 ]
Shin, Sungtae [1 ]
Mousavi, Azin [1 ]
Kim, Chang-Sei [2 ]
Mukkamala, Ramakrishna [3 ]
Jang, Dae-Geun [4 ]
Ko, Byung-Hoon [4 ]
Lee, Jongwook [4 ]
Kwon, Ui Kun [4 ]
Kim, Youn Ho [4 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[4] Samsung Adv Inst Technol, Device & Syst Res Ctr, Suwon, Gyeonggi, South Korea
关键词
HEART-RATE; CARDIOVASCULAR-RESPONSE; BREATHING RATE; DECREASES; STRESS; DEVICE;
D O I
10.1038/s41598-019-46936-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE= 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.
引用
收藏
页数:11
相关论文
共 45 条
  • [41] Accuracy of pulse rate derived from 24-h ambulatory blood pressure monitoring compared with heart rate from 24-h Holter-ECG
    Lauder, Lucas
    Scholz, Sean S.
    Ewen, Sebastian
    Lettner, Christine
    Ukena, Christian
    Bohm, Michael
    Mahfoud, Felix
    JOURNAL OF HYPERTENSION, 2020, 38 (12) : 2387 - 2392
  • [42] Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysis
    Saugel, Bernd
    Hoppe, Phillip
    Nicklas, Julia Y.
    Kouz, Karim
    Koerner, Annmarie
    Hempell, Julia C.
    Vos, Jaap J.
    Schoen, Gerhard
    Scheeren, Thomas W. L.
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (01) : 25 - 37
  • [43] Diagnosing silent cardiac dysautonomia via ambulatory blood pressure monitoring: early diagnosis shown by the lack of heart rate circadian rhythm in type 1 diabetes mellitus
    Cugini, P.
    Amato, S.
    Tarquini, G.
    Mercuri, S.
    Turinese, I.
    Tego, A.
    Rossetti, M.
    Panetti, D.
    Filardi, T.
    Curione, M.
    Morano, S.
    CLINICA TERAPEUTICA, 2010, 161 (01): : E1 - E10
  • [44] Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery
    Sun, Jing
    Chen, Hanjian
    Zheng, Jun
    Mao, Bin
    Zhu, Shengmei
    Feng, Jingyi
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (06) : 1189 - 1195
  • [45] Validation of Omron HEM-7600T, a wearable device for monitoring blood pressure, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol in the general population without arrhythmias
    Takahashi, Hakuo
    Saito, Kanako
    Hishiki, Yukiko
    BLOOD PRESSURE MONITORING, 2021, 26 (02) : 156 - 159