Epidermal innervation morphometry by immunofluorescence and bright-field microscopy

被引:28
|
作者
Nolano, Maria [1 ]
Biasiotta, Antonella [2 ]
Lombardi, Raffaella [3 ,4 ]
Provitera, Vincenzo [1 ]
Stancanelli, Annamaria [1 ]
Caporaso, Giuseppe [1 ]
Santoro, Lucio [5 ]
Merkies, Ingemar S. J. [6 ]
Truini, Andrea [2 ]
Porretta-Serapiglia, Carla [3 ,4 ]
Cazzato, Daniele [3 ,4 ]
Dacci, Patrizia [3 ,4 ]
Vitale, Dino F. [1 ]
Lauria, Giuseppe [3 ,4 ]
机构
[1] Salvatore Maugeri Fdn, Inst Telese Terme BN, Telese Terme, BN, Italy
[2] Univ Roma La Sapienza, Dept Neurol & Psychiat, I-00185 Rome, Italy
[3] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Neurol Unit 3, I-20133 Milan, Italy
[4] Ist Nazl Neurol Carlo Besta, IRCCS Fdn, Skin Biopsy Peripheral Neuropathy & Neuropath Pai, I-20133 Milan, Italy
[5] Univ Naples Federico II, Dept Neurosci Reprod Sci & Odontostomatol, Naples, Italy
[6] Spaarne Hosp, Dept Neurol, Hoofddorp, Netherlands
关键词
immunofluorescence; immunohistochemistry; intraepidermal nerve fiber; painful neuropathy; skin biopsy; NERVE-FIBER DENSITY; SKIN BIOPSY; NEUROPATHIES;
D O I
10.1111/jns.12146
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We investigated the agreement between simple indirect immunofluorescence (IF) and bright-field immunohistochemistry (BFI) on free-floating sections for intraepidermal nerve fiber density (IENFD) quantification. Fifty-five healthy subjects and 63 patients with probable small fiber neuropathy (SFN) underwent two adjacent skin biopsies at the distal leg processed by IF and BFI technique. Agreement between IENFD pairs obtained by each method was assessed by Bland-Altman testing. The area under the curve of the receiving operating characteristics (ROC) curves was used to compare the discrimination ability. The diagnostic judgment was based on sex and age-adjusted normative values. IF and BFI showed good correlation (r = 0.81), with a ratio of about 2: 1 and a mean difference of 5.5 +/- 3.0 IENF per millimeter between paired measures, as demonstrated by linear regression and Bland-Altman test analyses. The square root transformation confirmed a Poisson distribution of the data and a fixed bias between IF and BFI measurements. The ROC curves analysis demonstrated a striking overlap between IF and BFI (0.83 and 0.82; p = 0.72). The diagnosis of SFN disagreed in only 6.7% of cases when the judgment was based on a difference of > 1 IENF from 5% cut-off value. IF and BFI showed comparable diagnostic efficiency when referred to appropriate normative reference values.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [1] COMPARATIVE MORPHOMETRY OF EPIDERMAL INNERVATION DENSITY BY IMMUNOFLUORESCENCE AND BRIGHT-FIELD MICROSCOPY
    Nolano, M.
    Lombardi, R.
    Biasiotta, A.
    Provitera, V
    Stancanelli, A.
    Porretta-Serapiglia, C.
    Truini, A.
    Lauria, G.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2013, 18 : 23 - 23
  • [2] QUANTIFICATION OF EPIDERMAL NERVES BY IMMUNOFLUORESCENCE AND BRIGHT-FIELD MICROSCOPY: A COMPARATIVE STUDY
    Nolano, M.
    Lombardi, R.
    Biasiotta, A.
    Provitera, V
    Stancanelli, A.
    Porretta-Serapiglia, C.
    Truini, A.
    Lauria, G.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2013, 18 : 81 - 81
  • [3] BRIGHT-FIELD MICROSCOPY OF BERYLLIUM
    GROTZKY, VK
    FRAIKOR, FJ
    JOURNAL OF THE LESS-COMMON METALS, 1968, 14 (02): : 244 - &
  • [4] BRIGHT-FIELD MICROSCOPY OF SEMITRANSPARENT OBJECTS
    STAGAMAN, G
    FORSYTH, JM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (05): : 648 - 659
  • [5] Metal-enhanced bright-field microscopy
    Sasikumar, Harish
    Varma, Manoj
    APPLIED OPTICS, 2020, 59 (32) : 9971 - 9977
  • [6] Automated focusing in bright-field microscopy for tuberculosis detection
    Osibote, O. A.
    Dendere, R.
    Krishnan, S.
    Douglas, T. S.
    JOURNAL OF MICROSCOPY, 2010, 240 (02) : 155 - 163
  • [7] DARK-FIELD MICROSCOPY OF TRANSPARENT OBJECTS WITH A BRIGHT-FIELD OBJECTIVE
    HARTMAN, AW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (03): : 502 - 503
  • [8] Theory of bright-field scanning transmission electron microscopy for tomography
    Levine, Zachary H.
    Journal of Applied Physics, 2005, 97 (03):
  • [9] THE USE OF BRIGHT-FIELD MICROSCOPY IN EVALUATING BOVINE ACROSOME REACTION
    CHRISTENSEN, P
    WHITFIELD, CH
    PARKINSON, TJ
    THERIOGENOLOGY, 1994, 42 (04) : 655 - 662
  • [10] Apparatus and method to recover the Mueller matrix in bright-field microscopy
    Obando-Vasquez, Sofia
    Doblas, Ana
    Trujillo, Carlos
    AMERICAN JOURNAL OF PHYSICS, 2022, 90 (09) : 702 - 714