DNA sensors to assess the effect of VKORC1 and CYP2C9 gene polymorphisms on warfarin dose requirement in Chinese patients with atrial fibrillation

被引:13
作者
Huang, Tao-Sheng [1 ]
Zhang, Ling [2 ]
He, Qiong [3 ]
Li, Yu-Bin [4 ]
Dai, Zhong-Li [5 ]
Zheng, Jian-Rui [6 ]
Cheng, Pei-Qi [7 ]
He, Yun-Shao [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Sch Med, 74 Zhongshan Rd 2, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 3, Dept Hematol, Guangzhou, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Pathol, Guangzhou, Guangdong, Peoples R China
[4] Linyi Peoples Hosp, Dept Vasc Surg, Shandong, Peoples R China
[5] Anhui Med Univ, Luan Affiliated Hosp, Dept Cardiol, Hefei, Anhui, Peoples R China
[6] Sun Yat Sen Univ, Affiliated Hosp 3, Dept Cardiol, Guangzhou, Guangdong, Peoples R China
[7] Southern Med Univ, Sch Biotechnol, Guangzhou, Guangdong, Peoples R China
关键词
Warfarin dosing; Electrochemical DNA sensor; Frequency; Atrial fibrillation; GLASSY-CARBON ELECTRODE; PHARMACOGENETIC ALGORITHM; AFRICAN-AMERICANS; KOREAN POPULATION; BIOSENSOR; VARIANTS; IMPACT; ASSOCIATION; GENOTYPE; ALLELE;
D O I
10.1007/s13246-016-0519-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The optimal dose of warfarin depends on polymorphisms in the VKORC1 (the vitamin K epoxide reductase complex subunit (1) and CYP2C9 (cytochrome P450 2C9) genes. To minimize the risk of adverse reactions, warfarin dosages should be adjusted according to results from rapid and simple monitoring methods. However, there are few pharmacogenetic-guided warfarin dosing algorithms that are based on large cohorts from the Chinese population, especially patients with atrial fibrillation. This study aimed to validate a pharmacogenetic-guided rapid electrochemical detection method used in a multicenter study. Three SNPs (CYP2C9* 2, * 3 and VKORC1 c.-1639G >A) were genotyped by electrochemical detection using a sandwich-type format that included a 3' short thiol capture probe and a 5' ferrocene-labeled signal probe. A total of 1285 samples from four clinical hospitals were evaluated. Concordance rates between the results from the electrochemical DNA biosensor and the sequencing test were 99.8%. The results for gene distribution showed that most Chinese patients had higher warfarin susceptibility because mutant-type and heterozygotes were present in the majority of subjects (99.4%) at locus c.-1639G > A. When the International Warfarin Pharmacogenetics Consortium algorithm was used to estimate therapeutic dosages for 362 patients with AF and the values were compared with their actual dosages, the results revealed that 56.9% were similar to actual dosages (within the 20% range). A novel electrochemical detection method of CYP2C9* 2, * 3 and VKORC1 c.-1639G > A alleles was evaluated. The warfarin dosing algorithm based on data gathered from a large patient cohort can facilitate the reasonable and effective use of warfarin in Chinese patients with AF.
引用
收藏
页码:249 / 258
页数:10
相关论文
共 64 条
  • [1] A novel electrochemical DNA biosensor based on poly-(5-amino-2-mercapto-1,3,4-thiadiazole) modified glassy carbon electrode for the determination of nitrofurantoin
    Aydogdu, Gozde
    Gunendi, Gulendem
    Zeybek, Derya Koyuncu
    Zeybek, Bulent
    Pekyardimci, Sule
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 197 : 211 - 219
  • [2] Allele and genotype frequencies of CYP2C9 in a Korean population
    Bae, JW
    Kim, HK
    Kim, JH
    Yang, SI
    Kim, MJ
    Jang, CG
    Park, YS
    Lee, SY
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2005, 60 (04) : 418 - 422
  • [3] Bress A, 2012, PHARMACOGENOMICS, V13, P1925, DOI [10.2217/PGS.12.164, 10.2217/pgs.12.164]
  • [4] Electrochemical DNA biosensor for human papillomavirus 16 detection in real samples
    Campos-Ferreira, Danielly S.
    Nascimento, Gustavo A.
    Souza, Elaine V. M.
    Souto-Maior, Maria A.
    Arruda, Mariana S.
    Zanforlin, Deborah M. L.
    Ekert, Marek H. F.
    Bruneska, Danyelly
    Lima-Filho, Jose L.
    [J]. ANALYTICA CHIMICA ACTA, 2013, 804 : 258 - 263
  • [5] A rapid DNA biosensor for the molecular diagnosis of infectious disease
    Chua, AngLim
    Yean, Chan Yean
    Ravichandran, Manickam
    Lim, BoonHuat
    Lalitha, Pattabhiraman
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (09) : 3825 - 3831
  • [6] An electrochemical DNA sensor for sequence-specific DNA recognization in a homogeneous solution
    Cui, Han-Feng
    Cheng, Lin
    Zhang, Jie
    Liu, Ronghua
    Zhang, Cheng
    Fan, Hao
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 56 : 124 - 128
  • [7] A polymorphism in the VKORC1 gene is associated with an interindividual variability in the dose-anticoagulant effect of warfarin
    D'Andrea, G
    D'Ambrosio, RL
    Di Perna, P
    Chetta, M
    Santacroce, R
    Brancaccio, V
    Grandone, E
    Margaglione, M
    [J]. BLOOD, 2005, 105 (02) : 645 - 649
  • [8] Aptamer based electrochemical assay for the determination of thrombin by using the amplification of the nanoparticles
    Ding, Caifeng
    Ge, Ying
    Lin, Jin-Ming
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (06) : 1290 - 1294
  • [9] Electrochemical immunoassay of hepatitis B surface antigen by the amplification of gold nanoparticles based on the nanoporous gold electrode
    Ding, Caifeng
    Li, Hui
    Hu, Kongcheng
    Lin, Jin-Ming
    [J]. TALANTA, 2010, 80 (03) : 1385 - 1391
  • [10] Electrochemical DNA Biosensor Based on a Tetrahedral Nanostructure Probe for the Detection of Avian Influenza A (H7N9) Virus
    Dong, Shibiao
    Zhao, Rongtao
    Zhu, Jiangong
    Lu, Xiao
    Li, Yang
    Qiu, Shaofu
    Jia, Leili
    Jiao, Xiong
    Song, Shiping
    Fan, Chunhai
    Hao, RongZhang
    Song, HongBin
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (16) : 8834 - 8842