A Prospective Randomized Study to Assess the Efficacy of Rate and Site of Atrial Pacing on Long-Term Development of Atrial Fibrillation

被引:9
作者
Lau, Chu-Pak [1 ]
Wang, Chun-Chieh [2 ]
Ngarmukos, Tachapong [3 ]
Kim, You-Ho
Kong, Chi-Woon [4 ]
Omar, Razali [5 ]
Sriratanasathavorn, Charn [6 ]
Munawar, Muhammad
Kam, Ruth [7 ]
Lee, Kathy Lf
Lau, Elizabeth Oi-Yan [8 ]
Tse, Hung-Fat
机构
[1] Univ Hong Kong, Inst Cardiovasc Sci & Med, Queen Mary Hosp, Hong Kong, Hong Kong, Peoples R China
[2] Chang Gung Mem Hosp, Linkou, Taiwan
[3] Mahidol Univ, Ramathibodi Hosp, Bangkok 10700, Thailand
[4] Taipei Vet Gen Hosp, Taipei, Taiwan
[5] Asan Med Ctr, Asan, South Korea
[6] Mahidol Univ, Siriraj Hosp, Bangkok 10700, Thailand
[7] Changi Gen Hosp, Singapore, Singapore
[8] St Jude Med, Hong Kong, Hong Kong, Peoples R China
关键词
atrial fibrillation; atrial overdrive pacing; atrial high rate episode; atrial fibrillation burden; pacemaker; site of atrial pacing; SICK SINUS SYNDROME; TRIAL; PREVENTION; PACEMAKER; TACHYARRHYTHMIAS; SUPPRESSION; BRADYCARDIA; SELECTION; OUTCOMES; RHYTHM;
D O I
10.1111/j.1540-8167.2009.01484.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Septal Pacing for Atrial Fibrillation Suppression Evaluation (SAFE) study is a single-blinded, parallel randomized designed multicenter study in pacemaker indicated patients with paroxysmal atrial fibrillation (AF). The objective is to evaluate whether the site of atrial pacing--conventional right atrial appendage versus low atrial septal-with or without atrial overdrive pacing will influence the development of persistent AF. The study will provide a definitive answer to whether a different atrial pacing site or the use of AF suppression pacing or both can give incremental antiarrhythmic benefit when one is implanting a device for a patient with a history of paroxysmal AF. (J Cardiovasc Electrophysiol, Vol. 20, pp. 1020-1025).
引用
收藏
页码:1020 / 1025
页数:6
相关论文
共 29 条
  • [1] Agresti A., 1990, Categorical data analysis, P79
  • [2] Adaptive bi-atrial pacing improves the maintenance of sinus rhythm
    Bacik, Bradley M.
    Muller, David
    Corbisiero, Raffaele
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (04): : 492 - 497
  • [3] Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: Results of a multicenter randomized trial
    Bailin, SJ
    Adler, S
    Giudici, M
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (08) : 912 - 917
  • [4] A new pacemaker algorithm for the treatment of atrial fibrillation - Results of the Atrial Dynamic Overdrive Pacing Trial (ADOPT)
    Carlson, MD
    Ip, J
    Messenger, J
    Beau, S
    Kalbfleisch, S
    Gervais, P
    Cameron, DA
    Duran, A
    Val-Mejias, J
    Mackall, J
    Gold, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (04) : 627 - 633
  • [5] No evidence of automatic atrial overdrive pacing efficacy on reduction of paroxysmal atrial fibrillation
    de Voogt, Willem
    van Hemel, Norbert
    de Vusser, Philip
    Mairesse, Georges H.
    van Mechelen, Rob
    Koistinen, Juhani
    van den Bos, Arjan
    Roose, Indrek
    Voitk, Jueri
    Yli-Mayry, Sinikka
    Stockman, Dirk
    El Allaf, Dia
    Tse, Hung-Fat
    Lau, Chu-Pak
    [J]. EUROPACE, 2007, 9 (09): : 798 - 804
  • [6] ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
    Epstein, Andrew E.
    DiMarco, John P.
    Ellenbogen, Kenneth A.
    Estes, N. A. Mark, III
    Freedman, Roger A.
    Gettes, Leonard S.
    Gillinov, A. Marc
    Gregoratos, Gabriel
    Hammill, Stephen C.
    Hayes, David L.
    Hlatky, Mark A.
    Newby, L. Kristin
    Page, Richard L.
    Schoenfeld, Mark H.
    Silka, Michael J.
    Stevenson, Lynne Warner
    Sweeney, Michael O.
    [J]. CIRCULATION, 2008, 117 (21) : E350 - E408
  • [7] Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke - Report of the atrial diagnostics ancillary study of the MOde Selection Trial (MOST)
    Glotzer, TV
    Hellkamp, AS
    Zimmerman, J
    Sweeney, MO
    Yee, R
    Marinchak, R
    Cook, J
    Paraschos, A
    Love, J
    Radoslovich, G
    Lee, KL
    Lamas, GA
    [J]. CIRCULATION, 2003, 107 (12) : 1614 - 1619
  • [8] GOLD M, 2006, EUROPACE, V8, P222
  • [9] Cardiovascular outcomes with atrial-based pacing compared with ventricular pacing - Meta-analysis of randomized trials, using individual patient data
    Healey, Jeffrey S.
    Toff, William D.
    Lamas, Gervasio A.
    Andersen, Henning R.
    Thorpe, Kevin E.
    Ellenbogen, Kenneth A.
    Lee, Kerry L.
    Skene, Allan M.
    Schron, Eleanor B.
    Skehan, J. Douglas
    Goldman, Lee
    Roberts, Robin S.
    Camm, A. John
    Yusuf, Salim
    Connolly, Stuart J.
    [J]. CIRCULATION, 2006, 114 (01) : 11 - 17
  • [10] Asymptomatic atrial fibrillation and stroke evaluation in pacemaker patients and the atrial fibrillation reduction atrial pacing trial (ASSERT)
    Holnloser, Stefan H.
    Capucci, Alessandro
    Fain, Eric
    Gold, Michael R.
    van Gelder, Isabelle C.
    Healey, Jeff
    Israel, Carsten W.
    Lau, Chu P.
    Morillo, Carlos
    Connolly, Stuart J.
    [J]. AMERICAN HEART JOURNAL, 2006, 152 (03) : 442 - 447