Epidermal innervation morphometry by immunofluorescence and bright-field microscopy

被引:28
|
作者
Nolano, Maria [1 ]
Biasiotta, Antonella [2 ]
Lombardi, Raffaella [3 ,4 ]
Provitera, Vincenzo [1 ]
Stancanelli, Annamaria [1 ]
Caporaso, Giuseppe [1 ]
Santoro, Lucio [5 ]
Merkies, Ingemar S. J. [6 ]
Truini, Andrea [2 ]
Porretta-Serapiglia, Carla [3 ,4 ]
Cazzato, Daniele [3 ,4 ]
Dacci, Patrizia [3 ,4 ]
Vitale, Dino F. [1 ]
Lauria, Giuseppe [3 ,4 ]
机构
[1] Salvatore Maugeri Fdn, Inst Telese Terme BN, Telese Terme, BN, Italy
[2] Univ Roma La Sapienza, Dept Neurol & Psychiat, I-00185 Rome, Italy
[3] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Neurol Unit 3, I-20133 Milan, Italy
[4] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Skin Biopsy Peripheral Neuropathy & Neuropath Pai, I-20133 Milan, Italy
[5] Univ Naples Federico II, Dept Neurosci Reprod Sci & Odontostomatol, Naples, Italy
[6] Spaarne Hosp, Dept Neurol, Hoofddorp, Netherlands
关键词
immunofluorescence; immunohistochemistry; intraepidermal nerve fiber; painful neuropathy; skin biopsy; NERVE-FIBER DENSITY; SKIN BIOPSY; NEUROPATHIES;
D O I
10.1111/jns.12146
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We investigated the agreement between simple indirect immunofluorescence (IF) and bright-field immunohistochemistry (BFI) on free-floating sections for intraepidermal nerve fiber density (IENFD) quantification. Fifty-five healthy subjects and 63 patients with probable small fiber neuropathy (SFN) underwent two adjacent skin biopsies at the distal leg processed by IF and BFI technique. Agreement between IENFD pairs obtained by each method was assessed by Bland-Altman testing. The area under the curve of the receiving operating characteristics (ROC) curves was used to compare the discrimination ability. The diagnostic judgment was based on sex and age-adjusted normative values. IF and BFI showed good correlation (r = 0.81), with a ratio of about 2: 1 and a mean difference of 5.5 +/- 3.0 IENF per millimeter between paired measures, as demonstrated by linear regression and Bland-Altman test analyses. The square root transformation confirmed a Poisson distribution of the data and a fixed bias between IF and BFI measurements. The ROC curves analysis demonstrated a striking overlap between IF and BFI (0.83 and 0.82; p = 0.72). The diagnosis of SFN disagreed in only 6.7% of cases when the judgment was based on a difference of > 1 IENF from 5% cut-off value. IF and BFI showed comparable diagnostic efficiency when referred to appropriate normative reference values.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [21] Phase reconstruction in annular bright-field scanning transmission electron microscopy
    Ishida, Takafumi
    Kawasaki, Tadahiro
    Tanji, Takayoshi
    Kodama, Tetsuji
    Matsutani, Takaomi
    Ogai, Keiko
    Ikuta, Takashi
    MICROSCOPY, 2015, 64 (02) : 69 - 76
  • [22] Experimental test of the geometric model of image formation in bright-field microscopy
    Clements, R. J.
    Davidson, M.
    Model, M. A.
    JOURNAL OF MICROSCOPY, 2021, 283 (01) : 3 - 8
  • [23] A new method for increasing the depth of focus in bright-field light microscopy
    Ozaki, D
    Kondo, Y
    LABORATORY INVESTIGATION, 1998, 78 (10) : 1339 - 1340
  • [24] Automatic cell detection in bright-field microscopy for microbeam irradiation studies
    Georgantzoglou, A.
    Merchant, M. J.
    Jeynes, J. C. G.
    Wera, A-C
    Kirkby, K. J.
    Kirkby, N. F.
    Jena, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16): : 6289 - 6303
  • [25] Pollen segmentation and feature evaluation for automatic classification in bright-field microscopy
    Redondo, Rafael
    Bueno, Gloria
    Chung, Francois
    Nava, Rodrigo
    Victor Marcos, J.
    Cristobal, Gabriel
    Rodriguez, Tomas
    Gonzalez-Porto, Amelia
    Pardo, Cristina
    Deniz, Oscar
    Escalante-Ramirez, B.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2015, 110 : 56 - 69
  • [26] Performance of microsphere-assisted imaging in bright-field and dark-field microscopy
    Guo, Hongmei
    Wang, Dong
    Liu, Yong
    Jang, Rui
    Huang, Rong
    Cao, Yurong
    Ye, Yong-Hong
    OPTICS EXPRESS, 2024, 32 (22): : 38910 - 38919
  • [27] Automated morphometry toolbox for analysis of microscopic model organisms using simple bright-field imaging
    Liu, Guanghui
    Dong, Fenfen
    Fu, Chuanhai
    Smith, Zachary J.
    BIOLOGY OPEN, 2019, 8 (03):
  • [28] The detection of isolated tumor cells in bone marrow comparing bright-field immunocytochemistry and multicolor immunofluorescence
    Krag, DN
    Kusminsky, R
    Manna, E
    Ambaye, A
    Weaver, DL
    Harlow, SP
    Covelli, M
    Stanley, MA
    McCahill, L
    Ittleman, F
    Leavitt, B
    Krag, M
    ANNALS OF SURGICAL ONCOLOGY, 2005, 12 (09) : 753 - 760
  • [29] DEMONSTRATION OF MAST-CELLS BY INTRAVITAL BRIGHT-FIELD RESP FLUORESCENCE MICROSCOPY
    KOBYLINSKI, S
    EXPERIMENTELLE PATHOLOGIE, 1972, 7 (3-4): : 142 - 146
  • [30] Image Preprocessing Pipeline for Bright-Field Miniature Live Cell Microscopy Prototypes
    Schoell, S.
    Mualla, F.
    Sommerfeldt, B.
    Steidl, S.
    Maier, A.
    INTERNATIONAL MULTIDISCIPLINARY MICROSCOPY CONGRESS, 2014, 154 : 261 - 267