Optimized 4D Time-of-Flight MR Angiography Using Saturation Pulse

被引:5
作者
Shibukawa, Shuhei [1 ,2 ]
Nishio, Hiroaki [3 ]
Niwa, Tetsu [4 ]
Obara, Makoto [5 ]
Miyati, Tosiaki [2 ]
Hara, Takuya [4 ]
Imai, Yutaka [4 ]
Muro, Isao [1 ]
机构
[1] Tokai Univ Hosp, Dept Radiol, 143 Shimokasuya, Isehara, Kanagawa 2591143, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, Kanazawa, Ishikawa, Japan
[3] Gifu Prefectual Tajimi Hosp, Dept Radiol, Gifu, Japan
[4] Tokai Univ, Sch Med, Dept Radiol, Isehara, Kanagawa, Japan
[5] Healthcare, Philips Elect Japan, Shinagawa Ku, Tokyo, Japan
关键词
DIGITAL-SUBTRACTION-ANGIOGRAPHY; MAGNETIC-RESONANCE ANGIOGRAPHY; NEPHROGENIC SYSTEMIC FIBROSIS; ARTERIOVENOUS-MALFORMATION; DSA; SUPPRESSION; EXCITATION; RESOLUTION;
D O I
10.1002/jmri.25118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess arterial visibility on 4D time-of-flight (4D-TOF) by temporal magnetization transfer contrast pulse (t-MTC) and temporal tilted optimized nonsaturating excitation (t-TONE). 3D-TOF magnetic resonance angiography (MRA) is used for the noninvasive assessment of the intracranial arteries. However, it does not provide temporal information for diagnosing hemodynamics. To noninvasively obtain more detailed hemodynamics-related information, we developed a novel time-resolved MRA without the arterial spin labeling technique, termed 4D-TOF MRA using saturation pulse. Materials and Methods: On a 3.0T MRI, three techniques were compared to optimize the visibility of the arteries above the circle of Willis; 1) simple 4D-TOF, 2) 4D-TOF with t-MTC, and 3) 4D-TOF with t-MTC and t-TONE. Eight healthy volunteers were scanned with these three sequences. The contrast changes between the background tissue and the arteries in temporal phases were assessed and compared quantitatively and qualitatively. Results: The contrast between the background and the arteries for 4D-TOF with t-MTC and t-TONE was significantly higher than those for the other methods in delayed phases (P < 0.001). The qualitative assessment showed that 4D-TOF with t-MTC and with t-MTC and t-TONE provided better visualization of the intracranial artery than simple 4D-TOF (P < 0.001). Conclusion: 4D-TOF with t-TONE and t-MTC enabled observation of the intracranial hemodynamics. Optimized 4D-TOF provides high-quality images without image subtraction, and good visibility of the intracranial arteries even in the prolonged observation time.
引用
收藏
页码:1320 / 1326
页数:7
相关论文
共 27 条
  • [1] IMPROVED MR-ANGIOGRAPHY - MAGNETIZATION-TRANSFER SUPPRESSION WITH VARIABLE FLIP ANGLE EXCITATION AND INCREASED RESOLUTION
    ATKINSON, D
    BRANTZAWADZKI, M
    GILLAN, G
    PURDY, D
    LAUB, G
    [J]. RADIOLOGY, 1994, 190 (03) : 890 - 894
  • [2] SIGNAL TARGETING WITH ALTERNATING RADIOFREQUENCY (STAR) SEQUENCES - APPLICATION TO MR-ANGIOGRAPHY
    EDELMAN, RR
    SIEWERT, B
    ADAMIS, M
    GAA, T
    LAUB, G
    WIELOPOLSKI, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) : 233 - 238
  • [3] Comparison of MR angiography and conventional anglography in the investigation of intracranial arteriovenous malformations and aneurysms in children
    Fasulakis, S
    Andronikou, S
    [J]. PEDIATRIC RADIOLOGY, 2003, 33 (06) : 378 - 384
  • [4] Gadolinium - a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?
    Grobner, T
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (04) : 1104 - 1108
  • [5] Cerebral arteriovenous malformation: Spetzler-Martin classification at subsecond-temporal-resolution four-dimensional MR angiography compared with that at DSA
    Hadizadeh, Dariusch R.
    von Falkenhausen, Marcus
    Gieseke, Juergen
    Meyer, Bernhard
    Urbach, Horst
    Hoogeveen, Romhild
    Schild, Hans H.
    Willinek, Winfried A.
    [J]. RADIOLOGY, 2008, 246 (01) : 205 - 213
  • [6] INTRACRANIAL VASCULAR STENOSIS AND OCCLUSION - EVALUATION WITH 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    HEISERMAN, JE
    DRAYER, BP
    KELLER, PJ
    FRAM, EK
    [J]. RADIOLOGY, 1992, 185 (03) : 667 - 673
  • [7] Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula
    Jang, Jinhee
    Schmitt, Peter
    Kim, Bom-yi
    Choi, Hyun Seok
    Jung, So-Lyung
    Ahn, Kook-Jin
    Kim, Inseong
    Paek, Munyoung
    Kim, Bum-soo
    [J]. NEURORADIOLOGY, 2014, 56 (04) : 305 - 314
  • [8] QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING
    KIM, SG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) : 293 - 301
  • [9] Time-Resolved Angiography Using InfLow Subtraction (TRAILS)
    Kopeinigg, Daniel
    Bammer, Roland
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 669 - 678
  • [10] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351