Long-length tomosynthesis and 3D-2D registration for intraoperative assessment of spine instrumentation

被引:11
|
作者
Zhang, Xiaoxuan [1 ]
Uneri, Ali [1 ]
Wu, Pengwei [1 ]
Ketcha, Michael Daniel [1 ]
Jones, Craig K. [2 ]
Huang, Yixuan [1 ]
Lo, Sheng-Fu Larry [3 ]
Helm, Patrick A. [4 ]
Siewerdsen, Jeffrey H. [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Neurosurg, Baltimore, MD 21218 USA
[4] Medtronic, Littleton, MA USA
关键词
tomosynthesis; 3D-2D registration; image-guided surgery; intraoperative imaging; spine surgery; spinal alignment; PEDICLE SCREW PLACEMENT; COMPUTED-TOMOGRAPHY; IMAGE REGISTRATION; ACCURACY; SURGERY; RADIOGRAPHY; QUALITY; COMPLICATIONS; LOCALIZATION; SCOLIOSIS;
D O I
10.1088/1361-6560/abde96
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. Methods. A multi-slot collimator with tilted apertures was integrated into an O-arm system for long-length imaging. The multi-slot projective geometry leads to slight view disparity in both long-length projection images (referred to as 'line scans') and tomosynthesis 'slot reconstructions' produced using a weighted-backprojection method. The radiation dose for long-length imaging was measured, and the utility of long-length, intraoperative tomosynthesis was evaluated in phantom and cadaver studies. Leveraging the depth resolution provided by parallax views, an algorithm for 3D-2D registration of the patient and surgical devices was adapted for registration with line scans and slot reconstructions. Registration performance using single-plane or dual-plane long-length images was evaluated and compared to registration accuracy achieved using standard dual-plane radiographs. Results. Longitudinal coverage of similar to 50-64 cm was achieved with a single long-length slot scan, providing a field-of-view (FOV) up to (40 x 64) cm(2), depending on patient positioning. The dose-area product (reference point air kerma x x-ray field area) for a slot scan ranged from similar to 702-1757 mGycm(2), equivalent to similar to 2.5 s of fluoroscopy and comparable to other long-length imaging systems. Long-length scanning produced high-resolution tomosynthesis reconstructions, covering similar to 12-16 vertebral levels. 3D image registration using dual-plane slot reconstructions achieved median target registration error (TRE) of 1.2 mm and 0.6 degrees in cadaver studies, outperforming registration to dual-plane line scans (TRE = 2.8 mm and 2.2 degrees) and radiographs (TRE = 2.5 mm and 1.1 degrees). 3D registration using single-plane slot reconstructions leveraged the similar to 7-14 degrees angular separation between slots to achieve median TRE similar to 2 mm and Conclusion. The multi-slot configuration provided intraoperative visualization of long spine segments, facilitating target localization, assessment of global spinal alignment, and evaluation of long surgical constructs. 3D-2D registration to long-length tomosynthesis reconstructions yielded a promising means of guidance and verification with accuracy exceeding that of 3D-2D registration to conventional radiographs.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Data-Driven Deformable 3D-2D Registration for Guiding Neuroelectrode Placement in Deep Brain Stimulation
    Uneri, A.
    Wu, P.
    Jones, C. K.
    Ketcha, M. D.
    Vagdargi, P.
    Han, R.
    Helm, P. A.
    Luciano, M.
    Anderson, W. S.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2021: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11598
  • [22] Self-calibration of cone-beam CT geometry using 3D-2D image registration
    Ouadah, S.
    Stayman, J. W.
    Gang, G. J.
    Ehtiati, T.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) : 2613 - 2632
  • [23] Deformable 3D-2D registration for CT and its application to low dose tomographic fluoroscopy
    Flach, Barbara
    Brehm, Marcus
    Sawall, Stefan
    Kachelriess, Marc
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24) : 7865 - 7887
  • [24] A framework for automatic creation of gold-standard rigid 3D-2D registration datasets
    Madan, Hennadii
    Pernu, Franjo
    Likar, Botjan
    Spiclin, Ziga
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (02) : 263 - 275
  • [25] 3D-2D Registration Using X-Ray Simulation and CMA-ES
    Wen, Tianci
    Mihail, Radu P.
    Vidal, Franck P.
    APPLICATIONS OF EVOLUTIONARY COMPUTATION, EVOAPPLICATIONS 2021, 2021, 12694 : 453 - 468
  • [26] Deformable 3D-2D registration for high-precision guidance and verification of neuroelectrode placement
    Uneri, A.
    Wu, P.
    Jones, C. K.
    Vagdargi, P.
    Han, R.
    Helm, P. A.
    Luciano, M. G.
    Anderson, W. S.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (21)
  • [27] Correction of patient motion in cone-beam CT using 3D-2D registration
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23) : 8813 - 8831
  • [28] Dual-Projection 3D-2D Registration for Surgical Guidance: Preclinical Evaluation of Performance and Minimum Angular Separation
    Uneri, A.
    Otake, Y.
    Wang, A. S.
    Kleinszig, G.
    Vogt, S.
    Gallia, G. L.
    Rigamonti, D.
    Wolinsky, J. -P.
    Gokaslan, Z. L.
    Khanna, A. J.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [29] In vivo kinematic study of the tarsal joints complex based on fluoroscopic 3D-2D registration technique
    Wang, Chen
    Geng, Xiang
    Wang, Shaobai
    Ma, Xin
    Wang, Xu
    Huang, Jiazhang
    Zhang, Chao
    Chen, Li
    Yang, Junsheng
    Wang, Kan
    GAIT & POSTURE, 2016, 49 : 54 - 60
  • [30] Assessment of spline-based 2D-3D registration for image-guided spine surgery
    Zhang, Xuan
    Zheng, Guoyan
    Langlotz, Frank
    Nolte, Lutz-Peter
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2006, 15 (03) : 193 - 199