Simultaneous removal of cadmium and turbidity in contaminated soil-washing water by DAF and electroflotation

被引:13
|
作者
Park, J [1 ]
Jung, Y
Han, M
Lee, S
机构
[1] Seoul Natl Univ, Sch Civ Urban & Geosyst Engn, Seoul 151742, South Korea
[2] Chosun Univ, Sch Environm Engn, Kwangju 501759, South Korea
关键词
cadmium; coflotation; dissolved air flotation; electroflotation; turbidity;
D O I
10.2166/wst.2002.0742
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal of cadmium and turbidity from contaminated soil-washing water was studied by dissolved air flotation (DAF) and electroflotation at laboratory scale by using sodium lauryl sulfate (SLS) as an anionic surfactant, and calcium hydroxide (Ca(OH)(2)) as a coagulant. Using DAF, and in the presence of SLS or Ca(OH)(2) the maximum recovery rate of cadmium obtained at a stoichiometric cadmium to collector and coagulant ratio of 1:4.5 was 51.1% and 80.8%, while the removal rate of turbidity was 18.4% and 19.2%. However, satisfactory cadmium and turbidity removal was not obtained by DAF Much more significant removal of cadmium (100%, not detected in the residual) and turbidity (95.7%) was obtained by electroflotation using an aluminium metal plate as electrode, which generated hydroxide and aluminum ion. As a consequence, electroflotation is considered an effective method to separate cadmium and turbidity from contaminated soil-washing water. The electroflotation process may have practical applications for the removal of other hazardous metals from contaminated soil-washing water.
引用
收藏
页码:225 / 230
页数:6
相关论文
empty
未找到相关数据