Matching PET and CT scans of the head and neck area: Development of method and validation

被引:34
作者
Klabbers, BM
de Munck, JC
Slotman, BJ
Langendijk, HA
de Bree, R
Hoekstra, OS
Boellaard, R
Lammertsma, AA
机构
[1] Vrije Univ Amsterdam, Dept Radiat Oncol, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Chem Phys & Informat, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Otolaryngol Head & Neck Surg, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Clin PET Ctr, Med Ctr, NL-1007 MB Amsterdam, Netherlands
关键词
PET; CT; image correlation; head and neck scans; registration validation;
D O I
10.1118/1.1508111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography (PET) provides important information on tumor biology, but lacks detailed anatomical information. Our aim in the present study was to develop and validate an automatic registration method for matching PET and CT scans of the head and neck. Three difficulties in achieving this goal are (1) nonrigid motions of the neck can hamper the use of automatic ridged body transformations; (2) emission scans contain too little anatomical information to apply standard image fusion methods; and (3) no objective way exists to quantify the quality of the match results. These problems are solved as follows: accurate and reproducible positioning of the patient was achieved by using a radiotherapy treatment mask. The proposed method makes use of the transmission rather than the emission scan. To obtain sufficient (anatomical) information for matching, two bed positions for the transmission scan were included in the protocol. A mutual information-based algorithm was used as a registration technique. PET and CT data were obtained in seven patients. Each patient had two CT scans and one PET scan. The datasets were used to estimate the consistency by matching PET to CT1, CT1 to CT2, and CT2 to PET using the full circle consistency test. It was found that using our method, consistency could be obtained of 4 mm and 1.3degrees on average. The PET voxels used for registration were 5.15 mm, so the errors compared quite favorably with the voxel size. Cropping the images (removing the scanner bed from images) did not improve the consistency of the algorithm. The transmission scan, however, could potentially be reduced to a single position using this approach. In conclusion, the represented algorithm and validation technique has several features that are attractive from both theoretical and practical point of view, it is a user-independent, automatic validation technique for matching CT and PET scans of the head and neck, which gives the opportunity to compare different image enhancements. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2230 / 2238
页数:9
相关论文
共 25 条
[1]   A FULLY-AUTOMATIC MULTIMODALITY IMAGE REGISTRATION ALGORITHM [J].
ARDEKANI, BA ;
BRAUN, M ;
HUTTON, BF ;
KANNO, I ;
IIDA, H .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (04) :615-623
[2]   PILOT-STUDY OF POSITRON EMISSION TOMOGRAPHY IN PATIENTS WITH ADVANCED HEAD AND NECK-CANCER RECEIVING RADIOTHERAPY AND CHEMOTHERAPY [J].
BERLANGIERI, SU ;
BRIZEL, DM ;
SCHER, RL ;
SCHIFTER, T ;
HAWK, TC ;
HAMBLEN, S ;
COLEMAN, RE ;
HOFFMAN, JM .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 1994, 16 (04) :340-346
[3]   CT and PET lung image registration and fusion in radiotherapy treatment planning using the chamfer-matching [J].
Cai, JL ;
Chu, JCH ;
Recine, D ;
Sharma, M ;
Nguyen, C ;
Rodebaugh, R ;
Saxena, VA ;
Ali, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04) :883-891
[4]   Registration of MR and SPECT without using external fiducial markers [J].
de Munck, JC ;
Verster, FC ;
Dubois, EA ;
Habraken, JBA ;
Boltjes, B ;
Claus, JJ ;
van Herk, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1255-1269
[5]   Spatial registration and normalization of images [J].
Friston, KJ ;
Ashburner, J ;
Frith, CD ;
Poline, JB ;
Heather, JD ;
Frackowiak, RSJ .
HUMAN BRAIN MAPPING, 1995, 3 (03) :165-189
[6]   Radiosynthesis of 3′-deoxy-3′-[18F]fluorothymidine:: [18F]FLT for imaging of cellular proliferation in vivo [J].
Grierson, JR ;
Shields, AF .
NUCLEAR MEDICINE AND BIOLOGY, 2000, 27 (02) :143-156
[7]  
Hoekstra CJ, 2002, CLIN CANCER RES, V8, P2109
[8]   Monitoring response to therapy in cancer using [18F]-2-fluouo-2-deoxy-D-glucose and positron emission tomography:: an overview of different analytical methods [J].
Hoekstra, CJ ;
Paglianiti, I ;
Hoekstra, OS ;
Smit, EF ;
Postmus, PE ;
Teule, GJJ ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (06) :731-743
[9]  
HOOGEMAN MS, 2000, 13 ICCR HEID GERM, P82
[10]   Set-up verification using portal imaging; review of current clinical practice [J].
Hurkmans, CW ;
Remeijer, P ;
Lebesque, JV ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :105-120