Epidermal innervation morphometry by immunofluorescence and bright-field microscopy

被引:28
|
作者
Nolano, Maria [1 ]
Biasiotta, Antonella [2 ]
Lombardi, Raffaella [3 ,4 ]
Provitera, Vincenzo [1 ]
Stancanelli, Annamaria [1 ]
Caporaso, Giuseppe [1 ]
Santoro, Lucio [5 ]
Merkies, Ingemar S. J. [6 ]
Truini, Andrea [2 ]
Porretta-Serapiglia, Carla [3 ,4 ]
Cazzato, Daniele [3 ,4 ]
Dacci, Patrizia [3 ,4 ]
Vitale, Dino F. [1 ]
Lauria, Giuseppe [3 ,4 ]
机构
[1] Salvatore Maugeri Fdn, Inst Telese Terme BN, Telese Terme, BN, Italy
[2] Univ Roma La Sapienza, Dept Neurol & Psychiat, I-00185 Rome, Italy
[3] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Neurol Unit 3, I-20133 Milan, Italy
[4] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Skin Biopsy Peripheral Neuropathy & Neuropath Pai, I-20133 Milan, Italy
[5] Univ Naples Federico II, Dept Neurosci Reprod Sci & Odontostomatol, Naples, Italy
[6] Spaarne Hosp, Dept Neurol, Hoofddorp, Netherlands
关键词
immunofluorescence; immunohistochemistry; intraepidermal nerve fiber; painful neuropathy; skin biopsy; NERVE-FIBER DENSITY; SKIN BIOPSY; NEUROPATHIES;
D O I
10.1111/jns.12146
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We investigated the agreement between simple indirect immunofluorescence (IF) and bright-field immunohistochemistry (BFI) on free-floating sections for intraepidermal nerve fiber density (IENFD) quantification. Fifty-five healthy subjects and 63 patients with probable small fiber neuropathy (SFN) underwent two adjacent skin biopsies at the distal leg processed by IF and BFI technique. Agreement between IENFD pairs obtained by each method was assessed by Bland-Altman testing. The area under the curve of the receiving operating characteristics (ROC) curves was used to compare the discrimination ability. The diagnostic judgment was based on sex and age-adjusted normative values. IF and BFI showed good correlation (r = 0.81), with a ratio of about 2: 1 and a mean difference of 5.5 +/- 3.0 IENF per millimeter between paired measures, as demonstrated by linear regression and Bland-Altman test analyses. The square root transformation confirmed a Poisson distribution of the data and a fixed bias between IF and BFI measurements. The ROC curves analysis demonstrated a striking overlap between IF and BFI (0.83 and 0.82; p = 0.72). The diagnosis of SFN disagreed in only 6.7% of cases when the judgment was based on a difference of > 1 IENF from 5% cut-off value. IF and BFI showed comparable diagnostic efficiency when referred to appropriate normative reference values.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [31] Simulation of Bright-Field Microscopy Images Depicting Pap-Smear Specimen
    Malm, Patrik
    Brun, Anders
    Bengtsson, Ewert
    CYTOMETRY PART A, 2015, 87A (03) : 212 - 226
  • [32] Spatially-incoherent annular illumination microscopy for bright-field optical sectioning
    Ma, Xiao
    Zhang, Zibang
    Yao, Manhong
    Peng, Junzheng
    Zhong, Jingang
    ULTRAMICROSCOPY, 2018, 195 : 74 - 84
  • [33] The Detection of Isolated Tumor Cells in Bone Marrow Comparing Bright-Field Immunocytochemistry and Multicolor Immunofluorescence
    David N. Krag
    Roberto Kusminsky
    Edward Manna
    Abiy Ambaye
    Donald L. Weaver
    Seth P. Harlow
    Michael Covelli
    Mary A. Stanley
    Laurence McCahill
    Frank Ittleman
    Bruce Leavitt
    Martin Krag
    Annals of Surgical Oncology, 2005, 12 : 753 - 760
  • [34] Experimental examination of the characteristics of bright-field scanning confocal electron microscopy images
    Hashimoto, Ayako
    Mitsuishi, Kazutaka
    Shimojo, Masayuki
    Zhu, Yufang
    Takeguchi, Masaki
    JOURNAL OF ELECTRON MICROSCOPY, 2011, 60 (03): : 227 - 234
  • [35] Computational image translation from Mueller matrix polarimetry to bright-field microscopy
    Si, Lu
    Li, Naiqi
    Huang, Tongyu
    Du, Shan
    Dong, Yang
    Yao, Yue
    Ma, Hui
    JOURNAL OF BIOPHOTONICS, 2022, 15 (03)
  • [36] Image processing for combined bright-field and reflection interference contrast video microscopy
    Weber, I
    Albrecht, R
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1997, 53 (02) : 113 - 118
  • [37] Imaging properties of bright-field and annular-dark-field scanning confocal electron microscopy
    Mitsuishi, K.
    Hashimoto, A.
    Takeguchi, M.
    Shimojo, M.
    Ishizuka, K.
    ULTRAMICROSCOPY, 2010, 111 (01) : 20 - 26
  • [38] Bright-field quantitative phase microscopy (BFQPM) for accurate phase imaging using conventional microscopy hardware
    Jenkins, Micah
    Gaylord, Thomas K.
    QUANTITATIVE PHASE IMAGING, 2015, 9336
  • [39] Quasi-spectral characterization of intracellular regions in bright-field light microscopy images
    Kirill Lonhus
    Renata Rychtáriková
    Ganna Platonova
    Dalibor Štys
    Scientific Reports, 10
  • [40] Quasi-spectral characterization of intracellular regions in bright-field light microscopy images
    Lonhus, Kirill
    Rychtarikova, Renata
    Platonova, Ganna
    Stys, Dalibor
    SCIENTIFIC REPORTS, 2020, 10 (01)