The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time

被引:31
|
作者
Yousefian, Peyman [1 ]
Shin, Sungtae [1 ]
Mousavi, Azin [1 ]
Kim, Chang-Sei [2 ]
Mukkamala, Ramakrishna [3 ]
Jang, Dae-Geun [4 ]
Ko, Byung-Hoon [4 ]
Lee, Jongwook [4 ]
Kwon, Ui Kun [4 ]
Kim, Youn Ho [4 ]
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Chonnam Natl Univ, Sch Mech Engn, Gwangju, South Korea
[3] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[4] Samsung Adv Inst Technol, Device & Syst Res Ctr, Suwon, Gyeonggi, South Korea
关键词
HEART-RATE; CARDIOVASCULAR-RESPONSE; BREATHING RATE; DECREASES; STRESS; DEVICE;
D O I
10.1038/s41598-019-46936-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE= 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.
引用
收藏
页数:11
相关论文
共 45 条
  • [1] Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring
    Kim, Chang-Sei
    Carek, Andrew M.
    Mukkamala, Ramakrishna
    Inan, Omer T.
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (11) : 2657 - 2664
  • [2] Pulse Transit Time-Pulse Wave Analysis Fusion Based on Wearable Wrist Ballistocardiogram for Cuff-Less Blood Pressure Trend Tracking
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin Sadat
    Tivay, Ali
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung Hoon
    Lee, Jongwook
    Kwon, Ui-Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE ACCESS, 2020, 8 : 138077 - 138087
  • [3] Data mining investigation of the association between a limb ballistocardiogram and blood pressure
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung-Hoon
    Lee, Jongwook
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (07)
  • [4] Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice
    Mukkamala, Ramakrishna
    Hahn, Jin-Oh
    Inan, Omer T.
    Mestha, Lalit K.
    Kim, Chang-Sei
    Toreyin, Hakan
    Kyal, Survi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 1879 - 1901
  • [5] Posture-Dependent Variability in Wrist Ballistocardiogram-Photoplethysmogram Pulse Transit Time: Implication to Cuff-Less Blood Pressure Tracking
    Shin, Sungtae
    Mousavi, Azin
    Lyle, Sophia
    Jang, Elisabeth
    Yousefian, Peyman
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (01) : 347 - 355
  • [6] An implantable optical blood pressure sensor based on pulse transit time
    Fiala, Jens
    Bingger, Philipp
    Ruh, Dominic
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    BIOMEDICAL MICRODEVICES, 2013, 15 (01) : 73 - 81
  • [7] Continuous monitoring of cerebrovascular reactivity through pulse transit time and intracranial pressure
    Liu, Xiuyun
    Gadhoumi, Kais
    Xiao, Ran
    Tran, Nate
    Smielewski, Peter
    Czosnyka, Marek
    Hetts, Steven W.
    Ko, Nerissa
    Hu, Xiao
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (01)
  • [8] PULSE TRANSIT-TIME - RELATIONSHIP TO BLOOD-PRESSURE AND MYOCARDIAL PERFORMANCE
    OBRIST, PA
    LIGHT, KC
    MCCUBBIN, JA
    HUTCHESON, JS
    HOFFER, JL
    PSYCHOPHYSIOLOGY, 1979, 16 (03) : 292 - 301
  • [9] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [10] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976