The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time

被引:31
|
作者
Yousefian, Peyman [1 ]
Shin, Sungtae [1 ]
Mousavi, Azin [1 ]
Kim, Chang-Sei [2 ]
Mukkamala, Ramakrishna [3 ]
Jang, Dae-Geun [4 ]
Ko, Byung-Hoon [4 ]
Lee, Jongwook [4 ]
Kwon, Ui Kun [4 ]
Kim, Youn Ho [4 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[4] Samsung Adv Inst Technol, Device & Syst Res Ctr, Suwon, Gyeonggi, South Korea
关键词
HEART-RATE; CARDIOVASCULAR-RESPONSE; BREATHING RATE; DECREASES; STRESS; DEVICE;
D O I
10.1038/s41598-019-46936-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE= 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.
引用
收藏
页数:11
相关论文
共 45 条
  • [21] Multi-Site Pulse Transit Times, Beat-to-Beat Blood Pressure, and Isovolumic Contraction Time at Rest and Under Stressors
    Di Rienzo, Marco
    Avolio, Alberto
    Rizzo, Giovannibattista
    Zeybek, Zeynep Melike Isilay
    Cucugliato, Luisa
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (02) : 561 - 571
  • [22] Beat-to-Beat Tracking of Systolic Blood Pressure Using Noninvasive Pulse Transit Time During Anesthesia Induction in Hypertensive Patients
    Kim, Sung-Hoon
    Song, Jun-Gol
    Park, Ji-Hyun
    Kim, Jung-Won
    Park, Yong-Seok
    Hwang, Gyu-Sam
    ANESTHESIA AND ANALGESIA, 2013, 116 (01) : 94 - 100
  • [23] Psycho-physiological Stress Monitoring using Mobile and Continous Pulse Transit Time Measurement
    Hey, Stefan
    Sghir, Hatem
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EHEALTH, TELEMEDICINE, AND SOCIAL MEDICINE (ETELEMED 2011), 2011, : 126 - 129
  • [24] Blood pressure altering method affects correlation with pulse arrival time
    Heimark, Sondre
    Rindal, Ole Marius H.
    Seeberg, Trine M.
    Stepanov, Alexey
    Boysen, Elin S.
    Botker-Rasmussen, Kasper G.
    Mobaek, Nina K.
    Soraas, Camilla L.
    Stenehjem, Aud E.
    Elmula, Fadl Elmula M. Fadl
    Waldum-Grevbo, Bard
    BLOOD PRESSURE MONITORING, 2022, 27 (02) : 139 - 146
  • [25] Time-independent indices of circadian blood pressure and heart rate regulation from ambulatory blood pressure monitoring
    Pizzinelli, Paolo
    Iellamo, Ferdinando
    Beltrami, Silvia
    Lucini, Daniela
    Pagani, Massimo
    JOURNAL OF HYPERTENSION, 2009, 27 (06) : 1178 - 1185
  • [26] Influence of Blood Pressure and Heart Rate on PWV Measurement: Assessment Under Real-Time Blood Pressure Monitoring
    Liu, Jinping
    An, Bojing
    Shi, Baixue
    Li, Xuejie
    Qian, Linxue
    PHYSIOLOGICAL RESEARCH, 2024, 73 (06) : 963 - 971
  • [27] Portable Non-invasive Blood Pressure Measurement using Pulse Transmit Time
    Noche, Kaiser Josephus B.
    Flores Villaverde, Jocelyn
    Lazaro, Jose, Jr.
    2017 IEEE 9TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT AND MANAGEMENT (IEEE HNICEM), 2017,
  • [28] Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors
    Baek, Hyun Jae
    Kim, Ko Keun
    Kim, Jung Soo
    Lee, Boreom
    Park, Kwang Suk
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (02) : 145 - 157
  • [29] Time-qualified reference values for ambulatory blood pressure monitoring in pregnancy
    Hermida, RC
    Ayala, DE
    Mojón, A
    Fernández, JR
    HYPERTENSION, 2001, 38 (03) : 746 - 752
  • [30] The optimal night-time home blood pressure monitoring schedule: agreement with ambulatory blood pressure and association with organ damage
    Kollias, Anastasios
    Andreadis, Emmanuel
    Agaliotis, Gerasimos
    Kolyvas, George N.
    Achimastos, Apostolos
    Stergiou, George S.
    JOURNAL OF HYPERTENSION, 2018, 36 (02) : 243 - 249