Epidermal innervation morphometry by immunofluorescence and bright-field microscopy

被引:28
|
作者
Nolano, Maria [1 ]
Biasiotta, Antonella [2 ]
Lombardi, Raffaella [3 ,4 ]
Provitera, Vincenzo [1 ]
Stancanelli, Annamaria [1 ]
Caporaso, Giuseppe [1 ]
Santoro, Lucio [5 ]
Merkies, Ingemar S. J. [6 ]
Truini, Andrea [2 ]
Porretta-Serapiglia, Carla [3 ,4 ]
Cazzato, Daniele [3 ,4 ]
Dacci, Patrizia [3 ,4 ]
Vitale, Dino F. [1 ]
Lauria, Giuseppe [3 ,4 ]
机构
[1] Salvatore Maugeri Fdn, Inst Telese Terme BN, Telese Terme, BN, Italy
[2] Univ Roma La Sapienza, Dept Neurol & Psychiat, I-00185 Rome, Italy
[3] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Neurol Unit 3, I-20133 Milan, Italy
[4] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Skin Biopsy Peripheral Neuropathy & Neuropath Pai, I-20133 Milan, Italy
[5] Univ Naples Federico II, Dept Neurosci Reprod Sci & Odontostomatol, Naples, Italy
[6] Spaarne Hosp, Dept Neurol, Hoofddorp, Netherlands
关键词
immunofluorescence; immunohistochemistry; intraepidermal nerve fiber; painful neuropathy; skin biopsy; NERVE-FIBER DENSITY; SKIN BIOPSY; NEUROPATHIES;
D O I
10.1111/jns.12146
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We investigated the agreement between simple indirect immunofluorescence (IF) and bright-field immunohistochemistry (BFI) on free-floating sections for intraepidermal nerve fiber density (IENFD) quantification. Fifty-five healthy subjects and 63 patients with probable small fiber neuropathy (SFN) underwent two adjacent skin biopsies at the distal leg processed by IF and BFI technique. Agreement between IENFD pairs obtained by each method was assessed by Bland-Altman testing. The area under the curve of the receiving operating characteristics (ROC) curves was used to compare the discrimination ability. The diagnostic judgment was based on sex and age-adjusted normative values. IF and BFI showed good correlation (r = 0.81), with a ratio of about 2: 1 and a mean difference of 5.5 +/- 3.0 IENF per millimeter between paired measures, as demonstrated by linear regression and Bland-Altman test analyses. The square root transformation confirmed a Poisson distribution of the data and a fixed bias between IF and BFI measurements. The ROC curves analysis demonstrated a striking overlap between IF and BFI (0.83 and 0.82; p = 0.72). The diagnosis of SFN disagreed in only 6.7% of cases when the judgment was based on a difference of > 1 IENF from 5% cut-off value. IF and BFI showed comparable diagnostic efficiency when referred to appropriate normative reference values.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [11] Bright-Field Microscopy of Transparent Objects: A Ray Tracing Approach
    Khitrin, Anatoly K.
    Petruccelli, Jonathan C.
    Model, Michael A.
    MICROSCOPY AND MICROANALYSIS, 2017, 23 (06) : 1116 - 1120
  • [12] Optical sectioning of unlabeled samples using bright-field microscopy
    Gutierrez-Medina, Braulio
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2022, 119 (14)
  • [13] Multistage morphological segmentation of bright-field and fluorescent microscopy images
    Korzynska, A.
    Iwanowski, M.
    OPTO-ELECTRONICS REVIEW, 2012, 20 (02) : 174 - 186
  • [14] Counting unstained, confluent cells by modified bright-field microscopy
    Drey, L. Louis
    Graber, Michael C.
    Bieschke, Jan
    BIOTECHNIQUES, 2013, 55 (01) : 28 - +
  • [15] DNA Comet Giemsa Staining for Conventional Bright-Field Microscopy
    Osipov, Andreyan
    Arkhangelskaya, Ekaterina
    Vinokurov, Alexei
    Smetanina, Nadezhda
    Zhavoronkov, Alex
    Klokov, Dmitry
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2014, 15 (04) : 6086 - 6095
  • [16] Theory of bright-field scanning transmission electron microscopy for tomography
    Levine, ZH
    JOURNAL OF APPLIED PHYSICS, 2005, 97 (03)
  • [17] MEMS ENDOMICROSCOPE FOR SIMULTANEOUS BRIGHT-FIELD MICROSCOPY AND OPTICAL COHERENCE TOMOGRAPHY
    Blattmann, M.
    Kretschmer, S.
    Thiele, S.
    Zappe, H.
    Herkommer, A.
    Seifert, A.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 216 - 219
  • [18] APPLICATION OF HILBERT TRANSFORM IN ELECTRON-MICROSCOPY .1. BRIGHT-FIELD MICROSCOPY
    MISELL, DL
    GREENAWAY, AH
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1974, 7 (06) : 832 - 855
  • [19] Multispectral intravital microscopy for simultaneous bright-field and fluorescence imaging of the microvasculature
    Janssen B.G.H.
    Najiminaini M.
    Zhang Y.M.
    Omidi P.
    Carson J.J.L.
    Applied Microscopy, 2021, 51 (01)
  • [20] MEASUREMENT UNCERTAINTIES ASSOCIATED WITH THE USE OF BRIGHT-FIELD AND FLUORESCENCE MICROSCOPY IN THE MICROCIRCULATION
    GRETZ, JE
    DULING, BR
    MICROVASCULAR RESEARCH, 1995, 49 (01) : 134 - 140